Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm

Matthias Fippel, Wolfram Laub, Bernd Huber, Fridtjof Nüsslin

Research output: Contribution to journalArticle

Abstract

An experimental verification of the recently developed XVMC code, a fast Monte Carlo algorithm to calculate dose distributions of photon beams in treatment planning, is presented. The treatment head is modelled by a point source with energy distribution (primary photons) and an additional head scatter contribution. Utility software is presented, allowing the determination of the parameters for this model using a single measured depth dose curve in water. The simple beam model is considered to be a starting point for more complex models being planned for future versions of the code. This paper is mainly focused on the influence of the different techniques on variance reduction and material property determination for dose distributions. It is demonstrated that XVMC and the simple beam model reproduce measured (by a diamond detector) relative dose distributions with an accuracy of better than ±2% in various homogeneous and inhomogeneous phantoms. Furthermore, relative dose distributions in solid state phantoms have been measured by film. Also for these cases, measured and calculated dose distributions agree within experimental uncertainty. The short calculation time (depending on voxel resolution, statistical accuracy, field size and energy, a span of 1 min to 1 h using a present-day personal computer) and an interface to a commercial planning system will allow the implementation of the code for routine treatment planning of clinical electron and photon beams.

Original languageEnglish (US)
Pages (from-to)3039-3054
Number of pages16
JournalPhysics in Medicine and Biology
Volume44
Issue number12
DOIs
StatePublished - Dec 1 1999
Externally publishedYes

Fingerprint

photon beams
Photons
Dosimetry
dosage
Head
Planning
planning
Diamond
Microcomputers
Uncertainty
Software
Personal computers
Electrons
Diamonds
Materials properties
Water
personal computers
Detectors
point sources
energy distribution

ASJC Scopus subject areas

  • Biomedical Engineering
  • Physics and Astronomy (miscellaneous)
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm. / Fippel, Matthias; Laub, Wolfram; Huber, Bernd; Nüsslin, Fridtjof.

In: Physics in Medicine and Biology, Vol. 44, No. 12, 01.12.1999, p. 3039-3054.

Research output: Contribution to journalArticle

Fippel, Matthias ; Laub, Wolfram ; Huber, Bernd ; Nüsslin, Fridtjof. / Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm. In: Physics in Medicine and Biology. 1999 ; Vol. 44, No. 12. pp. 3039-3054.
@article{90d95674e5e04e7a8e36f420f7e1d114,
title = "Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm",
abstract = "An experimental verification of the recently developed XVMC code, a fast Monte Carlo algorithm to calculate dose distributions of photon beams in treatment planning, is presented. The treatment head is modelled by a point source with energy distribution (primary photons) and an additional head scatter contribution. Utility software is presented, allowing the determination of the parameters for this model using a single measured depth dose curve in water. The simple beam model is considered to be a starting point for more complex models being planned for future versions of the code. This paper is mainly focused on the influence of the different techniques on variance reduction and material property determination for dose distributions. It is demonstrated that XVMC and the simple beam model reproduce measured (by a diamond detector) relative dose distributions with an accuracy of better than ±2{\%} in various homogeneous and inhomogeneous phantoms. Furthermore, relative dose distributions in solid state phantoms have been measured by film. Also for these cases, measured and calculated dose distributions agree within experimental uncertainty. The short calculation time (depending on voxel resolution, statistical accuracy, field size and energy, a span of 1 min to 1 h using a present-day personal computer) and an interface to a commercial planning system will allow the implementation of the code for routine treatment planning of clinical electron and photon beams.",
author = "Matthias Fippel and Wolfram Laub and Bernd Huber and Fridtjof N{\"u}sslin",
year = "1999",
month = "12",
day = "1",
doi = "10.1088/0031-9155/44/12/313",
language = "English (US)",
volume = "44",
pages = "3039--3054",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "12",

}

TY - JOUR

T1 - Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm

AU - Fippel, Matthias

AU - Laub, Wolfram

AU - Huber, Bernd

AU - Nüsslin, Fridtjof

PY - 1999/12/1

Y1 - 1999/12/1

N2 - An experimental verification of the recently developed XVMC code, a fast Monte Carlo algorithm to calculate dose distributions of photon beams in treatment planning, is presented. The treatment head is modelled by a point source with energy distribution (primary photons) and an additional head scatter contribution. Utility software is presented, allowing the determination of the parameters for this model using a single measured depth dose curve in water. The simple beam model is considered to be a starting point for more complex models being planned for future versions of the code. This paper is mainly focused on the influence of the different techniques on variance reduction and material property determination for dose distributions. It is demonstrated that XVMC and the simple beam model reproduce measured (by a diamond detector) relative dose distributions with an accuracy of better than ±2% in various homogeneous and inhomogeneous phantoms. Furthermore, relative dose distributions in solid state phantoms have been measured by film. Also for these cases, measured and calculated dose distributions agree within experimental uncertainty. The short calculation time (depending on voxel resolution, statistical accuracy, field size and energy, a span of 1 min to 1 h using a present-day personal computer) and an interface to a commercial planning system will allow the implementation of the code for routine treatment planning of clinical electron and photon beams.

AB - An experimental verification of the recently developed XVMC code, a fast Monte Carlo algorithm to calculate dose distributions of photon beams in treatment planning, is presented. The treatment head is modelled by a point source with energy distribution (primary photons) and an additional head scatter contribution. Utility software is presented, allowing the determination of the parameters for this model using a single measured depth dose curve in water. The simple beam model is considered to be a starting point for more complex models being planned for future versions of the code. This paper is mainly focused on the influence of the different techniques on variance reduction and material property determination for dose distributions. It is demonstrated that XVMC and the simple beam model reproduce measured (by a diamond detector) relative dose distributions with an accuracy of better than ±2% in various homogeneous and inhomogeneous phantoms. Furthermore, relative dose distributions in solid state phantoms have been measured by film. Also for these cases, measured and calculated dose distributions agree within experimental uncertainty. The short calculation time (depending on voxel resolution, statistical accuracy, field size and energy, a span of 1 min to 1 h using a present-day personal computer) and an interface to a commercial planning system will allow the implementation of the code for routine treatment planning of clinical electron and photon beams.

UR - http://www.scopus.com/inward/record.url?scp=0032761985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032761985&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/44/12/313

DO - 10.1088/0031-9155/44/12/313

M3 - Article

C2 - 10616153

AN - SCOPUS:0032761985

VL - 44

SP - 3039

EP - 3054

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 12

ER -