Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer

Lin Su, Iulian Iordachita, Yin Zhang, Junghoon Lee, Sook Kien Ng, Juan Jackson, Ted Hooker, John Wong, Joseph M. Herman, H. Tutkun Sen, Peter Kazanzides, Muyinatu A. Lediju Bell, Chen Yang, Kai Ding

Research output: Contribution to journalArticle

Abstract

Purpose: Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. Methods and Materials: An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. Results: The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2 mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 ± 0.08 mm, 0.04 ± 0.1 mm, and 0.25 ± 0.09 mm in three directions. On dosimetry part, 100% of virtual simulation plans passed protocol criteria. Conclusions: Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.

Original languageEnglish (US)
Pages (from-to)84-96
Number of pages13
JournalJournal of Applied Clinical Medical Physics
Volume18
Issue number4
DOIs
StatePublished - Jul 1 2017

Fingerprint

Radiotherapy
Feasibility Studies
breathing
Pancreatic Neoplasms
radiation therapy
Ultrasonography
Respiration
Ultrasonics
cancer
pancreas
Imaging techniques
Volunteers
Monitoring
Pancreas
active control
planning
probes
Healthy Volunteers
Dosimetry
Radiation Monitoring

Keywords

  • Intrafraction
  • Pancreas
  • SBRT
  • Ultrasound

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Cite this

Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer. / Su, Lin; Iordachita, Iulian; Zhang, Yin; Lee, Junghoon; Ng, Sook Kien; Jackson, Juan; Hooker, Ted; Wong, John; Herman, Joseph M.; Tutkun Sen, H.; Kazanzides, Peter; Lediju Bell, Muyinatu A.; Yang, Chen; Ding, Kai.

In: Journal of Applied Clinical Medical Physics, Vol. 18, No. 4, 01.07.2017, p. 84-96.

Research output: Contribution to journalArticle

Su, L, Iordachita, I, Zhang, Y, Lee, J, Ng, SK, Jackson, J, Hooker, T, Wong, J, Herman, JM, Tutkun Sen, H, Kazanzides, P, Lediju Bell, MA, Yang, C & Ding, K 2017, 'Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer', Journal of Applied Clinical Medical Physics, vol. 18, no. 4, pp. 84-96. https://doi.org/10.1002/acm2.12100
Su, Lin ; Iordachita, Iulian ; Zhang, Yin ; Lee, Junghoon ; Ng, Sook Kien ; Jackson, Juan ; Hooker, Ted ; Wong, John ; Herman, Joseph M. ; Tutkun Sen, H. ; Kazanzides, Peter ; Lediju Bell, Muyinatu A. ; Yang, Chen ; Ding, Kai. / Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer. In: Journal of Applied Clinical Medical Physics. 2017 ; Vol. 18, No. 4. pp. 84-96.
@article{c5a1fbfc592a43d1bcabb5be36258f8d,
title = "Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer",
abstract = "Purpose: Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. Methods and Materials: An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. Results: The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2 mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 ± 0.08 mm, 0.04 ± 0.1 mm, and 0.25 ± 0.09 mm in three directions. On dosimetry part, 100{\%} of virtual simulation plans passed protocol criteria. Conclusions: Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.",
keywords = "Intrafraction, Pancreas, SBRT, Ultrasound",
author = "Lin Su and Iulian Iordachita and Yin Zhang and Junghoon Lee and Ng, {Sook Kien} and Juan Jackson and Ted Hooker and John Wong and Herman, {Joseph M.} and {Tutkun Sen}, H. and Peter Kazanzides and {Lediju Bell}, {Muyinatu A.} and Chen Yang and Kai Ding",
year = "2017",
month = "7",
day = "1",
doi = "10.1002/acm2.12100",
language = "English (US)",
volume = "18",
pages = "84--96",
journal = "Journal of Applied Clinical Medical Physics",
issn = "1526-9914",
publisher = "American Institute of Physics Publising LLC",
number = "4",

}

TY - JOUR

T1 - Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer

AU - Su, Lin

AU - Iordachita, Iulian

AU - Zhang, Yin

AU - Lee, Junghoon

AU - Ng, Sook Kien

AU - Jackson, Juan

AU - Hooker, Ted

AU - Wong, John

AU - Herman, Joseph M.

AU - Tutkun Sen, H.

AU - Kazanzides, Peter

AU - Lediju Bell, Muyinatu A.

AU - Yang, Chen

AU - Ding, Kai

PY - 2017/7/1

Y1 - 2017/7/1

N2 - Purpose: Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. Methods and Materials: An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. Results: The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2 mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 ± 0.08 mm, 0.04 ± 0.1 mm, and 0.25 ± 0.09 mm in three directions. On dosimetry part, 100% of virtual simulation plans passed protocol criteria. Conclusions: Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.

AB - Purpose: Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. Methods and Materials: An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. Results: The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2 mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 ± 0.08 mm, 0.04 ± 0.1 mm, and 0.25 ± 0.09 mm in three directions. On dosimetry part, 100% of virtual simulation plans passed protocol criteria. Conclusions: Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.

KW - Intrafraction

KW - Pancreas

KW - SBRT

KW - Ultrasound

UR - http://www.scopus.com/inward/record.url?scp=85020101815&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85020101815&partnerID=8YFLogxK

U2 - 10.1002/acm2.12100

DO - 10.1002/acm2.12100

M3 - Article

VL - 18

SP - 84

EP - 96

JO - Journal of Applied Clinical Medical Physics

JF - Journal of Applied Clinical Medical Physics

SN - 1526-9914

IS - 4

ER -