Four methods of measuring tidal volume during high-frequency oscillatory ventilation

David N. Hager, Mathew Fuld, David W. Kaczka, Henry E. Fessler, Roy G. Brower, Brett A. Simon

Research output: Contribution to journalArticlepeer-review

30 Scopus citations

Abstract

Objective: Assess the accuracy of four different methods of measuring tidal volume during simulated high-frequency oscillatory ventilation. Design: In vitro study. Setting: Research laboratory. Subjects: Three differential pressure pneumotachometers, a modified Pitot tube, an ultrasound flowmeter, and an adult hot wire anemometer. Interventions: Each device was placed in series with a Sensormedics 3100B high-frequency ventilator and an 8.0-mm endotracheal tube attached to a 48.9-L plethysmograph. Inspiratory/ expiratory ratio was fixed at 1:1 and mean airway pressure at 10 cm H2O. Tidal volumes were calculated at each combination of frequency (f: 3, 4, 6, 8, 10, 12 Hz) and pressure amplitude (ΔP: 30, 60, 90 cm H2O) by digital integration of the sampled flow signals from each device and compared with those calculated from pressure changes within the plethysmograph. The protocol was repeated after incorporation of frequency-specific calibrations to the flow-measuring algorithm of each device. The hot wire anemometer was further evaluated at FIO2 of 1.0, 37°C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. Measurements and Main Results: Tidal volumes were 36-305 mL. Bland-Altman analysis demonstrated that each device exhibited systematic bias before frequency-specific adjustment. After frequency-specific adjustment of the flow-measuring algorithm, the two most accurate and precise devices were the Hans Rudolph pneumotachometer, which exhibited a mean error of 0.2% (95% confidence interval, -3.0% to 3.4%), and the hot wire anemometer, which had a mean error of -1.1% (95% confidence interval, -5.5% to 3.3%). The hot wire anemometer remained accurate at FIO2 1.0, 37°C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. Conclusions: Tidal volume can be measured during high-frequency oscillatory ventilation using a variety of techniques. Frequency-specific calibration improves the accuracy and precision of tidal volume measurements. Hot wire anemometry exhibits stable performance characteristics across the range of temperature, humidity, FIO2, and inspiratory/expiratory ratios encountered clinically, has a small deadspace, is unaffected by mean airway pressure, and is therefore suitable for clinical applications.

Original languageEnglish (US)
Pages (from-to)751-757
Number of pages7
JournalCritical care medicine
Volume34
Issue number3
DOIs
StatePublished - Mar 2006

Keywords

  • Anemometer
  • Flowmeter
  • High-frequency ventilation
  • Mechanical ventilation
  • Pneumotachograph
  • Tidal volume

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

Fingerprint

Dive into the research topics of 'Four methods of measuring tidal volume during high-frequency oscillatory ventilation'. Together they form a unique fingerprint.

Cite this