Interferon-γ release assays and tuberculin skin testing for diagnosis of latent tuberculosis infection in healthcare workers in the united states

Susan E. Dorman, Robert Belknap, Edward A. Graviss, Randall Reves, Neil Schluger, Paul Weinfurter, Yaping Wang, Wendy Cronin, Yael Hirsch-Moverman, Larry D. Teeter, Matthew Parker, Denise O. Garrett, Charles L. Daley

Research output: Contribution to journalArticlepeer-review

166 Scopus citations

Abstract

Rationale: IFN-γ release assays (IGRAs) are alternatives to tuberculin skin testing (TST) for diagnosis of latent tuberculosis infection. Limited data suggest IGRAs may not perform well for serial testing of healthcare workers (HCWs). Objectives: Determine the performance characteristics of IGRAs versus TST for serial testing of HCWs. Methods: A longitudinal study involving 2,563 HCWs undergoing occupational tuberculosis screening at four healthcare institutions in the United States, where the average tuberculosis case rate ranged from 4 to 9 per 100,000 persons. QuantiFERON-TB Gold In-Tube (QFTGIT), T-SPOT.TB (T-SPOT), and TST were performed at baseline and every 6 months for 18 months between February 2008 and March 2011. Measurements and Main Results: A total of 2,418 HCWs completed baseline testing, which was positive for 125 (5.2%) by TST, 118 (4.9%) by QFT-GIT, and 144 (6.0%) by T-SPOT. A baseline positive TST with negative IGRAs was associated with bacillus Calmette-Gúerin (BCG) vaccination (odds ratio: 25.1 [95% confidence interval: 15.5, 40.5] vs. no BCG). Proportions of participants with test conversion during the study period were 138 of 2,263 (6.1%) for QFT-GIT, 177 of 2,137 (8.3%) for T-SPOT, and 21 of 2,293 (0.9%) for TST (P < 0.001 for QFT-GIT vs. TST and for T-SPOT vs. TST; P = 0.005 for QFT-GIT vs. T-SPOT). Of the QFT-GIT and T-SPOT converters, 81 of 106 (76.4%) and 91 of 118 (77.1%), respectively, were negative when retested 6 months later. There was negative/positive discordance for 15 of 170 (8.8%) participants by QFT-GIT and for 19 of 151 (12.6%) by T-SPOT when blood was drawn 2 weeks later. Conclusions: Most conversions among HCWs in low TB incidence settings appear to be false positives, and these occurred six to nine times more frequently with IGRAs than TST; repeat testing of apparent converters is warranted.

Original languageEnglish (US)
Pages (from-to)77-87
Number of pages11
JournalAmerican journal of respiratory and critical care medicine
Volume189
Issue number1
DOIs
StatePublished - Jan 1 2014
Externally publishedYes

Keywords

  • False positive
  • QuantiFERON
  • Screening
  • T-SPOT.TB

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Critical Care and Intensive Care Medicine

Fingerprint

Dive into the research topics of 'Interferon-γ release assays and tuberculin skin testing for diagnosis of latent tuberculosis infection in healthcare workers in the united states'. Together they form a unique fingerprint.

Cite this