Numerical studies were performed to evaluate and compare four different algorithms for tomographically reconstructing pollutant concentrations in indoor air measured with an optical remote sensing system. With a remote sensing/computed tomography system, two-dimensional maps of air concentrations can be created for an entire room with good spatial and temporal resolution. The success of such a system for characterizing the flow of contaminants in air, exposure assessment, and leak detection depends on the choice of tomographic reconstruction algorithm. A systematic method was developed to evaluate the performance of four algorithms: ART, ART3, SIRT, and SART. One hundred and twenty test maps were reconstructed by each algorithm under ideal and nonideal sampling conditions, and image quality was evaluated using four criteria. The nonideal sampling conditions included simulation of measurement noise and reduction in the number density of rays. Performance of the algorithms was found to be intimately related to the number of peaks in the test maps. The importance of using multiple measures of image quality was underscored by the fact that for some sampling conditions simulated, performance of the algorithms was judged differently depending on the evaluation criteria. Results indicated that using numerical studies is successful for evaluating such algorithms.

Original languageEnglish (US)
Pages (from-to)403-417
Number of pages15
JournalAmerican Industrial Hygiene Association Journal
Volume55
Issue number5
DOIs
StatePublished - 1994
Externally publishedYes

Fingerprint

Air
Noise
Tomography

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Cite this

@article{df288499bfff4c36908d1545d591c8be,
title = "Evaluation of Algorithms for Tomographic Reconstruction of Chemical Concentrations in Indoor Air",
abstract = "Numerical studies were performed to evaluate and compare four different algorithms for tomographically reconstructing pollutant concentrations in indoor air measured with an optical remote sensing system. With a remote sensing/computed tomography system, two-dimensional maps of air concentrations can be created for an entire room with good spatial and temporal resolution. The success of such a system for characterizing the flow of contaminants in air, exposure assessment, and leak detection depends on the choice of tomographic reconstruction algorithm. A systematic method was developed to evaluate the performance of four algorithms: ART, ART3, SIRT, and SART. One hundred and twenty test maps were reconstructed by each algorithm under ideal and nonideal sampling conditions, and image quality was evaluated using four criteria. The nonideal sampling conditions included simulation of measurement noise and reduction in the number density of rays. Performance of the algorithms was found to be intimately related to the number of peaks in the test maps. The importance of using multiple measures of image quality was underscored by the fact that for some sampling conditions simulated, performance of the algorithms was judged differently depending on the evaluation criteria. Results indicated that using numerical studies is successful for evaluating such algorithms.",
author = "L. Todd and Gurumurthy Ramachandran",
year = "1994",
doi = "10.1080/15428119491018844",
language = "English (US)",
volume = "55",
pages = "403--417",
journal = "Journal of Occupational and Environmental Hygiene",
issn = "1545-9624",
publisher = "Taylor and Francis Ltd.",
number = "5",

}

TY - JOUR

T1 - Evaluation of Algorithms for Tomographic Reconstruction of Chemical Concentrations in Indoor Air

AU - Todd, L.

AU - Ramachandran, Gurumurthy

PY - 1994

Y1 - 1994

N2 - Numerical studies were performed to evaluate and compare four different algorithms for tomographically reconstructing pollutant concentrations in indoor air measured with an optical remote sensing system. With a remote sensing/computed tomography system, two-dimensional maps of air concentrations can be created for an entire room with good spatial and temporal resolution. The success of such a system for characterizing the flow of contaminants in air, exposure assessment, and leak detection depends on the choice of tomographic reconstruction algorithm. A systematic method was developed to evaluate the performance of four algorithms: ART, ART3, SIRT, and SART. One hundred and twenty test maps were reconstructed by each algorithm under ideal and nonideal sampling conditions, and image quality was evaluated using four criteria. The nonideal sampling conditions included simulation of measurement noise and reduction in the number density of rays. Performance of the algorithms was found to be intimately related to the number of peaks in the test maps. The importance of using multiple measures of image quality was underscored by the fact that for some sampling conditions simulated, performance of the algorithms was judged differently depending on the evaluation criteria. Results indicated that using numerical studies is successful for evaluating such algorithms.

AB - Numerical studies were performed to evaluate and compare four different algorithms for tomographically reconstructing pollutant concentrations in indoor air measured with an optical remote sensing system. With a remote sensing/computed tomography system, two-dimensional maps of air concentrations can be created for an entire room with good spatial and temporal resolution. The success of such a system for characterizing the flow of contaminants in air, exposure assessment, and leak detection depends on the choice of tomographic reconstruction algorithm. A systematic method was developed to evaluate the performance of four algorithms: ART, ART3, SIRT, and SART. One hundred and twenty test maps were reconstructed by each algorithm under ideal and nonideal sampling conditions, and image quality was evaluated using four criteria. The nonideal sampling conditions included simulation of measurement noise and reduction in the number density of rays. Performance of the algorithms was found to be intimately related to the number of peaks in the test maps. The importance of using multiple measures of image quality was underscored by the fact that for some sampling conditions simulated, performance of the algorithms was judged differently depending on the evaluation criteria. Results indicated that using numerical studies is successful for evaluating such algorithms.

UR - http://www.scopus.com/inward/record.url?scp=0028328774&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028328774&partnerID=8YFLogxK

U2 - 10.1080/15428119491018844

DO - 10.1080/15428119491018844

M3 - Article

VL - 55

SP - 403

EP - 417

JO - Journal of Occupational and Environmental Hygiene

JF - Journal of Occupational and Environmental Hygiene

SN - 1545-9624

IS - 5

ER -