TY - JOUR
T1 - Enhanced 3D PET OSEM reconstruction using inter-update metz filtering
AU - Jacobson, M.
AU - Levkovitz, R.
AU - Ben-Tal, A.
AU - Thielemans, K.
AU - Spinks, T.
AU - Belluzzo, D.
AU - Pagani, E.
AU - Bettinardi, V.
AU - Gilardi, M. C.
AU - Zverovich, A.
AU - Mitra, G.
PY - 2000
Y1 - 2000
N2 - We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image - ordinarily used to update image estimates in plain OSEM - is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software.
AB - We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image - ordinarily used to update image estimates in plain OSEM - is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software.
UR - http://www.scopus.com/inward/record.url?scp=0033867061&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033867061&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/45/8/325
DO - 10.1088/0031-9155/45/8/325
M3 - Article
C2 - 10958204
AN - SCOPUS:0033867061
SN - 0031-9155
VL - 45
SP - 2417
EP - 2439
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 8
ER -