Effect of RR interval variation on image quality in gated, two-dimensional, fourier MR imaging

Walter J. Rogers, Edward Shapiro

Research output: Contribution to journalArticle

Abstract

The effect of uneven repetition time (TR) intervals on artifact production during gated two-dimensional Fourier magnetic resonance image acquisition was investigated and a means of compensation presented. In standard spin-echo imaging, incomplete longitudinal recovery combines with normal respiratory heart rate variations to modulate signal intensity and create image copies and smearing along the phase direction. Modulation amplitude, frequency, and pattern, as well as machine parameters including echo time, TR, field of view, and image matrix size, have been found to have a substantial impact on artifact position and intensity. In a group of 10 healthy volunteers, respiratory-induced heart rate modulation produced an average of 17.2% ± 4.9 variation in the raw data signal, with a mean frequency of 0.36 Hz ± 0.06. The results of this study indicate that image artifacts caused by heart rate variations within the imaging period are predictable and may be reduced by correcting signal intensity for each phase view before two-dimensional Fourier transformation.

Original languageEnglish (US)
Pages (from-to)883-887
Number of pages5
JournalRadiology
Volume186
Issue number3
StatePublished - Mar 1993

Fingerprint

Artifacts
Heart Rate
Respiratory Rate
Healthy Volunteers
Magnetic Resonance Spectroscopy
Magnetic Resonance Imaging
Direction compound

Keywords

  • Heart, MR, 51.1214
  • Images, artifact, 51.1214
  • Magnetic resonance (MR), artifact, 51.1214
  • Magnetic resonance (MR), technology

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Effect of RR interval variation on image quality in gated, two-dimensional, fourier MR imaging. / Rogers, Walter J.; Shapiro, Edward.

In: Radiology, Vol. 186, No. 3, 03.1993, p. 883-887.

Research output: Contribution to journalArticle

@article{c1655c8e275c4dacb17e04fae1a4673b,
title = "Effect of RR interval variation on image quality in gated, two-dimensional, fourier MR imaging",
abstract = "The effect of uneven repetition time (TR) intervals on artifact production during gated two-dimensional Fourier magnetic resonance image acquisition was investigated and a means of compensation presented. In standard spin-echo imaging, incomplete longitudinal recovery combines with normal respiratory heart rate variations to modulate signal intensity and create image copies and smearing along the phase direction. Modulation amplitude, frequency, and pattern, as well as machine parameters including echo time, TR, field of view, and image matrix size, have been found to have a substantial impact on artifact position and intensity. In a group of 10 healthy volunteers, respiratory-induced heart rate modulation produced an average of 17.2{\%} ± 4.9 variation in the raw data signal, with a mean frequency of 0.36 Hz ± 0.06. The results of this study indicate that image artifacts caused by heart rate variations within the imaging period are predictable and may be reduced by correcting signal intensity for each phase view before two-dimensional Fourier transformation.",
keywords = "Heart, MR, 51.1214, Images, artifact, 51.1214, Magnetic resonance (MR), artifact, 51.1214, Magnetic resonance (MR), technology",
author = "Rogers, {Walter J.} and Edward Shapiro",
year = "1993",
month = "3",
language = "English (US)",
volume = "186",
pages = "883--887",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "3",

}

TY - JOUR

T1 - Effect of RR interval variation on image quality in gated, two-dimensional, fourier MR imaging

AU - Rogers, Walter J.

AU - Shapiro, Edward

PY - 1993/3

Y1 - 1993/3

N2 - The effect of uneven repetition time (TR) intervals on artifact production during gated two-dimensional Fourier magnetic resonance image acquisition was investigated and a means of compensation presented. In standard spin-echo imaging, incomplete longitudinal recovery combines with normal respiratory heart rate variations to modulate signal intensity and create image copies and smearing along the phase direction. Modulation amplitude, frequency, and pattern, as well as machine parameters including echo time, TR, field of view, and image matrix size, have been found to have a substantial impact on artifact position and intensity. In a group of 10 healthy volunteers, respiratory-induced heart rate modulation produced an average of 17.2% ± 4.9 variation in the raw data signal, with a mean frequency of 0.36 Hz ± 0.06. The results of this study indicate that image artifacts caused by heart rate variations within the imaging period are predictable and may be reduced by correcting signal intensity for each phase view before two-dimensional Fourier transformation.

AB - The effect of uneven repetition time (TR) intervals on artifact production during gated two-dimensional Fourier magnetic resonance image acquisition was investigated and a means of compensation presented. In standard spin-echo imaging, incomplete longitudinal recovery combines with normal respiratory heart rate variations to modulate signal intensity and create image copies and smearing along the phase direction. Modulation amplitude, frequency, and pattern, as well as machine parameters including echo time, TR, field of view, and image matrix size, have been found to have a substantial impact on artifact position and intensity. In a group of 10 healthy volunteers, respiratory-induced heart rate modulation produced an average of 17.2% ± 4.9 variation in the raw data signal, with a mean frequency of 0.36 Hz ± 0.06. The results of this study indicate that image artifacts caused by heart rate variations within the imaging period are predictable and may be reduced by correcting signal intensity for each phase view before two-dimensional Fourier transformation.

KW - Heart, MR, 51.1214

KW - Images, artifact, 51.1214

KW - Magnetic resonance (MR), artifact, 51.1214

KW - Magnetic resonance (MR), technology