Eliminating patellofemoral complications in total knee arthroplasty: Clinical and radiographic results of 121 consecutive cases using the Duracon system

Michael A. Mont, Taek Rim Yoon, Kenneth A. Krackow, David S. Hungerford

Research output: Contribution to journalArticle

Abstract

This study reports the minimum 5-year follow-up of our experience with the Duracon Total Knee Arthroplasty System. A total of 121 consecutive total knee replacements using the Duracon system (Howmedica, Rutherford, NJ) were performed in 104 patients. Three patients died before the 5-year follow-up and were excluded from the final evaluation. The remaining 118 knees (101 patients) were assessed at a mean follow-up of 65 months (range, 60-80 months). The knee diagnoses were osteoarthritis in 97 patients, rheumatoid arthritis in 2 patients, osteonecrosis in 1 patient, and pigmented villonodular synovitis in 1 patient. The mean age was 70 years (range, 28-85 years). There were no reoperations for aseptic loosening, and there have been no reoperations for patellofemoral problems. At final follow-up evaluation, 112 knees (96%) had good or excellent results, and 6 knees (4%) had poor clinical results or went on to revision. For the surviving knees, the preoperative Knee Society objective score improved from a mean of 52 points (range, 20-72 points) to a final follow-up mean of 94 points (range, 66-100 points). Five knees needed reoperations: 2 knees in 1 patient because of acute hematogenous infection at 12 months, 1 knee because of a supracondylar femur fracture, 1 because of a patellar tendon rupture, and 1 to increase polyethylene thickness because of instability. The lack of aseptic loosening at the minimum 5-year follow-up compares favorably with any cemented or cementless series of knee replacement. The almost complete absence of patellofemoral complications in this series also indicates that the design changes, with particular attention to the trochlea design and patellofemoral contact throughout full flexion, have achieved their intended purpose. The results are encouraging at midterm, awaiting true long-term (15-20 years) follow-up.

Original languageEnglish (US)
Pages (from-to)446-455
Number of pages10
JournalJournal of Arthroplasty
Volume14
Issue number4
DOIs
StatePublished - Jun 1999

Fingerprint

Knee Replacement Arthroplasties
Knee
Reoperation
Pigmented Villonodular Synovitis
Patellar Ligament
Osteonecrosis
Polyethylene
Osteoarthritis
Femur
Rupture
Rheumatoid Arthritis

Keywords

  • Patellofemoral joint
  • Total knee arthroplasty
  • Trochlear groove

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Eliminating patellofemoral complications in total knee arthroplasty : Clinical and radiographic results of 121 consecutive cases using the Duracon system. / Mont, Michael A.; Yoon, Taek Rim; Krackow, Kenneth A.; Hungerford, David S.

In: Journal of Arthroplasty, Vol. 14, No. 4, 06.1999, p. 446-455.

Research output: Contribution to journalArticle

Mont, Michael A. ; Yoon, Taek Rim ; Krackow, Kenneth A. ; Hungerford, David S. / Eliminating patellofemoral complications in total knee arthroplasty : Clinical and radiographic results of 121 consecutive cases using the Duracon system. In: Journal of Arthroplasty. 1999 ; Vol. 14, No. 4. pp. 446-455.
@article{bdadc56f93474659a5565092daa843bc,
title = "Eliminating patellofemoral complications in total knee arthroplasty: Clinical and radiographic results of 121 consecutive cases using the Duracon system",
abstract = "This study reports the minimum 5-year follow-up of our experience with the Duracon Total Knee Arthroplasty System. A total of 121 consecutive total knee replacements using the Duracon system (Howmedica, Rutherford, NJ) were performed in 104 patients. Three patients died before the 5-year follow-up and were excluded from the final evaluation. The remaining 118 knees (101 patients) were assessed at a mean follow-up of 65 months (range, 60-80 months). The knee diagnoses were osteoarthritis in 97 patients, rheumatoid arthritis in 2 patients, osteonecrosis in 1 patient, and pigmented villonodular synovitis in 1 patient. The mean age was 70 years (range, 28-85 years). There were no reoperations for aseptic loosening, and there have been no reoperations for patellofemoral problems. At final follow-up evaluation, 112 knees (96{\%}) had good or excellent results, and 6 knees (4{\%}) had poor clinical results or went on to revision. For the surviving knees, the preoperative Knee Society objective score improved from a mean of 52 points (range, 20-72 points) to a final follow-up mean of 94 points (range, 66-100 points). Five knees needed reoperations: 2 knees in 1 patient because of acute hematogenous infection at 12 months, 1 knee because of a supracondylar femur fracture, 1 because of a patellar tendon rupture, and 1 to increase polyethylene thickness because of instability. The lack of aseptic loosening at the minimum 5-year follow-up compares favorably with any cemented or cementless series of knee replacement. The almost complete absence of patellofemoral complications in this series also indicates that the design changes, with particular attention to the trochlea design and patellofemoral contact throughout full flexion, have achieved their intended purpose. The results are encouraging at midterm, awaiting true long-term (15-20 years) follow-up.",
keywords = "Patellofemoral joint, Total knee arthroplasty, Trochlear groove",
author = "Mont, {Michael A.} and Yoon, {Taek Rim} and Krackow, {Kenneth A.} and Hungerford, {David S.}",
year = "1999",
month = "6",
doi = "10.1016/S0883-5403(99)90100-6",
language = "English (US)",
volume = "14",
pages = "446--455",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "4",

