Effect of contrast concentration on abdominal enhancement in the rabbit: Spiral computed tomography evaluation

David A. Bluemke, Elliot K Fishman, James H. Anderson

Research output: Contribution to journalArticle

Abstract

Rationale and Objectives.: We examined the effect of varying the concentration of a nonionic iodinated contrast agent on hepatic and abdominal vascular enhancement using spiral computed tomography (CT) scanning. Methods.: Spiral CT scans of 10 New Zealand male rabbits were obtained after intravenous injection of 240 mg I/ml iohexol and 350 mg I/ml iohexol injected at a rate of 2 ml/sec. Each animal was studied at both concentrations using four different contrast volumes: 2.3, 1.7, 1.1, and 0.57 ml/kg. Enhancement values of the aorta, hepatic veins, inferior vena cava, and hepatic parenchyma were measured using a region-of-interest cursor. Results.: At all contrast doses, equal volumes of contrast iohexol-350 resulted in statistically higher hepatic (p ≤ .003, paired Student's t test) as well as vascular (p <.04) enhancement compared with iohexol-240. The slopes and intercepts of the enhancement curves for iohexol-350 and iohexol-240 were not statistically different (p >> .05) when enhancement was plotted as a function of total grams of iodine administered. Conclusion.: With spiral CT scanning, appropriate contrast doses and relative costs per dose of iohexol should be considered on the basis of total iodine load administered rather than total volume administered.

Original languageEnglish (US)
Pages (from-to)226-231
Number of pages6
JournalAcademic Radiology
Volume2
Issue number3
DOIs
StatePublished - 1995

Fingerprint

Iohexol
Spiral Computed Tomography
Rabbits
Iodine
Blood Vessels
Liver
Hepatic Veins
Inferior Vena Cava
Intravenous Injections
Contrast Media
Aorta
Students
Costs and Cost Analysis

Keywords

  • Computed tomography (CT)
  • contrast media
  • helical (spiral) technology
  • liver CT

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Effect of contrast concentration on abdominal enhancement in the rabbit : Spiral computed tomography evaluation. / Bluemke, David A.; Fishman, Elliot K; Anderson, James H.

In: Academic Radiology, Vol. 2, No. 3, 1995, p. 226-231.

Research output: Contribution to journalArticle

@article{531a425acd064defaaa2015260a089a0,
title = "Effect of contrast concentration on abdominal enhancement in the rabbit: Spiral computed tomography evaluation",
abstract = "Rationale and Objectives.: We examined the effect of varying the concentration of a nonionic iodinated contrast agent on hepatic and abdominal vascular enhancement using spiral computed tomography (CT) scanning. Methods.: Spiral CT scans of 10 New Zealand male rabbits were obtained after intravenous injection of 240 mg I/ml iohexol and 350 mg I/ml iohexol injected at a rate of 2 ml/sec. Each animal was studied at both concentrations using four different contrast volumes: 2.3, 1.7, 1.1, and 0.57 ml/kg. Enhancement values of the aorta, hepatic veins, inferior vena cava, and hepatic parenchyma were measured using a region-of-interest cursor. Results.: At all contrast doses, equal volumes of contrast iohexol-350 resulted in statistically higher hepatic (p ≤ .003, paired Student's t test) as well as vascular (p <.04) enhancement compared with iohexol-240. The slopes and intercepts of the enhancement curves for iohexol-350 and iohexol-240 were not statistically different (p >> .05) when enhancement was plotted as a function of total grams of iodine administered. Conclusion.: With spiral CT scanning, appropriate contrast doses and relative costs per dose of iohexol should be considered on the basis of total iodine load administered rather than total volume administered.",
keywords = "Computed tomography (CT), contrast media, helical (spiral) technology, liver CT",
author = "Bluemke, {David A.} and Fishman, {Elliot K} and Anderson, {James H.}",
year = "1995",
doi = "10.1016/S1076-6332(05)80170-9",
language = "English (US)",
volume = "2",
pages = "226--231",
journal = "Academic Radiology",
issn = "1076-6332",
publisher = "Elsevier USA",
number = "3",

}

TY - JOUR

T1 - Effect of contrast concentration on abdominal enhancement in the rabbit

T2 - Spiral computed tomography evaluation

AU - Bluemke, David A.

AU - Fishman, Elliot K

AU - Anderson, James H.

PY - 1995

Y1 - 1995

N2 - Rationale and Objectives.: We examined the effect of varying the concentration of a nonionic iodinated contrast agent on hepatic and abdominal vascular enhancement using spiral computed tomography (CT) scanning. Methods.: Spiral CT scans of 10 New Zealand male rabbits were obtained after intravenous injection of 240 mg I/ml iohexol and 350 mg I/ml iohexol injected at a rate of 2 ml/sec. Each animal was studied at both concentrations using four different contrast volumes: 2.3, 1.7, 1.1, and 0.57 ml/kg. Enhancement values of the aorta, hepatic veins, inferior vena cava, and hepatic parenchyma were measured using a region-of-interest cursor. Results.: At all contrast doses, equal volumes of contrast iohexol-350 resulted in statistically higher hepatic (p ≤ .003, paired Student's t test) as well as vascular (p <.04) enhancement compared with iohexol-240. The slopes and intercepts of the enhancement curves for iohexol-350 and iohexol-240 were not statistically different (p >> .05) when enhancement was plotted as a function of total grams of iodine administered. Conclusion.: With spiral CT scanning, appropriate contrast doses and relative costs per dose of iohexol should be considered on the basis of total iodine load administered rather than total volume administered.

AB - Rationale and Objectives.: We examined the effect of varying the concentration of a nonionic iodinated contrast agent on hepatic and abdominal vascular enhancement using spiral computed tomography (CT) scanning. Methods.: Spiral CT scans of 10 New Zealand male rabbits were obtained after intravenous injection of 240 mg I/ml iohexol and 350 mg I/ml iohexol injected at a rate of 2 ml/sec. Each animal was studied at both concentrations using four different contrast volumes: 2.3, 1.7, 1.1, and 0.57 ml/kg. Enhancement values of the aorta, hepatic veins, inferior vena cava, and hepatic parenchyma were measured using a region-of-interest cursor. Results.: At all contrast doses, equal volumes of contrast iohexol-350 resulted in statistically higher hepatic (p ≤ .003, paired Student's t test) as well as vascular (p <.04) enhancement compared with iohexol-240. The slopes and intercepts of the enhancement curves for iohexol-350 and iohexol-240 were not statistically different (p >> .05) when enhancement was plotted as a function of total grams of iodine administered. Conclusion.: With spiral CT scanning, appropriate contrast doses and relative costs per dose of iohexol should be considered on the basis of total iodine load administered rather than total volume administered.

KW - Computed tomography (CT)

KW - contrast media

KW - helical (spiral) technology

KW - liver CT

UR - http://www.scopus.com/inward/record.url?scp=0029257729&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029257729&partnerID=8YFLogxK

U2 - 10.1016/S1076-6332(05)80170-9

DO - 10.1016/S1076-6332(05)80170-9

M3 - Article

C2 - 9419553

AN - SCOPUS:0029257729

VL - 2

SP - 226

EP - 231

JO - Academic Radiology

JF - Academic Radiology

SN - 1076-6332

IS - 3

ER -