Effect of external pressure pulses on the flow in a collapsible tube crossing a flexible membrane. Simulation of a large blood vessel subjected to chest and abdominal phased compression.

E. Kimmel, S. Sideman, U. Dinnar, R. Beyar

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Pulsed flow in an elastic tube through two rigid water filled chambers separated by an elastic membrane was studied. The device simulates a main blood vessel traversing the diaphragm from the chest to the abdomen and subjected to sequential compressions of the abdomen and chest as is the case in phased compression cardiopulmonary resuscitation (PCCPR). (from authors' abstract)

Original languageEnglish (US)
Title of host publicationUnknown Host Publication Title
PublisherMexicoUniv. Nat. Autonom
ISBN (Print)9688372056, 9789688372050
StatePublished - 1984
Externally publishedYes

Fingerprint

Collapsible tubes
Resuscitation
Pulsatile flow
Blood vessels
Diaphragms
Membranes
Water

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Effect of external pressure pulses on the flow in a collapsible tube crossing a flexible membrane. Simulation of a large blood vessel subjected to chest and abdominal phased compression. / Kimmel, E.; Sideman, S.; Dinnar, U.; Beyar, R.

Unknown Host Publication Title. MexicoUniv. Nat. Autonom, 1984.

Research output: Chapter in Book/Report/Conference proceedingChapter

@inbook{561d93ec5b0840e7b67fc7466880c659,
title = "Effect of external pressure pulses on the flow in a collapsible tube crossing a flexible membrane. Simulation of a large blood vessel subjected to chest and abdominal phased compression.",
abstract = "Pulsed flow in an elastic tube through two rigid water filled chambers separated by an elastic membrane was studied. The device simulates a main blood vessel traversing the diaphragm from the chest to the abdomen and subjected to sequential compressions of the abdomen and chest as is the case in phased compression cardiopulmonary resuscitation (PCCPR). (from authors' abstract)",
author = "E. Kimmel and S. Sideman and U. Dinnar and R. Beyar",
year = "1984",
language = "English (US)",
isbn = "9688372056",
booktitle = "Unknown Host Publication Title",
publisher = "MexicoUniv. Nat. Autonom",

}

TY - CHAP

T1 - Effect of external pressure pulses on the flow in a collapsible tube crossing a flexible membrane. Simulation of a large blood vessel subjected to chest and abdominal phased compression.

AU - Kimmel, E.

AU - Sideman, S.

AU - Dinnar, U.

AU - Beyar, R.

PY - 1984

Y1 - 1984

N2 - Pulsed flow in an elastic tube through two rigid water filled chambers separated by an elastic membrane was studied. The device simulates a main blood vessel traversing the diaphragm from the chest to the abdomen and subjected to sequential compressions of the abdomen and chest as is the case in phased compression cardiopulmonary resuscitation (PCCPR). (from authors' abstract)

AB - Pulsed flow in an elastic tube through two rigid water filled chambers separated by an elastic membrane was studied. The device simulates a main blood vessel traversing the diaphragm from the chest to the abdomen and subjected to sequential compressions of the abdomen and chest as is the case in phased compression cardiopulmonary resuscitation (PCCPR). (from authors' abstract)

UR - http://www.scopus.com/inward/record.url?scp=0021126619&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021126619&partnerID=8YFLogxK

M3 - Chapter

SN - 9688372056

SN - 9789688372050

BT - Unknown Host Publication Title

PB - MexicoUniv. Nat. Autonom

ER -