Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites

María Jesús Cruz, J. R. Villalbí, M. Swanson, J. M. Pintó, M. J. Rodrigo, F. Morell

Research output: Contribution to journalArticle

Abstract

Background: Asthma attacks and mortality due to inhalation of soybean antigens in Barcelona, Spain have been well documented. A new control scheme was adopted in the city to avoid the emission and dispersion of soybean dust into the atmosphere during unloading. We studied soybean allergen emission during unloading and at 3 industrial sites and compared the results obtained. Methods: Over a period of 31 months, 628 paired air samples from 3 plants (A, B, C) involved in soybean manipulation in Barcelona harbor were collected. Samples were analyzed by a radiometric competitive inhibition assay (RCIA) and the enzyme-linked immunosorbent assay (ELISA). A Bland-Altman plot was used to compare the soybean concentrations measured by each assay. Results: The median values for the 628 samples were 5535 U/m3 (range, 370-18 416 751) for the RCIA and 9955 U/m3 (range, 400-22 349 059) for the ELISA. Plant A had the lowest emission levels and the lowest Spearman rank correlation coefficient (0.409). The correlation coefficients were 0.747 and 0.794 for plants B and C. Soybean aeroallergen concentrations differed by plant. The highest variability in values was seen for plant A, which had the lowest allergen concentrations. Conclusions: The competitive assays described are useful tools for the measurement of soybean allergen emission levels at industrial sites. These methods may be used to monitor unloading and the impact of environmental interventions.

Original languageEnglish (US)
Pages (from-to)443-448
Number of pages6
JournalJournal of Investigational Allergology and Clinical Immunology
Volume18
Issue number6
StatePublished - 2008
Externally publishedYes

Fingerprint

Soybeans
Allergens
Enzyme-Linked Immunosorbent Assay
Nonparametric Statistics
Dust
Atmosphere
Spain
Inhalation
Asthma
Air
Antigens
Mortality

Keywords

  • Aeroallergen
  • Asthma
  • Competitive inhibition assay
  • Emission
  • Risk
  • Soybean

ASJC Scopus subject areas

  • Immunology and Allergy
  • Immunology

Cite this

Cruz, M. J., Villalbí, J. R., Swanson, M., Pintó, J. M., Rodrigo, M. J., & Morell, F. (2008). Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites. Journal of Investigational Allergology and Clinical Immunology, 18(6), 443-448.

Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites. / Cruz, María Jesús; Villalbí, J. R.; Swanson, M.; Pintó, J. M.; Rodrigo, M. J.; Morell, F.

In: Journal of Investigational Allergology and Clinical Immunology, Vol. 18, No. 6, 2008, p. 443-448.

Research output: Contribution to journalArticle

Cruz, MJ, Villalbí, JR, Swanson, M, Pintó, JM, Rodrigo, MJ & Morell, F 2008, 'Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites', Journal of Investigational Allergology and Clinical Immunology, vol. 18, no. 6, pp. 443-448.
Cruz, María Jesús ; Villalbí, J. R. ; Swanson, M. ; Pintó, J. M. ; Rodrigo, M. J. ; Morell, F. / Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites. In: Journal of Investigational Allergology and Clinical Immunology. 2008 ; Vol. 18, No. 6. pp. 443-448.
@article{33c29bf8b628420c8f5938fbddcf869b,
title = "Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites",
abstract = "Background: Asthma attacks and mortality due to inhalation of soybean antigens in Barcelona, Spain have been well documented. A new control scheme was adopted in the city to avoid the emission and dispersion of soybean dust into the atmosphere during unloading. We studied soybean allergen emission during unloading and at 3 industrial sites and compared the results obtained. Methods: Over a period of 31 months, 628 paired air samples from 3 plants (A, B, C) involved in soybean manipulation in Barcelona harbor were collected. Samples were analyzed by a radiometric competitive inhibition assay (RCIA) and the enzyme-linked immunosorbent assay (ELISA). A Bland-Altman plot was used to compare the soybean concentrations measured by each assay. Results: The median values for the 628 samples were 5535 U/m3 (range, 370-18 416 751) for the RCIA and 9955 U/m3 (range, 400-22 349 059) for the ELISA. Plant A had the lowest emission levels and the lowest Spearman rank correlation coefficient (0.409). The correlation coefficients were 0.747 and 0.794 for plants B and C. Soybean aeroallergen concentrations differed by plant. The highest variability in values was seen for plant A, which had the lowest allergen concentrations. Conclusions: The competitive assays described are useful tools for the measurement of soybean allergen emission levels at industrial sites. These methods may be used to monitor unloading and the impact of environmental interventions.",
keywords = "Aeroallergen, Asthma, Competitive inhibition assay, Emission, Risk, Soybean",
author = "Cruz, {Mar{\'i}a Jes{\'u}s} and Villalb{\'i}, {J. R.} and M. Swanson and Pint{\'o}, {J. M.} and Rodrigo, {M. J.} and F. Morell",
year = "2008",
language = "English (US)",
volume = "18",
pages = "443--448",
journal = "Journal of Investigational Allergology and Clinical Immunology",
issn = "1018-9068",
publisher = "Esmon",
number = "6",

