Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy

Georg Oeltzschner, Nicolaas A J Puts, Kimberly L. Chan, Vincent O. Boer, Peter B. Barker, Richard A E Edden

Research output: Contribution to journalArticle

Abstract

Purpose: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. Methods: PRIAM separates signals from two simultaneously excited voxels using receiver-coil sensitivity profiles. PRIAM was implemented into Mescher-Garwood (MEGA) edited experiments at 3 Tesla (T), and validated by acquiring dual-voxel MEGA-PRIAM (and compared with conventional single-voxel MEGA-PRESS) spectra from a GABA/glutathione phantom, and 11 healthy participants. Results: MEGA-PRIAM effectively separated phantom spectra with ∼3–4% between-voxel contamination. GABA and glutathione measurements agreed well with those obtained using single-voxel MEGA-PRESS (mean difference was below 2% in GABA levels, and below 7% in glutathione levels). In vivo, GABA- and glutathione-edited spectra were successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7–8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). Conclusions: Simultaneous acquisition of J-difference-edited GABA or glutathione spectra from two voxels is feasible at 3 T. MEGA-PRIAM increases data acquisition rates compared with MEGA-PRESS by a factor of 2. Magn Reson Med 77:16–22, 2017.

Original languageEnglish (US)
Pages (from-to)16-22
Number of pages7
JournalMagnetic Resonance in Medicine
Volume77
Issue number1
DOIs
StatePublished - Jan 1 2017

Fingerprint

gamma-Aminobutyric Acid
Magnetic Resonance Spectroscopy
Glutathione
Signal-To-Noise Ratio
Healthy Volunteers
Brain

Keywords

  • brain
  • dual volume
  • edited MRS
  • GABA
  • GSH
  • multivoxel

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy. / Oeltzschner, Georg; Puts, Nicolaas A J; Chan, Kimberly L.; Boer, Vincent O.; Barker, Peter B.; Edden, Richard A E.

In: Magnetic Resonance in Medicine, Vol. 77, No. 1, 01.01.2017, p. 16-22.

Research output: Contribution to journalArticle

Oeltzschner, Georg; Puts, Nicolaas A J; Chan, Kimberly L.; Boer, Vincent O.; Barker, Peter B.; Edden, Richard A E / Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy.

In: Magnetic Resonance in Medicine, Vol. 77, No. 1, 01.01.2017, p. 16-22.

Research output: Contribution to journalArticle

@article{7ae7d023d05a46a0b0f1ed093ef9ffd5,
title = "Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy",
abstract = "Purpose: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. Methods: PRIAM separates signals from two simultaneously excited voxels using receiver-coil sensitivity profiles. PRIAM was implemented into Mescher-Garwood (MEGA) edited experiments at 3 Tesla (T), and validated by acquiring dual-voxel MEGA-PRIAM (and compared with conventional single-voxel MEGA-PRESS) spectra from a GABA/glutathione phantom, and 11 healthy participants. Results: MEGA-PRIAM effectively separated phantom spectra with ∼3–4% between-voxel contamination. GABA and glutathione measurements agreed well with those obtained using single-voxel MEGA-PRESS (mean difference was below 2% in GABA levels, and below 7% in glutathione levels). In vivo, GABA- and glutathione-edited spectra were successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7–8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). Conclusions: Simultaneous acquisition of J-difference-edited GABA or glutathione spectra from two voxels is feasible at 3 T. MEGA-PRIAM increases data acquisition rates compared with MEGA-PRESS by a factor of 2. Magn Reson Med 77:16–22, 2017.",
keywords = "brain, dual volume, edited MRS, GABA, GSH, multivoxel",
author = "Georg Oeltzschner and Puts, {Nicolaas A J} and Chan, {Kimberly L.} and Boer, {Vincent O.} and Barker, {Peter B.} and Edden, {Richard A E}",
year = "2017",
month = "1",
doi = "10.1002/mrm.26536",
volume = "77",
pages = "16--22",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy

AU - Oeltzschner,Georg

AU - Puts,Nicolaas A J

AU - Chan,Kimberly L.

AU - Boer,Vincent O.

AU - Barker,Peter B.

AU - Edden,Richard A E

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Purpose: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. Methods: PRIAM separates signals from two simultaneously excited voxels using receiver-coil sensitivity profiles. PRIAM was implemented into Mescher-Garwood (MEGA) edited experiments at 3 Tesla (T), and validated by acquiring dual-voxel MEGA-PRIAM (and compared with conventional single-voxel MEGA-PRESS) spectra from a GABA/glutathione phantom, and 11 healthy participants. Results: MEGA-PRIAM effectively separated phantom spectra with ∼3–4% between-voxel contamination. GABA and glutathione measurements agreed well with those obtained using single-voxel MEGA-PRESS (mean difference was below 2% in GABA levels, and below 7% in glutathione levels). In vivo, GABA- and glutathione-edited spectra were successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7–8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). Conclusions: Simultaneous acquisition of J-difference-edited GABA or glutathione spectra from two voxels is feasible at 3 T. MEGA-PRIAM increases data acquisition rates compared with MEGA-PRESS by a factor of 2. Magn Reson Med 77:16–22, 2017.

AB - Purpose: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. Methods: PRIAM separates signals from two simultaneously excited voxels using receiver-coil sensitivity profiles. PRIAM was implemented into Mescher-Garwood (MEGA) edited experiments at 3 Tesla (T), and validated by acquiring dual-voxel MEGA-PRIAM (and compared with conventional single-voxel MEGA-PRESS) spectra from a GABA/glutathione phantom, and 11 healthy participants. Results: MEGA-PRIAM effectively separated phantom spectra with ∼3–4% between-voxel contamination. GABA and glutathione measurements agreed well with those obtained using single-voxel MEGA-PRESS (mean difference was below 2% in GABA levels, and below 7% in glutathione levels). In vivo, GABA- and glutathione-edited spectra were successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7–8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). Conclusions: Simultaneous acquisition of J-difference-edited GABA or glutathione spectra from two voxels is feasible at 3 T. MEGA-PRIAM increases data acquisition rates compared with MEGA-PRESS by a factor of 2. Magn Reson Med 77:16–22, 2017.

KW - brain

KW - dual volume

KW - edited MRS

KW - GABA

KW - GSH

KW - multivoxel

UR - http://www.scopus.com/inward/record.url?scp=84999622263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84999622263&partnerID=8YFLogxK

U2 - 10.1002/mrm.26536

DO - 10.1002/mrm.26536

M3 - Article

VL - 77

SP - 16

EP - 22

JO - Magnetic Resonance in Medicine

T2 - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -