Human touch vs. axillary digital thermometry for detection of neonatal hypothermia at community level

Siddharth Agarwal, Vani Sethi, Ravindra Mohan Pandey, Dimple Kondal

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

We examined the diagnostic accuracy of human touch (HT) method in assessing hypothermia against axillary digital thermometry (ADT) by a trained non-medical field investigator (who supervised activities of community health volunteers) in seven villages of Agra district, Uttar Pradesh, India. Body temperature of 148 newborns born between March and August 2005 was measured at four points in time for each enrolled newborn (within 48 h and on days 7, 30 and 60) by the field investigator under the axilla using a digital thermometer and by HT method using standard methodology. Total observations were 533. Hypothermia assessed by HT was in agreement with that assessed by ADT (<36.5°C) in 498 observations. Hypothermia assessed by HT showed a high diagnostic accuracy when compared against ADT (kappa 0.65-0.81; sensitivity 74%; specificity 96.7%; positive predictive value 22; negative predictive value 0.26). HTis a simple, quick, inexpensive and programmatically important method. However, being a subjective assessment, its reliability depends on the investigator being adequately trained and competent in making consistently accurate assessments. There is also a need to assess whether with training and supervision even the less literate mothers, traditional birth attendants and community health volunteers can accurately assess mild and moderate hypothermia before promoting HT for early identification of neonatal risk in community-based programs.

Original languageEnglish (US)
Pages (from-to)200-201
Number of pages2
JournalJournal of tropical pediatrics
Volume54
Issue number3
DOIs
StatePublished - Jun 2008
Externally publishedYes

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Infectious Diseases

Fingerprint

Dive into the research topics of 'Human touch vs. axillary digital thermometry for detection of neonatal hypothermia at community level'. Together they form a unique fingerprint.

Cite this