TY - JOUR
T1 - Detection of intracranial internal carotid artery and middle cerebral artery vasospasm following subarachnoid hemorrhage
AU - Burch, Christina M.
AU - Wozniak, Marcella A.
AU - Sloan, Michael A.
AU - Rothman, Michael I.
AU - Rigamonti, Daniele
AU - Permutt, Thomas
AU - Numaguchi, Yuji
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1996
Y1 - 1996
N2 - Little is known about the accuracy of transcranial Doppler (TED) sonography in detecting intracranial internal carotid artery (IICA) and middle cerebral artery (MCA) vasospasm. TCD was performed in 49 patients with subarachnoid hemorrhage to evaluate 90 IICAs and 87 MCAs during the vasospasm period. When a mean velocity of at least 90 cm/sec was used to indicate IICA vasospasm, there were 11 positive, 42 negative, 4 false-positive, and 33 false-negative results. Sensitivity was 25% and specificity was 93%. When a mean velocity of at least 120 cm/sec was used to indicate MCA vasospasm, there were 15 positive, 45 negative, 3 false-positive, and 24 false negative results (15 operator errors). Sensitivity was 38.5% and specificity was 93.7%. When the diagnostic criterion was changed to at least 130 cm/see, specificities were 100% (IICA) and 96% (MCA) and positive predictive values were 100% (IICA) and 87% (MCA). The authors conclude that TCD accurately detects IICA and MCA vasospasm when flow velocities are at least 130 cm/sec. However, its sensitivity may be underestimated and the importance of operator error, overestimated
AB - Little is known about the accuracy of transcranial Doppler (TED) sonography in detecting intracranial internal carotid artery (IICA) and middle cerebral artery (MCA) vasospasm. TCD was performed in 49 patients with subarachnoid hemorrhage to evaluate 90 IICAs and 87 MCAs during the vasospasm period. When a mean velocity of at least 90 cm/sec was used to indicate IICA vasospasm, there were 11 positive, 42 negative, 4 false-positive, and 33 false-negative results. Sensitivity was 25% and specificity was 93%. When a mean velocity of at least 120 cm/sec was used to indicate MCA vasospasm, there were 15 positive, 45 negative, 3 false-positive, and 24 false negative results (15 operator errors). Sensitivity was 38.5% and specificity was 93.7%. When the diagnostic criterion was changed to at least 130 cm/see, specificities were 100% (IICA) and 96% (MCA) and positive predictive values were 100% (IICA) and 87% (MCA). The authors conclude that TCD accurately detects IICA and MCA vasospasm when flow velocities are at least 130 cm/sec. However, its sensitivity may be underestimated and the importance of operator error, overestimated
UR - http://www.scopus.com/inward/record.url?scp=0030039382&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030039382&partnerID=8YFLogxK
U2 - 10.1111/jon1996618
DO - 10.1111/jon1996618
M3 - Article
C2 - 8555669
AN - SCOPUS:0030039382
VL - 6
SP - 8
EP - 15
JO - Journal of Neuroimaging
JF - Journal of Neuroimaging
SN - 1051-2284
IS - 1
ER -