OBJECTIVE Flow diversion has proven to be an efficacious means of treating cerebral aneurysms that are refractory to other therapeutic means. Patients with tandem aneurysms treated with flow diversion have been included in larger, previously reported series; however, there are no dedicated reports on using this technique during a single session to treat this unique subset of patients. Therefore, the authors analyzed the outcomes of patients who had undergone singlesession flow diversion for the treatment of tandem aneurysms. METHODS The authors conducted a retrospective review of flow diversion with the Pipeline embolization device (PED) for the treatment of tandem aneurysms in a single session at 2 participating medical centers: University of Utah, Salt Lake City, Utah, and Barrow Neurological Institute, Phoenix, Arizona. Patient demographic data, aneurysm characteristics, treatment strategy and results, complications, and follow-up data were collected from the medical record and analyzed. RESULTS Between January 2011 and December 2015, 17 patients (12 female, 5 male) with a total of 38 aneurysms (mean size 4.7 ± 2.7 mm, mean ± SD) were treated. Sixteen patients had aneurysms in the anterior circulation, and 1 patient had tandem aneurysms in the posterior circulation. Twelve patients underwent only placement of a PED, whereas 5 underwent adjunctive coil embolization of at least 1 aneurysm. One PED was used in each of 9 patients, and 2 PEDs were required in each of 8 patients. There were 2 intraprocedural complications; however, in both instances, the patients were asymptomatic at the last follow-up. The follow-up imaging studies were available for 15 patients at a mean of 7 months after treatment (216 days, range 0-540 days). The mean initial Raymond score after treatment was 2.7 ± 0.7, and the mean final score was 1.3 ± 0.7. CONCLUSIONS In this series, the use of flow diversion for the treatment of tandem cerebral aneurysms had an acceptable safety profile, indicating that it should be considered as an effective therapy for this complicated subset of patients. Further prospective studies must be performed before more definitive conclusions can be made.

Original languageEnglish (US)
Article numberE10
JournalNeurosurgical focus
Volume42
Issue number6
DOIs
StatePublished - Jun 1 2017
Externally publishedYes

Keywords

  • Endovascular
  • Flow diversion
  • Pipeline embolization device
  • Tandem aneurysms

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Flow diversion of tandem cerebral aneurysms: A multi-institutional retrospective study'. Together they form a unique fingerprint.

Cite this