Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols

W. Paul Segars, Benjamin Tsui

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Artifacts can arise in reconstructed SPECT images using CT-based attenuation correction (CTAC) due to patient respiratory motion. We investigate the extent of these artifacts using different CT scanners ranging from single-slice to state-of-the-art multi-slice units. The 4D NCAT phantom was used to realistically model different patient respiratory patterns (breathhold, shallow, normal, and deep breathing). In-111 ProstaScint® and Tc-99m Sestamibi SPECT emission projection data including the effects of attenuation, collimator-detector response and scatter were simulated from the phantoms. CT images were generated using different CT scanners with varying rotation speeds (0.5 to 14 sec/rotation). The CT data were converted into attenuation maps and used to reconstruct the emission projections with attenuation correction (AC). In each case, the CT-based AC SPECT images (with and without artifacts) were compared to assess the effect of the respiratory motion. CT respiratory artifacts were found to increase with slower rotation speeds and to affect the SPECT reconstructions using CTAC. Though less susceptible to respiratory motion, the fastest CT scanner was still found to result in artifacts in the SPECT images due to the mismatch between the CT (∼breathhold) and SPECT (average motion) data. In both cases (CT motion and CT-SPECT mismatch), the artifacts were reduced using a shallow breathing pattern. We conclude that respiratory motion is an important consideration in SPECT-CT imaging when using CT-based AC. Careful work must be done to design protocols to reduce CT artifacts while minimizing the mismatch between the CT and SPECT data.

Original languageEnglish (US)
Title of host publicationIEEE Nuclear Science Symposium Conference Record
Pages2413-2417
Number of pages5
Volume4
DOIs
StatePublished - 2005
EventNuclear Science Symposium Conference Record, 2005 IEEE - , Puerto Rico
Duration: Oct 23 2005Oct 29 2005

Other

OtherNuclear Science Symposium Conference Record, 2005 IEEE
CountryPuerto Rico
Period10/23/0510/29/05

Fingerprint

Detectors
Imaging techniques

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols. / Segars, W. Paul; Tsui, Benjamin.

IEEE Nuclear Science Symposium Conference Record. Vol. 4 2005. p. 2413-2417 1596819.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Segars, WP & Tsui, B 2005, Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols. in IEEE Nuclear Science Symposium Conference Record. vol. 4, 1596819, pp. 2413-2417, Nuclear Science Symposium Conference Record, 2005 IEEE, Puerto Rico, 10/23/05. https://doi.org/10.1109/NSSMIC.2005.1596819
Segars, W. Paul ; Tsui, Benjamin. / Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols. IEEE Nuclear Science Symposium Conference Record. Vol. 4 2005. pp. 2413-2417
@inproceedings{990d2da8e5ae49e89742013216059b06,
title = "Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols",
abstract = "Artifacts can arise in reconstructed SPECT images using CT-based attenuation correction (CTAC) due to patient respiratory motion. We investigate the extent of these artifacts using different CT scanners ranging from single-slice to state-of-the-art multi-slice units. The 4D NCAT phantom was used to realistically model different patient respiratory patterns (breathhold, shallow, normal, and deep breathing). In-111 ProstaScint{\circledR} and Tc-99m Sestamibi SPECT emission projection data including the effects of attenuation, collimator-detector response and scatter were simulated from the phantoms. CT images were generated using different CT scanners with varying rotation speeds (0.5 to 14 sec/rotation). The CT data were converted into attenuation maps and used to reconstruct the emission projections with attenuation correction (AC). In each case, the CT-based AC SPECT images (with and without artifacts) were compared to assess the effect of the respiratory motion. CT respiratory artifacts were found to increase with slower rotation speeds and to affect the SPECT reconstructions using CTAC. Though less susceptible to respiratory motion, the fastest CT scanner was still found to result in artifacts in the SPECT images due to the mismatch between the CT (∼breathhold) and SPECT (average motion) data. In both cases (CT motion and CT-SPECT mismatch), the artifacts were reduced using a shallow breathing pattern. We conclude that respiratory motion is an important consideration in SPECT-CT imaging when using CT-based AC. Careful work must be done to design protocols to reduce CT artifacts while minimizing the mismatch between the CT and SPECT data.",
author = "Segars, {W. Paul} and Benjamin Tsui",
year = "2005",
doi = "10.1109/NSSMIC.2005.1596819",
language = "English (US)",
isbn = "0780392213",
volume = "4",
pages = "2413--2417",
booktitle = "IEEE Nuclear Science Symposium Conference Record",

