Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration

Kartikeya Murari, Wenxuan Liang, Yuying Zhang, Jiefeng Xi, Xingde Li

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Using an acousto-optic modulator that froze beam positions on frames captured by an ordinary CCD camera, we were able to calibrate the Lissajous scanning pattern on a fiber-optic nonlinear endomicroscope quickly and precisely.

Original languageEnglish (US)
Title of host publicationBiomedical Optics, BIOMED 2012
StatePublished - 2012
EventBiomedical Optics, BIOMED 2012 - Miami, FL, United States
Duration: Apr 28 2012May 2 2012

Other

OtherBiomedical Optics, BIOMED 2012
CountryUnited States
CityMiami, FL
Period4/28/125/2/12

Fingerprint

acousto-optics
CCD cameras
Calibration
modulators
fiber optics
scanning

ASJC Scopus subject areas

  • Biotechnology
  • Atomic and Molecular Physics, and Optics

Cite this

Murari, K., Liang, W., Zhang, Y., Xi, J., & Li, X. (2012). Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration. In Biomedical Optics, BIOMED 2012

Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration. / Murari, Kartikeya; Liang, Wenxuan; Zhang, Yuying; Xi, Jiefeng; Li, Xingde.

Biomedical Optics, BIOMED 2012. 2012.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Murari, K, Liang, W, Zhang, Y, Xi, J & Li, X 2012, Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration. in Biomedical Optics, BIOMED 2012. Biomedical Optics, BIOMED 2012, Miami, FL, United States, 4/28/12.
Murari K, Liang W, Zhang Y, Xi J, Li X. Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration. In Biomedical Optics, BIOMED 2012. 2012
Murari, Kartikeya ; Liang, Wenxuan ; Zhang, Yuying ; Xi, Jiefeng ; Li, Xingde. / Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration. Biomedical Optics, BIOMED 2012. 2012.
@inproceedings{6c83e6e6be3b434996f9608743f90028,
title = "Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration",
abstract = "Using an acousto-optic modulator that froze beam positions on frames captured by an ordinary CCD camera, we were able to calibrate the Lissajous scanning pattern on a fiber-optic nonlinear endomicroscope quickly and precisely.",
author = "Kartikeya Murari and Wenxuan Liang and Yuying Zhang and Jiefeng Xi and Xingde Li",
year = "2012",
language = "English (US)",
isbn = "9781557529428",
booktitle = "Biomedical Optics, BIOMED 2012",

}

TY - GEN

T1 - Lissajous scanning fiber-optic nonlinear endomicroscope with precise position calibration

AU - Murari, Kartikeya

AU - Liang, Wenxuan

AU - Zhang, Yuying

AU - Xi, Jiefeng

AU - Li, Xingde

PY - 2012

Y1 - 2012

N2 - Using an acousto-optic modulator that froze beam positions on frames captured by an ordinary CCD camera, we were able to calibrate the Lissajous scanning pattern on a fiber-optic nonlinear endomicroscope quickly and precisely.

AB - Using an acousto-optic modulator that froze beam positions on frames captured by an ordinary CCD camera, we were able to calibrate the Lissajous scanning pattern on a fiber-optic nonlinear endomicroscope quickly and precisely.

UR - http://www.scopus.com/inward/record.url?scp=84890672451&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890672451&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84890672451

SN - 9781557529428

BT - Biomedical Optics, BIOMED 2012

ER -