Estimation of geometrical parameters for fan beam tomography

G. T. Gullberg, Benjamin Tsui, C. R. Crawford, E. R. Edgerton

Research output: Contribution to journalArticle

Abstract

Tomographic image quality depends on precisely determining the geometric parameters that reference the detector system to the transaxial imaging coordinate system. In addition to the projection of the centre of rotation onto the detector, fan beam geometry requires two other parameters that include the focal length and the projection of the focal point onto the detector. Heretofore no method has been developed for estimating the geometrical parameters of a fan beam detector system. A method is presented for estimating these parameters from centroids of the measured projections of a point source using the non-linear estimation algorithm due to Marquardt. The technique is applied to single photon emission computed tomography (SPECT) data from a rotating gamma camera using a fan beam collimator. The parameters can be determined very quickly in a clinical environment. The corresponding reconstructed images do not show image artefacts or loss of resolution characteristic of inaccurately determined geometric parameters.

Original languageEnglish (US)
Article number005
Pages (from-to)1581-1594
Number of pages14
JournalPhysics in Medicine and Biology
Volume32
Issue number12
DOIs
StatePublished - 1987
Externally publishedYes

Fingerprint

fans
Fans
Tomography
tomography
Detectors
Gamma Cameras
Single-Photon Emission-Computed Tomography
Artifacts
projection
detectors
Single photon emission computed tomography
estimating
Image quality
Cameras
collimators
Imaging techniques
centroids
point sources
Geometry
artifacts

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging
  • Physics and Astronomy (miscellaneous)
  • Biomedical Engineering

Cite this

Estimation of geometrical parameters for fan beam tomography. / Gullberg, G. T.; Tsui, Benjamin; Crawford, C. R.; Edgerton, E. R.

In: Physics in Medicine and Biology, Vol. 32, No. 12, 005, 1987, p. 1581-1594.

Research output: Contribution to journalArticle

Gullberg, G. T. ; Tsui, Benjamin ; Crawford, C. R. ; Edgerton, E. R. / Estimation of geometrical parameters for fan beam tomography. In: Physics in Medicine and Biology. 1987 ; Vol. 32, No. 12. pp. 1581-1594.
@article{d43fb1a428374602a93e4de266074fda,
title = "Estimation of geometrical parameters for fan beam tomography",
abstract = "Tomographic image quality depends on precisely determining the geometric parameters that reference the detector system to the transaxial imaging coordinate system. In addition to the projection of the centre of rotation onto the detector, fan beam geometry requires two other parameters that include the focal length and the projection of the focal point onto the detector. Heretofore no method has been developed for estimating the geometrical parameters of a fan beam detector system. A method is presented for estimating these parameters from centroids of the measured projections of a point source using the non-linear estimation algorithm due to Marquardt. The technique is applied to single photon emission computed tomography (SPECT) data from a rotating gamma camera using a fan beam collimator. The parameters can be determined very quickly in a clinical environment. The corresponding reconstructed images do not show image artefacts or loss of resolution characteristic of inaccurately determined geometric parameters.",
author = "Gullberg, {G. T.} and Benjamin Tsui and Crawford, {C. R.} and Edgerton, {E. R.}",
year = "1987",
doi = "10.1088/0031-9155/32/12/005",
language = "English (US)",
volume = "32",
pages = "1581--1594",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "12",

}

TY - JOUR

T1 - Estimation of geometrical parameters for fan beam tomography

AU - Gullberg, G. T.

AU - Tsui, Benjamin

AU - Crawford, C. R.

AU - Edgerton, E. R.

PY - 1987

Y1 - 1987

N2 - Tomographic image quality depends on precisely determining the geometric parameters that reference the detector system to the transaxial imaging coordinate system. In addition to the projection of the centre of rotation onto the detector, fan beam geometry requires two other parameters that include the focal length and the projection of the focal point onto the detector. Heretofore no method has been developed for estimating the geometrical parameters of a fan beam detector system. A method is presented for estimating these parameters from centroids of the measured projections of a point source using the non-linear estimation algorithm due to Marquardt. The technique is applied to single photon emission computed tomography (SPECT) data from a rotating gamma camera using a fan beam collimator. The parameters can be determined very quickly in a clinical environment. The corresponding reconstructed images do not show image artefacts or loss of resolution characteristic of inaccurately determined geometric parameters.

AB - Tomographic image quality depends on precisely determining the geometric parameters that reference the detector system to the transaxial imaging coordinate system. In addition to the projection of the centre of rotation onto the detector, fan beam geometry requires two other parameters that include the focal length and the projection of the focal point onto the detector. Heretofore no method has been developed for estimating the geometrical parameters of a fan beam detector system. A method is presented for estimating these parameters from centroids of the measured projections of a point source using the non-linear estimation algorithm due to Marquardt. The technique is applied to single photon emission computed tomography (SPECT) data from a rotating gamma camera using a fan beam collimator. The parameters can be determined very quickly in a clinical environment. The corresponding reconstructed images do not show image artefacts or loss of resolution characteristic of inaccurately determined geometric parameters.

UR - http://www.scopus.com/inward/record.url?scp=0023519549&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023519549&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/32/12/005

DO - 10.1088/0031-9155/32/12/005

M3 - Article

AN - SCOPUS:0023519549

VL - 32

SP - 1581

EP - 1594

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 12

M1 - 005

ER -