High-throughput screening of chemical exchange saturation transfer MR contrast agents

Research output: Contribution to journalArticle

Abstract

A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B0). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air-tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal-noise-ratio, field of view and gradient strength for imaging.

Original languageEnglish (US)
Pages (from-to)162-170
Number of pages9
JournalContrast Media and Molecular Imaging
Volume5
Issue number3
DOIs
StatePublished - May 2010

Fingerprint

Contrast Media
Plastics
Water
High-Throughput Screening Assays
Magnetic Fields
Liposomes
Glass
Noise
Air
Peptides

Keywords

  • B correction
  • CEST
  • High-throughput
  • MRI

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

@article{99c045c4ade947759f23902e73639551,
title = "High-throughput screening of chemical exchange saturation transfer MR contrast agents",
abstract = "A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B0). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air-tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal-noise-ratio, field of view and gradient strength for imaging.",
keywords = "B correction, CEST, High-throughput, MRI",
author = "Guanshu Liu and Gilad, {Assaf A.} and Bulte, {Jeff W} and {Van Zijl}, {Peter C} and Mcmahon, {Michael T}",
year = "2010",
month = "5",
doi = "10.1002/cmmi.383",
language = "English (US)",
volume = "5",
pages = "162--170",
journal = "Contrast Media and Molecular Imaging",
issn = "1555-4309",
publisher = "John Wiley and Sons Ltd",
number = "3",

}

TY - JOUR

T1 - High-throughput screening of chemical exchange saturation transfer MR contrast agents

AU - Liu, Guanshu

AU - Gilad, Assaf A.

AU - Bulte, Jeff W

AU - Van Zijl, Peter C

AU - Mcmahon, Michael T

PY - 2010/5

Y1 - 2010/5

N2 - A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B0). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air-tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal-noise-ratio, field of view and gradient strength for imaging.

AB - A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B0). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air-tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal-noise-ratio, field of view and gradient strength for imaging.

KW - B correction

KW - CEST

KW - High-throughput

KW - MRI

UR - http://www.scopus.com/inward/record.url?scp=77954567160&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954567160&partnerID=8YFLogxK

U2 - 10.1002/cmmi.383

DO - 10.1002/cmmi.383

M3 - Article

C2 - 20586030

AN - SCOPUS:77954567160

VL - 5

SP - 162

EP - 170

JO - Contrast Media and Molecular Imaging

JF - Contrast Media and Molecular Imaging

SN - 1555-4309

IS - 3

ER -