}

TY - JOUR

T1 - Eliminating patellofemoral complications in total knee arthroplasty

T2 - Clinical and radiographic results of 121 consecutive cases using the Duracon system

AU - Mont, Michael A.

AU - Yoon, Taek Rim

AU - Krackow, Kenneth A.

AU - Hungerford, David S.

PY - 1999/6

Y1 - 1999/6

N2 - This study reports the minimum 5-year follow-up of our experience with the Duracon Total Knee Arthroplasty System. A total of 121 consecutive total knee replacements using the Duracon system (Howmedica, Rutherford, NJ) were performed in 104 patients. Three patients died before the 5-year follow-up and were excluded from the final evaluation. The remaining 118 knees (101 patients) were assessed at a mean follow-up of 65 months (range, 60-80 months). The knee diagnoses were osteoarthritis in 97 patients, rheumatoid arthritis in 2 patients, osteonecrosis in 1 patient, and pigmented villonodular synovitis in 1 patient. The mean age was 70 years (range, 28-85 years). There were no reoperations for aseptic loosening, and there have been no reoperations for patellofemoral problems. At final follow-up evaluation, 112 knees (96%) had good or excellent results, and 6 knees (4%) had poor clinical results or went on to revision. For the surviving knees, the preoperative Knee Society objective score improved from a mean of 52 points (range, 20-72 points) to a final follow-up mean of 94 points (range, 66-100 points). Five knees needed reoperations: 2 knees in 1 patient because of acute hematogenous infection at 12 months, 1 knee because of a supracondylar femur fracture, 1 because of a patellar tendon rupture, and 1 to increase polyethylene thickness because of instability. The lack of aseptic loosening at the minimum 5-year follow-up compares favorably with any cemented or cementless series of knee replacement. The almost complete absence of patellofemoral complications in this series also indicates that the design changes, with particular attention to the trochlea design and patellofemoral contact throughout full flexion, have achieved their intended purpose. The results are encouraging at midterm, awaiting true long-term (15-20 years) follow-up.

AB - This study reports the minimum 5-year follow-up of our experience with the Duracon Total Knee Arthroplasty System. A total of 121 consecutive total knee replacements using the Duracon system (Howmedica, Rutherford, NJ) were performed in 104 patients. Three patients died before the 5-year follow-up and were excluded from the final evaluation. The remaining 118 knees (101 patients) were assessed at a mean follow-up of 65 months (range, 60-80 months). The knee diagnoses were osteoarthritis in 97 patients, rheumatoid arthritis in 2 patients, osteonecrosis in 1 patient, and pigmented villonodular synovitis in 1 patient. The mean age was 70 years (range, 28-85 years). There were no reoperations for aseptic loosening, and there have been no reoperations for patellofemoral problems. At final follow-up evaluation, 112 knees (96%) had good or excellent results, and 6 knees (4%) had poor clinical results or went on to revision. For the surviving knees, the preoperative Knee Society objective score improved from a mean of 52 points (range, 20-72 points) to a final follow-up mean of 94 points (range, 66-100 points). Five knees needed reoperations: 2 knees in 1 patient because of acute hematogenous infection at 12 months, 1 knee because of a supracondylar femur fracture, 1 because of a patellar tendon rupture, and 1 to increase polyethylene thickness because of instability. The lack of aseptic loosening at the minimum 5-year follow-up compares favorably with any cemented or cementless series of knee replacement. The almost complete absence of patellofemoral complications in this series also indicates that the design changes, with particular attention to the trochlea design and patellofemoral contact throughout full flexion, have achieved their intended purpose. The results are encouraging at midterm, awaiting true long-term (15-20 years) follow-up.

KW - Patellofemoral joint

KW - Total knee arthroplasty

KW - Trochlear groove

UR - http://www.scopus.com/inward/record.url?scp=0032777569&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032777569&partnerID=8YFLogxK

U2 - 10.1016/S0883-5403(99)90100-6

DO - 10.1016/S0883-5403(99)90100-6

M3 - Article

C2 - 10428225

AN - SCOPUS:0032777569

VL - 14

SP - 446

EP - 455

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 4

ER -