}

TY - GEN

T1 - Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols

AU - Segars, W. Paul

AU - Tsui, Benjamin

PY - 2005

Y1 - 2005

N2 - Artifacts can arise in reconstructed SPECT images using CT-based attenuation correction (CTAC) due to patient respiratory motion. We investigate the extent of these artifacts using different CT scanners ranging from single-slice to state-of-the-art multi-slice units. The 4D NCAT phantom was used to realistically model different patient respiratory patterns (breathhold, shallow, normal, and deep breathing). In-111 ProstaScint® and Tc-99m Sestamibi SPECT emission projection data including the effects of attenuation, collimator-detector response and scatter were simulated from the phantoms. CT images were generated using different CT scanners with varying rotation speeds (0.5 to 14 sec/rotation). The CT data were converted into attenuation maps and used to reconstruct the emission projections with attenuation correction (AC). In each case, the CT-based AC SPECT images (with and without artifacts) were compared to assess the effect of the respiratory motion. CT respiratory artifacts were found to increase with slower rotation speeds and to affect the SPECT reconstructions using CTAC. Though less susceptible to respiratory motion, the fastest CT scanner was still found to result in artifacts in the SPECT images due to the mismatch between the CT (∼breathhold) and SPECT (average motion) data. In both cases (CT motion and CT-SPECT mismatch), the artifacts were reduced using a shallow breathing pattern. We conclude that respiratory motion is an important consideration in SPECT-CT imaging when using CT-based AC. Careful work must be done to design protocols to reduce CT artifacts while minimizing the mismatch between the CT and SPECT data.

AB - Artifacts can arise in reconstructed SPECT images using CT-based attenuation correction (CTAC) due to patient respiratory motion. We investigate the extent of these artifacts using different CT scanners ranging from single-slice to state-of-the-art multi-slice units. The 4D NCAT phantom was used to realistically model different patient respiratory patterns (breathhold, shallow, normal, and deep breathing). In-111 ProstaScint® and Tc-99m Sestamibi SPECT emission projection data including the effects of attenuation, collimator-detector response and scatter were simulated from the phantoms. CT images were generated using different CT scanners with varying rotation speeds (0.5 to 14 sec/rotation). The CT data were converted into attenuation maps and used to reconstruct the emission projections with attenuation correction (AC). In each case, the CT-based AC SPECT images (with and without artifacts) were compared to assess the effect of the respiratory motion. CT respiratory artifacts were found to increase with slower rotation speeds and to affect the SPECT reconstructions using CTAC. Though less susceptible to respiratory motion, the fastest CT scanner was still found to result in artifacts in the SPECT images due to the mismatch between the CT (∼breathhold) and SPECT (average motion) data. In both cases (CT motion and CT-SPECT mismatch), the artifacts were reduced using a shallow breathing pattern. We conclude that respiratory motion is an important consideration in SPECT-CT imaging when using CT-based AC. Careful work must be done to design protocols to reduce CT artifacts while minimizing the mismatch between the CT and SPECT data.

UR - http://www.scopus.com/inward/record.url?scp=33846595359&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846595359&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2005.1596819

DO - 10.1109/NSSMIC.2005.1596819

M3 - Conference contribution

AN - SCOPUS:33846595359

SN - 0780392213

SN - 9780780392212

VL - 4

SP - 2413

EP - 2417

BT - IEEE Nuclear Science Symposium Conference Record

ER -