Estimating amounts of iron oxide from gradient echo images

W. Thomas Dixon, Daniel J. Blezek, Lisa A. Lowery, Dan E. Meyer, Amit M. Kulkarni, Brian C. Bales, Danielle L. Petko, Thomas K. Foo

Research output: Contribution to journalArticle

Abstract

Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was ∼110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 μL, 3-μg iron injection produced signal void volumes of 80 and 210 μL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 ± 1 and 10 ± 2 μg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos2θ - 1)/|r|3 spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 ± 0.26 μg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-μg injection indicated 0.5, 1.2, and 1.2 μg.

Original languageEnglish (US)
Pages (from-to)1132-1136
Number of pages5
JournalMagnetic Resonance in Medicine
Volume61
Issue number5
DOIs
StatePublished - May 2009
Externally publishedYes

Fingerprint

Iron
Injections
Dromaiidae
Silanes
Hydrodynamics
ferric oxide
Leg

Keywords

  • Iron oxide
  • Quantitative imaging
  • SPIO
  • Superparamagentic

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Dixon, W. T., Blezek, D. J., Lowery, L. A., Meyer, D. E., Kulkarni, A. M., Bales, B. C., ... Foo, T. K. (2009). Estimating amounts of iron oxide from gradient echo images. Magnetic Resonance in Medicine, 61(5), 1132-1136. https://doi.org/10.1002/mrm.21930

Estimating amounts of iron oxide from gradient echo images. / Dixon, W. Thomas; Blezek, Daniel J.; Lowery, Lisa A.; Meyer, Dan E.; Kulkarni, Amit M.; Bales, Brian C.; Petko, Danielle L.; Foo, Thomas K.

In: Magnetic Resonance in Medicine, Vol. 61, No. 5, 05.2009, p. 1132-1136.

Research output: Contribution to journalArticle

Dixon, WT, Blezek, DJ, Lowery, LA, Meyer, DE, Kulkarni, AM, Bales, BC, Petko, DL & Foo, TK 2009, 'Estimating amounts of iron oxide from gradient echo images', Magnetic Resonance in Medicine, vol. 61, no. 5, pp. 1132-1136. https://doi.org/10.1002/mrm.21930
Dixon WT, Blezek DJ, Lowery LA, Meyer DE, Kulkarni AM, Bales BC et al. Estimating amounts of iron oxide from gradient echo images. Magnetic Resonance in Medicine. 2009 May;61(5):1132-1136. https://doi.org/10.1002/mrm.21930
Dixon, W. Thomas ; Blezek, Daniel J. ; Lowery, Lisa A. ; Meyer, Dan E. ; Kulkarni, Amit M. ; Bales, Brian C. ; Petko, Danielle L. ; Foo, Thomas K. / Estimating amounts of iron oxide from gradient echo images. In: Magnetic Resonance in Medicine. 2009 ; Vol. 61, No. 5. pp. 1132-1136.
@article{05b5ecc3a5f145039684defdd708ebf7,
title = "Estimating amounts of iron oxide from gradient echo images",
abstract = "Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was ∼110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 μL, 3-μg iron injection produced signal void volumes of 80 and 210 μL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 ± 1 and 10 ± 2 μg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos2θ - 1)/|r|3 spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 ± 0.26 μg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-μg injection indicated 0.5, 1.2, and 1.2 μg.",
keywords = "Iron oxide, Quantitative imaging, SPIO, Superparamagentic",
author = "Dixon, {W. Thomas} and Blezek, {Daniel J.} and Lowery, {Lisa A.} and Meyer, {Dan E.} and Kulkarni, {Amit M.} and Bales, {Brian C.} and Petko, {Danielle L.} and Foo, {Thomas K.}",
year = "2009",
month = "5",
doi = "10.1002/mrm.21930",
language = "English (US)",
volume = "61",
pages = "1132--1136",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - Estimating amounts of iron oxide from gradient echo images

AU - Dixon, W. Thomas

AU - Blezek, Daniel J.

AU - Lowery, Lisa A.

AU - Meyer, Dan E.

AU - Kulkarni, Amit M.

AU - Bales, Brian C.

AU - Petko, Danielle L.

AU - Foo, Thomas K.

PY - 2009/5

Y1 - 2009/5

N2 - Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was ∼110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 μL, 3-μg iron injection produced signal void volumes of 80 and 210 μL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 ± 1 and 10 ± 2 μg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos2θ - 1)/|r|3 spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 ± 0.26 μg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-μg injection indicated 0.5, 1.2, and 1.2 μg.

AB - Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was ∼110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 μL, 3-μg iron injection produced signal void volumes of 80 and 210 μL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 ± 1 and 10 ± 2 μg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos2θ - 1)/|r|3 spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 ± 0.26 μg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-μg injection indicated 0.5, 1.2, and 1.2 μg.

KW - Iron oxide

KW - Quantitative imaging

KW - SPIO

KW - Superparamagentic

UR - http://www.scopus.com/inward/record.url?scp=66149120306&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=66149120306&partnerID=8YFLogxK

U2 - 10.1002/mrm.21930

DO - 10.1002/mrm.21930

M3 - Article

VL - 61

SP - 1132

EP - 1136

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -