Interventional MRI: Tapering improves the distal sensitivity of the loopless antenna

Di Qian, AbdEl Monem M El-Sharkawy, Ergin Atalar, Paul A Bottomley

Research output: Contribution to journalArticle

Abstract

The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI.

Original languageEnglish (US)
Pages (from-to)797-802
Number of pages6
JournalMagnetic Resonance in Medicine
Volume63
Issue number3
DOIs
StatePublished - Mar 2010

Fingerprint

Interventional Magnetic Resonance Imaging
Signal-To-Noise Ratio
Electromagnetic Phenomena
Aorta

Keywords

  • Interventional MRI
  • Intravascular MRI
  • Loopless antenna
  • MRI detectors
  • Signal-to-noise ratio

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Interventional MRI : Tapering improves the distal sensitivity of the loopless antenna. / Qian, Di; El-Sharkawy, AbdEl Monem M; Atalar, Ergin; Bottomley, Paul A.

In: Magnetic Resonance in Medicine, Vol. 63, No. 3, 03.2010, p. 797-802.

Research output: Contribution to journalArticle

Qian, Di ; El-Sharkawy, AbdEl Monem M ; Atalar, Ergin ; Bottomley, Paul A. / Interventional MRI : Tapering improves the distal sensitivity of the loopless antenna. In: Magnetic Resonance in Medicine. 2010 ; Vol. 63, No. 3. pp. 797-802.
@article{00ddda083b0d4d8a83f2741bccb086ba,
title = "Interventional MRI: Tapering improves the distal sensitivity of the loopless antenna",
abstract = "The {"}loopless antenna{"} is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or {"}whip{"}. A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400{\%} increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI.",
keywords = "Interventional MRI, Intravascular MRI, Loopless antenna, MRI detectors, Signal-to-noise ratio",
author = "Di Qian and El-Sharkawy, {AbdEl Monem M} and Ergin Atalar and Bottomley, {Paul A}",
year = "2010",
month = "3",
doi = "10.1002/mrm.22152",
language = "English (US)",
volume = "63",
pages = "797--802",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Interventional MRI

T2 - Tapering improves the distal sensitivity of the loopless antenna

AU - Qian, Di

AU - El-Sharkawy, AbdEl Monem M

AU - Atalar, Ergin

AU - Bottomley, Paul A

PY - 2010/3

Y1 - 2010/3

N2 - The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI.

AB - The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI.

KW - Interventional MRI

KW - Intravascular MRI

KW - Loopless antenna

KW - MRI detectors

KW - Signal-to-noise ratio

UR - http://www.scopus.com/inward/record.url?scp=77649176475&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77649176475&partnerID=8YFLogxK

U2 - 10.1002/mrm.22152

DO - 10.1002/mrm.22152

M3 - Article

C2 - 20187186

AN - SCOPUS:77649176475

VL - 63

SP - 797

EP - 802

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -