Laparoendoscopic single site nephrectomy with the SPIDER surgical system: Engineering advancements tested in a porcine model

Nelson Salas, Michael Gorin, Vladislav Gorbatiy, Scott M. Castle, Vincent G. Bird, Raymond J. Leveillee

Research output: Contribution to journalArticle

Abstract

Background and Purpose: The Single Port Instrument Delivery Extended Reach (SPIDER) surgical system was developed for true continuous instrument triangulation during laparoendoscopic single site (LESS) surgery. We present our initial preclinical experience with the SPIDER surgical system during renal surgery. Material and Methods: Bilateral laparoscopic nephrectomies were performed in a live adult porcine animal model using the SPIDER device. A standard surgical approach was used via direct video guidance. Results: The procedure was successfully performed without surgical error or complication. The SPIDER system proved easy to use with only a minimal learning curve. Intracorporeal surgical knots were tied without difficulty using this single site system. Conclusions: Our initial experience with the SPIDER surgical system during renal surgery is promising. SPIDER allows for true single port instrument triangulation offering a superior operative experience to currently available LESS surgical systems.

Original languageEnglish (US)
Pages (from-to)739-742
Number of pages4
JournalJournal of Endourology
Volume25
Issue number5
DOIs
StatePublished - May 1 2011
Externally publishedYes

Fingerprint

Nephrectomy
Swine
Kidney
Medical Errors
Learning Curve
Animal Models
Equipment and Supplies

ASJC Scopus subject areas

  • Urology

Cite this

Laparoendoscopic single site nephrectomy with the SPIDER surgical system : Engineering advancements tested in a porcine model. / Salas, Nelson; Gorin, Michael; Gorbatiy, Vladislav; Castle, Scott M.; Bird, Vincent G.; Leveillee, Raymond J.

In: Journal of Endourology, Vol. 25, No. 5, 01.05.2011, p. 739-742.

Research output: Contribution to journalArticle

Salas, Nelson ; Gorin, Michael ; Gorbatiy, Vladislav ; Castle, Scott M. ; Bird, Vincent G. ; Leveillee, Raymond J. / Laparoendoscopic single site nephrectomy with the SPIDER surgical system : Engineering advancements tested in a porcine model. In: Journal of Endourology. 2011 ; Vol. 25, No. 5. pp. 739-742.
@article{4bbbbded179a48aa89216046ac710f39,
title = "Laparoendoscopic single site nephrectomy with the SPIDER surgical system: Engineering advancements tested in a porcine model",
abstract = "Background and Purpose: The Single Port Instrument Delivery Extended Reach (SPIDER) surgical system was developed for true continuous instrument triangulation during laparoendoscopic single site (LESS) surgery. We present our initial preclinical experience with the SPIDER surgical system during renal surgery. Material and Methods: Bilateral laparoscopic nephrectomies were performed in a live adult porcine animal model using the SPIDER device. A standard surgical approach was used via direct video guidance. Results: The procedure was successfully performed without surgical error or complication. The SPIDER system proved easy to use with only a minimal learning curve. Intracorporeal surgical knots were tied without difficulty using this single site system. Conclusions: Our initial experience with the SPIDER surgical system during renal surgery is promising. SPIDER allows for true single port instrument triangulation offering a superior operative experience to currently available LESS surgical systems.",
author = "Nelson Salas and Michael Gorin and Vladislav Gorbatiy and Castle, {Scott M.} and Bird, {Vincent G.} and Leveillee, {Raymond J.}",
year = "2011",
month = "5",
day = "1",
doi = "10.1089/end.2010.0608",
language = "English (US)",
volume = "25",
pages = "739--742",
journal = "Journal of Endourology",
issn = "0892-7790",
publisher = "Mary Ann Liebert Inc.",
number = "5",

}

TY - JOUR

T1 - Laparoendoscopic single site nephrectomy with the SPIDER surgical system

T2 - Engineering advancements tested in a porcine model

AU - Salas, Nelson

AU - Gorin, Michael

AU - Gorbatiy, Vladislav

AU - Castle, Scott M.

AU - Bird, Vincent G.

AU - Leveillee, Raymond J.

PY - 2011/5/1

Y1 - 2011/5/1

N2 - Background and Purpose: The Single Port Instrument Delivery Extended Reach (SPIDER) surgical system was developed for true continuous instrument triangulation during laparoendoscopic single site (LESS) surgery. We present our initial preclinical experience with the SPIDER surgical system during renal surgery. Material and Methods: Bilateral laparoscopic nephrectomies were performed in a live adult porcine animal model using the SPIDER device. A standard surgical approach was used via direct video guidance. Results: The procedure was successfully performed without surgical error or complication. The SPIDER system proved easy to use with only a minimal learning curve. Intracorporeal surgical knots were tied without difficulty using this single site system. Conclusions: Our initial experience with the SPIDER surgical system during renal surgery is promising. SPIDER allows for true single port instrument triangulation offering a superior operative experience to currently available LESS surgical systems.

AB - Background and Purpose: The Single Port Instrument Delivery Extended Reach (SPIDER) surgical system was developed for true continuous instrument triangulation during laparoendoscopic single site (LESS) surgery. We present our initial preclinical experience with the SPIDER surgical system during renal surgery. Material and Methods: Bilateral laparoscopic nephrectomies were performed in a live adult porcine animal model using the SPIDER device. A standard surgical approach was used via direct video guidance. Results: The procedure was successfully performed without surgical error or complication. The SPIDER system proved easy to use with only a minimal learning curve. Intracorporeal surgical knots were tied without difficulty using this single site system. Conclusions: Our initial experience with the SPIDER surgical system during renal surgery is promising. SPIDER allows for true single port instrument triangulation offering a superior operative experience to currently available LESS surgical systems.

UR - http://www.scopus.com/inward/record.url?scp=79957589837&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79957589837&partnerID=8YFLogxK

U2 - 10.1089/end.2010.0608

DO - 10.1089/end.2010.0608

M3 - Article

C2 - 21388244

AN - SCOPUS:79957589837

VL - 25

SP - 739

EP - 742

JO - Journal of Endourology

JF - Journal of Endourology

SN - 0892-7790

IS - 5