TY - JOUR
T1 - Internal mouthpiece designs as a future perspective for enhanced aerosol deposition. Comparative results for aerosol chemotherapy and aerosol antibiotics
AU - Zarogoulidis, Paul
AU - Petridis, Dimitris
AU - Ritzoulis, Christos
AU - Darwiche, Kaid
AU - Kioumis, Ioannis
AU - Porpodis, Konstantinos
AU - Spyratos, Dionysios
AU - Hohenforst-Schmidt, Wolfgang
AU - Yarmus, Lonny
AU - Huang, Haidong
AU - Li, Qiang
AU - Freitag, Lutz
AU - Zarogoulidis, Konstantinos
PY - 2013
Y1 - 2013
N2 - Background In an effort to identify factors producing a finest mist from Jet-Nebulizers we designed 2 mouthpieces with 4 different internal designs and 1-3 compartments. Materials and methods Ten different drugs previous used with their "ideal" combination of jet-nebulizer, residual-cup and loading were used. For each drug the mass median aerodynamic diameter size had been established along with their "ideal" combination. Results For both mouthpiece, drug was the most important factor due the high F-values (F large = 251.7, p < 0.001 and Fsmall = 60.1, p < 0.001) produced. The design affected the droplet size but only for large mouthpiece (Flarge = 5.99, p = 0.001, Fsmall = 1.72, p = 0.178). Cross designs create the smallest droplets (2.271) so differing from the other designs whose mean droplets were greater and equal ranging between 2.39 and 2.447. The number of compartments in the two devices regarding the 10 drugs was found not statistically significant (p-values 0.768 and 0.532 respectively). Interaction effects between drugs and design were statistically significant for both devices (Flarge = 8.87, p < 0.001, Fsmall = 5.33, p < 0.001). Conclusion Based on our experiment we conclude that further improvement of the drugs intended for aerosol production is needed. In addition, the mouthpiece design and size play an important role in further enhancing the fine mist production and therefore further experimentation is needed.
AB - Background In an effort to identify factors producing a finest mist from Jet-Nebulizers we designed 2 mouthpieces with 4 different internal designs and 1-3 compartments. Materials and methods Ten different drugs previous used with their "ideal" combination of jet-nebulizer, residual-cup and loading were used. For each drug the mass median aerodynamic diameter size had been established along with their "ideal" combination. Results For both mouthpiece, drug was the most important factor due the high F-values (F large = 251.7, p < 0.001 and Fsmall = 60.1, p < 0.001) produced. The design affected the droplet size but only for large mouthpiece (Flarge = 5.99, p = 0.001, Fsmall = 1.72, p = 0.178). Cross designs create the smallest droplets (2.271) so differing from the other designs whose mean droplets were greater and equal ranging between 2.39 and 2.447. The number of compartments in the two devices regarding the 10 drugs was found not statistically significant (p-values 0.768 and 0.532 respectively). Interaction effects between drugs and design were statistically significant for both devices (Flarge = 8.87, p < 0.001, Fsmall = 5.33, p < 0.001). Conclusion Based on our experiment we conclude that further improvement of the drugs intended for aerosol production is needed. In addition, the mouthpiece design and size play an important role in further enhancing the fine mist production and therefore further experimentation is needed.
KW - Aerosol
KW - Designs
KW - Mouthpiece
UR - http://www.scopus.com/inward/record.url?scp=84886722925&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84886722925&partnerID=8YFLogxK
U2 - 10.1016/j.ijpharm.2013.09.004
DO - 10.1016/j.ijpharm.2013.09.004
M3 - Article
C2 - 24035789
AN - SCOPUS:84886722925
SN - 0378-5173
VL - 456
SP - 325
EP - 331
JO - International Journal of Pharmaceutics
JF - International Journal of Pharmaceutics
IS - 2
ER -