Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay

B. Wannamaker, L. Denio, W. E. Dodson, F. Dreifuss, C. Crosby, N. Santilli, P. Duffner, P. Ryan-Dudeck, C. Conboy, E. Ellis, C. N. Ou, V. Frawley, J. Ellis, Eileen P.G. Vining, J. Carrico, S. Tillson

Research output: Contribution to journalArticle

Abstract

We tested the precision and accuracy of the AccuLevel Phenobarbital Test, which reports whole-blood (fingerstick) results in plasma equivalent values, and compared these values with plasma results obtained using established methods. We conclude that the assay is precise, reliable, accurate for single tests, and is appropriate for use in offices, outpatient settings, and emergency rooms.

Original languageEnglish (US)
Pages (from-to)1215-1218
Number of pages4
JournalNeurology
Volume39
Issue number9
StatePublished - 1989

Fingerprint

Phenobarbital
Hospital Emergency Service
Outpatients
Blood
Plasma
Emergency

ASJC Scopus subject areas

  • Arts and Humanities (miscellaneous)
  • Clinical Neurology
  • Neuroscience(all)

Cite this

Wannamaker, B., Denio, L., Dodson, W. E., Dreifuss, F., Crosby, C., Santilli, N., ... Tillson, S. (1989). Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay. Neurology, 39(9), 1215-1218.

Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay. / Wannamaker, B.; Denio, L.; Dodson, W. E.; Dreifuss, F.; Crosby, C.; Santilli, N.; Duffner, P.; Ryan-Dudeck, P.; Conboy, C.; Ellis, E.; Ou, C. N.; Frawley, V.; Ellis, J.; Vining, Eileen P.G.; Carrico, J.; Tillson, S.

In: Neurology, Vol. 39, No. 9, 1989, p. 1215-1218.

Research output: Contribution to journalArticle

Wannamaker, B, Denio, L, Dodson, WE, Dreifuss, F, Crosby, C, Santilli, N, Duffner, P, Ryan-Dudeck, P, Conboy, C, Ellis, E, Ou, CN, Frawley, V, Ellis, J, Vining, EPG, Carrico, J & Tillson, S 1989, 'Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay', Neurology, vol. 39, no. 9, pp. 1215-1218.
Wannamaker B, Denio L, Dodson WE, Dreifuss F, Crosby C, Santilli N et al. Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay. Neurology. 1989;39(9):1215-1218.
Wannamaker, B. ; Denio, L. ; Dodson, W. E. ; Dreifuss, F. ; Crosby, C. ; Santilli, N. ; Duffner, P. ; Ryan-Dudeck, P. ; Conboy, C. ; Ellis, E. ; Ou, C. N. ; Frawley, V. ; Ellis, J. ; Vining, Eileen P.G. ; Carrico, J. ; Tillson, S. / Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay. In: Neurology. 1989 ; Vol. 39, No. 9. pp. 1215-1218.
@article{c4ccf172b39245ebadfb851ddfdeceac,
title = "Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay",
abstract = "We tested the precision and accuracy of the AccuLevel Phenobarbital Test, which reports whole-blood (fingerstick) results in plasma equivalent values, and compared these values with plasma results obtained using established methods. We conclude that the assay is precise, reliable, accurate for single tests, and is appropriate for use in offices, outpatient settings, and emergency rooms.",
author = "B. Wannamaker and L. Denio and Dodson, {W. E.} and F. Dreifuss and C. Crosby and N. Santilli and P. Duffner and P. Ryan-Dudeck and C. Conboy and E. Ellis and Ou, {C. N.} and V. Frawley and J. Ellis and Vining, {Eileen P.G.} and J. Carrico and S. Tillson",
year = "1989",
language = "English (US)",
volume = "39",
pages = "1215--1218",
journal = "Neurology",
issn = "0028-3878",
publisher = "Lippincott Williams and Wilkins",
number = "9",

}

TY - JOUR

T1 - Immunochromatographic measurement of phenobarbital in whole blood with a non-instrumented assay

AU - Wannamaker, B.

AU - Denio, L.

AU - Dodson, W. E.

AU - Dreifuss, F.

AU - Crosby, C.

AU - Santilli, N.

AU - Duffner, P.

AU - Ryan-Dudeck, P.

AU - Conboy, C.

AU - Ellis, E.

AU - Ou, C. N.

AU - Frawley, V.

AU - Ellis, J.

AU - Vining, Eileen P.G.

AU - Carrico, J.

AU - Tillson, S.

PY - 1989

Y1 - 1989

N2 - We tested the precision and accuracy of the AccuLevel Phenobarbital Test, which reports whole-blood (fingerstick) results in plasma equivalent values, and compared these values with plasma results obtained using established methods. We conclude that the assay is precise, reliable, accurate for single tests, and is appropriate for use in offices, outpatient settings, and emergency rooms.

AB - We tested the precision and accuracy of the AccuLevel Phenobarbital Test, which reports whole-blood (fingerstick) results in plasma equivalent values, and compared these values with plasma results obtained using established methods. We conclude that the assay is precise, reliable, accurate for single tests, and is appropriate for use in offices, outpatient settings, and emergency rooms.

UR - http://www.scopus.com/inward/record.url?scp=0024436220&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024436220&partnerID=8YFLogxK

M3 - Article

C2 - 2671791

AN - SCOPUS:0024436220

VL - 39

SP - 1215

EP - 1218

JO - Neurology

JF - Neurology

SN - 0028-3878

IS - 9