The movement of tympanic membranes can be evaluated with a video pneumatic otoscopy using otoendoscope and video apparatus. The umbo position was analyzed using template matching method when the pressure inside of it was static, positive and negative, respectively. The template matching method was used to track and measure the movement of tympanic membranes automatically. This method is more comfortable in uses, more accurate and precision compare with manual method. Moreover we can reduce the analysis time and improve the objectivity of measurement with the proposed method.

Original languageEnglish (US)
Title of host publication5th 2012 Biomedical Engineering International Conference, BMEiCON 2012
DOIs
StatePublished - 2012
Externally publishedYes
Event5th 2012 Biomedical Engineering International Conference, BMEiCON 2012 - Muang, Ubon Ratchathani, Thailand
Duration: Dec 5 2012Dec 7 2012

Other

Other5th 2012 Biomedical Engineering International Conference, BMEiCON 2012
CountryThailand
CityMuang, Ubon Ratchathani
Period12/5/1212/7/12

Fingerprint

Template matching
Audition
Membranes
Pneumatics

Keywords

  • Pneumatic otoscope
  • Template matching
  • Tympanic membrane movements
  • Umbo

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Anumas, S., Cho, Y., Han, G., & Kim, S. (2012). Diagnosis of conductive hearing loss using template matching method. In 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012 [6465504] https://doi.org/10.1109/BMEiCon.2012.6465504

Diagnosis of conductive hearing loss using template matching method. / Anumas, Sasiporn; Cho, Yangsun; Han, Gyucheol; Kim, Soochan.

5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012. 6465504.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Anumas, S, Cho, Y, Han, G & Kim, S 2012, Diagnosis of conductive hearing loss using template matching method. in 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012., 6465504, 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012, Muang, Ubon Ratchathani, Thailand, 12/5/12. https://doi.org/10.1109/BMEiCon.2012.6465504
Anumas S, Cho Y, Han G, Kim S. Diagnosis of conductive hearing loss using template matching method. In 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012. 6465504 https://doi.org/10.1109/BMEiCon.2012.6465504
Anumas, Sasiporn ; Cho, Yangsun ; Han, Gyucheol ; Kim, Soochan. / Diagnosis of conductive hearing loss using template matching method. 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012.
@inproceedings{cc93dc8f5ed84b1aaa86e7e2196b1ab8,
title = "Diagnosis of conductive hearing loss using template matching method",
abstract = "The movement of tympanic membranes can be evaluated with a video pneumatic otoscopy using otoendoscope and video apparatus. The umbo position was analyzed using template matching method when the pressure inside of it was static, positive and negative, respectively. The template matching method was used to track and measure the movement of tympanic membranes automatically. This method is more comfortable in uses, more accurate and precision compare with manual method. Moreover we can reduce the analysis time and improve the objectivity of measurement with the proposed method.",
keywords = "Pneumatic otoscope, Template matching, Tympanic membrane movements, Umbo",
author = "Sasiporn Anumas and Yangsun Cho and Gyucheol Han and Soochan Kim",
year = "2012",
doi = "10.1109/BMEiCon.2012.6465504",
language = "English (US)",
isbn = "9781467348928",
booktitle = "5th 2012 Biomedical Engineering International Conference, BMEiCON 2012",

}

TY - GEN

T1 - Diagnosis of conductive hearing loss using template matching method

AU - Anumas, Sasiporn

AU - Cho, Yangsun

AU - Han, Gyucheol

AU - Kim, Soochan

PY - 2012

Y1 - 2012

N2 - The movement of tympanic membranes can be evaluated with a video pneumatic otoscopy using otoendoscope and video apparatus. The umbo position was analyzed using template matching method when the pressure inside of it was static, positive and negative, respectively. The template matching method was used to track and measure the movement of tympanic membranes automatically. This method is more comfortable in uses, more accurate and precision compare with manual method. Moreover we can reduce the analysis time and improve the objectivity of measurement with the proposed method.

AB - The movement of tympanic membranes can be evaluated with a video pneumatic otoscopy using otoendoscope and video apparatus. The umbo position was analyzed using template matching method when the pressure inside of it was static, positive and negative, respectively. The template matching method was used to track and measure the movement of tympanic membranes automatically. This method is more comfortable in uses, more accurate and precision compare with manual method. Moreover we can reduce the analysis time and improve the objectivity of measurement with the proposed method.

KW - Pneumatic otoscope

KW - Template matching

KW - Tympanic membrane movements

KW - Umbo

UR - http://www.scopus.com/inward/record.url?scp=84875103367&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875103367&partnerID=8YFLogxK

U2 - 10.1109/BMEiCon.2012.6465504

DO - 10.1109/BMEiCon.2012.6465504

M3 - Conference contribution

SN - 9781467348928

BT - 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012

ER -