Inflow-based vascular-space-occupancy (iVASO) MRI

Jun Hua, Qin Qin, Manus J. Donahue, Jinyuan Zhou, James J Pekar, Peter C Van Zijl

Research output: Contribution to journalArticle

Abstract

Vascular-space-occupancy (VASO) MRI, a blood nulling approach for assessing changes in cerebral blood volume (CBV), is hampered by low signal-to-noise ratio (SNR) because only 10-20% of tissue signal is recovered when using nonselective inversion for blood nulling. A new approach, called inflow-VASO (iVASO), is introduced in which only blood flowing into the slice has experienced inversion, thereby keeping tissue and cerebrospinal fluid (CSF) signal in the slice maximal and reducing CSF partial volume effects. SNR increases of 198% ± 12% and 334% ± 9% (mean ± SD, n = 7) with respect to VASO were found at TR values of 5s and 2s, respectively. When using inflow approaches, data interpretation is complicated by the fact that signal changes are affected by vascular transit times. An optimal TR-range (1.5-2.5s) was derived in which the iVASO response during activation predominantly reflects arterial/arteriolar CBV (CBV a) changes. In this TR-range, perfusion contributions to the signal change are negligible because arterial label has not yet undergone capillary exchange, and arterial and precapillary blood signals are nulled. For TR = 2s, the iVASO signal change upon visual stimulation corresponded to a CBV a increase of 58% ± 7%, in agreement with arteriolar CBV changes previously reported. The onset of the hemodynamic response for iVASO occurred 1.2 ± 0.5s (n = 7) faster than for conventional VASO. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc.

Original languageEnglish (US)
Pages (from-to)40-56
Number of pages17
JournalMagnetic Resonance in Medicine
Volume66
Issue number1
DOIs
StatePublished - Jul 2011

Fingerprint

Blood Vessels
Signal-To-Noise Ratio
Cerebrospinal Fluid
Photic Stimulation
Perfusion
Hemodynamics
Cerebral Blood Volume

Keywords

  • arterial
  • arteriolar
  • CBV
  • cerebral blood volume
  • CNR
  • fMRI
  • hemodynamic response
  • inflow VASO
  • iVASO
  • SNR
  • transit time
  • vascular space occupancy
  • VASO

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Inflow-based vascular-space-occupancy (iVASO) MRI. / Hua, Jun; Qin, Qin; Donahue, Manus J.; Zhou, Jinyuan; Pekar, James J; Van Zijl, Peter C.

In: Magnetic Resonance in Medicine, Vol. 66, No. 1, 07.2011, p. 40-56.

Research output: Contribution to journalArticle

@article{57a608fbf70942d5b9bae84bda05d770,
title = "Inflow-based vascular-space-occupancy (iVASO) MRI",
abstract = "Vascular-space-occupancy (VASO) MRI, a blood nulling approach for assessing changes in cerebral blood volume (CBV), is hampered by low signal-to-noise ratio (SNR) because only 10-20{\%} of tissue signal is recovered when using nonselective inversion for blood nulling. A new approach, called inflow-VASO (iVASO), is introduced in which only blood flowing into the slice has experienced inversion, thereby keeping tissue and cerebrospinal fluid (CSF) signal in the slice maximal and reducing CSF partial volume effects. SNR increases of 198{\%} ± 12{\%} and 334{\%} ± 9{\%} (mean ± SD, n = 7) with respect to VASO were found at TR values of 5s and 2s, respectively. When using inflow approaches, data interpretation is complicated by the fact that signal changes are affected by vascular transit times. An optimal TR-range (1.5-2.5s) was derived in which the iVASO response during activation predominantly reflects arterial/arteriolar CBV (CBV a) changes. In this TR-range, perfusion contributions to the signal change are negligible because arterial label has not yet undergone capillary exchange, and arterial and precapillary blood signals are nulled. For TR = 2s, the iVASO signal change upon visual stimulation corresponded to a CBV a increase of 58{\%} ± 7{\%}, in agreement with arteriolar CBV changes previously reported. The onset of the hemodynamic response for iVASO occurred 1.2 ± 0.5s (n = 7) faster than for conventional VASO. Magn Reson Med, 2010. {\circledC} 2010 Wiley-Liss, Inc.",
keywords = "arterial, arteriolar, CBV, cerebral blood volume, CNR, fMRI, hemodynamic response, inflow VASO, iVASO, SNR, transit time, vascular space occupancy, VASO",
author = "Jun Hua and Qin Qin and Donahue, {Manus J.} and Jinyuan Zhou and Pekar, {James J} and {Van Zijl}, {Peter C}",
year = "2011",
month = "7",
doi = "10.1002/mrm.22775",
language = "English (US)",
volume = "66",
pages = "40--56",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Inflow-based vascular-space-occupancy (iVASO) MRI

AU - Hua, Jun

AU - Qin, Qin

AU - Donahue, Manus J.

AU - Zhou, Jinyuan

AU - Pekar, James J

AU - Van Zijl, Peter C

PY - 2011/7

Y1 - 2011/7

N2 - Vascular-space-occupancy (VASO) MRI, a blood nulling approach for assessing changes in cerebral blood volume (CBV), is hampered by low signal-to-noise ratio (SNR) because only 10-20% of tissue signal is recovered when using nonselective inversion for blood nulling. A new approach, called inflow-VASO (iVASO), is introduced in which only blood flowing into the slice has experienced inversion, thereby keeping tissue and cerebrospinal fluid (CSF) signal in the slice maximal and reducing CSF partial volume effects. SNR increases of 198% ± 12% and 334% ± 9% (mean ± SD, n = 7) with respect to VASO were found at TR values of 5s and 2s, respectively. When using inflow approaches, data interpretation is complicated by the fact that signal changes are affected by vascular transit times. An optimal TR-range (1.5-2.5s) was derived in which the iVASO response during activation predominantly reflects arterial/arteriolar CBV (CBV a) changes. In this TR-range, perfusion contributions to the signal change are negligible because arterial label has not yet undergone capillary exchange, and arterial and precapillary blood signals are nulled. For TR = 2s, the iVASO signal change upon visual stimulation corresponded to a CBV a increase of 58% ± 7%, in agreement with arteriolar CBV changes previously reported. The onset of the hemodynamic response for iVASO occurred 1.2 ± 0.5s (n = 7) faster than for conventional VASO. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc.

AB - Vascular-space-occupancy (VASO) MRI, a blood nulling approach for assessing changes in cerebral blood volume (CBV), is hampered by low signal-to-noise ratio (SNR) because only 10-20% of tissue signal is recovered when using nonselective inversion for blood nulling. A new approach, called inflow-VASO (iVASO), is introduced in which only blood flowing into the slice has experienced inversion, thereby keeping tissue and cerebrospinal fluid (CSF) signal in the slice maximal and reducing CSF partial volume effects. SNR increases of 198% ± 12% and 334% ± 9% (mean ± SD, n = 7) with respect to VASO were found at TR values of 5s and 2s, respectively. When using inflow approaches, data interpretation is complicated by the fact that signal changes are affected by vascular transit times. An optimal TR-range (1.5-2.5s) was derived in which the iVASO response during activation predominantly reflects arterial/arteriolar CBV (CBV a) changes. In this TR-range, perfusion contributions to the signal change are negligible because arterial label has not yet undergone capillary exchange, and arterial and precapillary blood signals are nulled. For TR = 2s, the iVASO signal change upon visual stimulation corresponded to a CBV a increase of 58% ± 7%, in agreement with arteriolar CBV changes previously reported. The onset of the hemodynamic response for iVASO occurred 1.2 ± 0.5s (n = 7) faster than for conventional VASO. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc.

KW - arterial

KW - arteriolar

KW - CBV

KW - cerebral blood volume

KW - CNR

KW - fMRI

KW - hemodynamic response

KW - inflow VASO

KW - iVASO

KW - SNR

KW - transit time

KW - vascular space occupancy

KW - VASO

UR - http://www.scopus.com/inward/record.url?scp=79959537805&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79959537805&partnerID=8YFLogxK

U2 - 10.1002/mrm.22775

DO - 10.1002/mrm.22775

M3 - Article

C2 - 21695719

AN - SCOPUS:79959537805

VL - 66

SP - 40

EP - 56

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -