Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment

Harikrishna Tandri, Menekhem M. Zviman, Steven R. Wedan, Thomas Lloyd, Ronald D. Berger, Henry Halperin

Research output: Contribution to journalArticle

Abstract

Background: The determinants of low-frequency-induced current by magnetic resonance imaging (MRI) gradient fields in a pacemaker lead system are largely unknown. Objective: The purpose of this study was to determine the magnitude of MRI low-frequency-induced current in an implanted pacemaker lead system and to investigate in vivo determinants of low-frequency-induced current in an animal model. Methods: Six mongrel dogs underwent conventional single-chamber pacemaker implantation with a current recorder connected in series. Pulse generator (PG) was programmed to VOO 120 bpm with subthreshold output. MRI was performed in a 1.5-T scanner. Low-frequency-induced current was recorded during unipolar pacing, bipolar pacing, and bipolar pacing with the PG case electrically isolated from the pocket. In each mode, low-frequency-induced current was recorded with and without a large loop of additional lead connected in series. Results: With a conventional implant, low-frequency-induced current was ≤0.5 mA in all three pacing modes. With five external loops, the magnitude of low-frequency-induced current increased to >30 mA, with consistent myocardial capture in unipolar and bipolar pacing. However, in bipolar pacing with the PG electrically isolated from the pocket, low-frequency-induced current decreased to <0.5 mA with no myocardial capture even with additional looped leads. Conclusion: Under conventional implant conditions, the magnitude of low-frequency-induced current is <0.5 mA and is unlikely to cause myocardial capture; however, arrhythmia induction cannot be excluded. With sufficient increase in effective loop area (additional looped leads), direct myocardial capture by the low-frequency-induced current is possible. In this study, breaking the return pathway by electrically isolating the PG case from the circuit abolished low-frequency-induced current.

Original languageEnglish (US)
Pages (from-to)462-468
Number of pages7
JournalHeart Rhythm
Volume5
Issue number3
DOIs
StatePublished - Mar 1 2008

    Fingerprint

Keywords

  • Determinants
  • Induced current
  • Interaction
  • Magnetic resonance imaging
  • Pacemaker

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this