}

TY - JOUR

T1 - Immunoquantitative measurement of soybean aeroallergen emissions at industrial sites

AU - Cruz, María Jesús

AU - Villalbí, J. R.

AU - Swanson, M.

AU - Pintó, J. M.

AU - Rodrigo, M. J.

AU - Morell, F.

PY - 2008

Y1 - 2008

N2 - Background: Asthma attacks and mortality due to inhalation of soybean antigens in Barcelona, Spain have been well documented. A new control scheme was adopted in the city to avoid the emission and dispersion of soybean dust into the atmosphere during unloading. We studied soybean allergen emission during unloading and at 3 industrial sites and compared the results obtained. Methods: Over a period of 31 months, 628 paired air samples from 3 plants (A, B, C) involved in soybean manipulation in Barcelona harbor were collected. Samples were analyzed by a radiometric competitive inhibition assay (RCIA) and the enzyme-linked immunosorbent assay (ELISA). A Bland-Altman plot was used to compare the soybean concentrations measured by each assay. Results: The median values for the 628 samples were 5535 U/m3 (range, 370-18 416 751) for the RCIA and 9955 U/m3 (range, 400-22 349 059) for the ELISA. Plant A had the lowest emission levels and the lowest Spearman rank correlation coefficient (0.409). The correlation coefficients were 0.747 and 0.794 for plants B and C. Soybean aeroallergen concentrations differed by plant. The highest variability in values was seen for plant A, which had the lowest allergen concentrations. Conclusions: The competitive assays described are useful tools for the measurement of soybean allergen emission levels at industrial sites. These methods may be used to monitor unloading and the impact of environmental interventions.

AB - Background: Asthma attacks and mortality due to inhalation of soybean antigens in Barcelona, Spain have been well documented. A new control scheme was adopted in the city to avoid the emission and dispersion of soybean dust into the atmosphere during unloading. We studied soybean allergen emission during unloading and at 3 industrial sites and compared the results obtained. Methods: Over a period of 31 months, 628 paired air samples from 3 plants (A, B, C) involved in soybean manipulation in Barcelona harbor were collected. Samples were analyzed by a radiometric competitive inhibition assay (RCIA) and the enzyme-linked immunosorbent assay (ELISA). A Bland-Altman plot was used to compare the soybean concentrations measured by each assay. Results: The median values for the 628 samples were 5535 U/m3 (range, 370-18 416 751) for the RCIA and 9955 U/m3 (range, 400-22 349 059) for the ELISA. Plant A had the lowest emission levels and the lowest Spearman rank correlation coefficient (0.409). The correlation coefficients were 0.747 and 0.794 for plants B and C. Soybean aeroallergen concentrations differed by plant. The highest variability in values was seen for plant A, which had the lowest allergen concentrations. Conclusions: The competitive assays described are useful tools for the measurement of soybean allergen emission levels at industrial sites. These methods may be used to monitor unloading and the impact of environmental interventions.

KW - Aeroallergen

KW - Asthma

KW - Competitive inhibition assay

KW - Emission

KW - Risk

KW - Soybean

UR - http://www.scopus.com/inward/record.url?scp=57349115494&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57349115494&partnerID=8YFLogxK

M3 - Article

C2 - 19123435

AN - SCOPUS:57349115494

VL - 18

SP - 443

EP - 448

JO - Journal of Investigational Allergology and Clinical Immunology

JF - Journal of Investigational Allergology and Clinical Immunology

SN - 1018-9068

IS - 6

ER -