Objective. We aimed to increase detection of pediatric cardiopulmonary resuscitation (CPR) events and collection of physiologic and performance data for use in quality improvement (QI) efforts. Materials and Methods. We developed a workflow-driven surveillance system that leveraged organizational information technology systems to trigger CPR detection and analysis processes. We characterized detection by notification source, type, location, and year, and compared it to previous methods of detection. Results. From 1/1/2013 through 12/31/2015, there were 2,986 unique notifications associated with 2,145 events, 317 requiring CPR. PICU and PEDS-ED accounted for 65% of CPR events, whereas floor care areas were responsible for only 3% of events. 100% of PEDS-OR and >70% of PICU CPR events would not have been included in QI efforts. Performance data from both defibrillator and bedside monitor increased annually. (2013: 1%; 2014: 18%; 2015: 27%). Discussion. After deployment of this system, detection has increased ∼9-fold and performance data collection increased annually. Had the system not been deployed, 100% of PEDS-OR and 50-70% of PICU, NICU, and PEDS-ED events would have been missed. Conclusion. By leveraging hospital information technology and medical device data, identification of pediatric cardiac arrest with an associated increased capture in the proportion of objective performance data is possible.

Original languageEnglish (US)
Article number9187962
JournalCritical Care Research and Practice
Volume2018
DOIs
StatePublished - Jan 1 2018

Fingerprint

Cardiopulmonary Resuscitation
Heart Arrest
Pediatrics
Quality Improvement
Technology
Defibrillators
Workflow
Information Systems
Equipment and Supplies

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

Cite this

Design and Deployment of a Pediatric Cardiac Arrest Surveillance System. / Duval-Arnould, Jordan; Newton, Heather Marie; McNamara, Leann; Engorn, Branden Michael; Jones, Kareen; Bernier, Meghan; Dodge, Pamela; Salamone, Cheryl; Bhalala, Utpal; Jeffers, Justin; Engineer, Lilly; Diener-West, Marie; Hunt, Elizabeth.

In: Critical Care Research and Practice, Vol. 2018, 9187962, 01.01.2018.

Research output: Contribution to journalArticle

Duval-Arnould, Jordan ; Newton, Heather Marie ; McNamara, Leann ; Engorn, Branden Michael ; Jones, Kareen ; Bernier, Meghan ; Dodge, Pamela ; Salamone, Cheryl ; Bhalala, Utpal ; Jeffers, Justin ; Engineer, Lilly ; Diener-West, Marie ; Hunt, Elizabeth. / Design and Deployment of a Pediatric Cardiac Arrest Surveillance System. In: Critical Care Research and Practice. 2018 ; Vol. 2018.
@article{5f76634343a14c459f39ea28c71257c3,
title = "Design and Deployment of a Pediatric Cardiac Arrest Surveillance System",
abstract = "Objective. We aimed to increase detection of pediatric cardiopulmonary resuscitation (CPR) events and collection of physiologic and performance data for use in quality improvement (QI) efforts. Materials and Methods. We developed a workflow-driven surveillance system that leveraged organizational information technology systems to trigger CPR detection and analysis processes. We characterized detection by notification source, type, location, and year, and compared it to previous methods of detection. Results. From 1/1/2013 through 12/31/2015, there were 2,986 unique notifications associated with 2,145 events, 317 requiring CPR. PICU and PEDS-ED accounted for 65{\%} of CPR events, whereas floor care areas were responsible for only 3{\%} of events. 100{\%} of PEDS-OR and >70{\%} of PICU CPR events would not have been included in QI efforts. Performance data from both defibrillator and bedside monitor increased annually. (2013: 1{\%}; 2014: 18{\%}; 2015: 27{\%}). Discussion. After deployment of this system, detection has increased ∼9-fold and performance data collection increased annually. Had the system not been deployed, 100{\%} of PEDS-OR and 50-70{\%} of PICU, NICU, and PEDS-ED events would have been missed. Conclusion. By leveraging hospital information technology and medical device data, identification of pediatric cardiac arrest with an associated increased capture in the proportion of objective performance data is possible.",
author = "Jordan Duval-Arnould and Newton, {Heather Marie} and Leann McNamara and Engorn, {Branden Michael} and Kareen Jones and Meghan Bernier and Pamela Dodge and Cheryl Salamone and Utpal Bhalala and Justin Jeffers and Lilly Engineer and Marie Diener-West and Elizabeth Hunt",
year = "2018",
month = "1",
day = "1",
doi = "10.1155/2018/9187962",
language = "English (US)",
volume = "2018",
journal = "Critical Care Research and Practice",
issn = "2090-1305",
publisher = "Hindawi Publishing Corporation",

}

TY - JOUR

T1 - Design and Deployment of a Pediatric Cardiac Arrest Surveillance System

AU - Duval-Arnould, Jordan

AU - Newton, Heather Marie

AU - McNamara, Leann

AU - Engorn, Branden Michael

AU - Jones, Kareen

AU - Bernier, Meghan

AU - Dodge, Pamela

AU - Salamone, Cheryl

AU - Bhalala, Utpal

AU - Jeffers, Justin

AU - Engineer, Lilly

AU - Diener-West, Marie

AU - Hunt, Elizabeth

PY - 2018/1/1

Y1 - 2018/1/1

N2 - Objective. We aimed to increase detection of pediatric cardiopulmonary resuscitation (CPR) events and collection of physiologic and performance data for use in quality improvement (QI) efforts. Materials and Methods. We developed a workflow-driven surveillance system that leveraged organizational information technology systems to trigger CPR detection and analysis processes. We characterized detection by notification source, type, location, and year, and compared it to previous methods of detection. Results. From 1/1/2013 through 12/31/2015, there were 2,986 unique notifications associated with 2,145 events, 317 requiring CPR. PICU and PEDS-ED accounted for 65% of CPR events, whereas floor care areas were responsible for only 3% of events. 100% of PEDS-OR and >70% of PICU CPR events would not have been included in QI efforts. Performance data from both defibrillator and bedside monitor increased annually. (2013: 1%; 2014: 18%; 2015: 27%). Discussion. After deployment of this system, detection has increased ∼9-fold and performance data collection increased annually. Had the system not been deployed, 100% of PEDS-OR and 50-70% of PICU, NICU, and PEDS-ED events would have been missed. Conclusion. By leveraging hospital information technology and medical device data, identification of pediatric cardiac arrest with an associated increased capture in the proportion of objective performance data is possible.

AB - Objective. We aimed to increase detection of pediatric cardiopulmonary resuscitation (CPR) events and collection of physiologic and performance data for use in quality improvement (QI) efforts. Materials and Methods. We developed a workflow-driven surveillance system that leveraged organizational information technology systems to trigger CPR detection and analysis processes. We characterized detection by notification source, type, location, and year, and compared it to previous methods of detection. Results. From 1/1/2013 through 12/31/2015, there were 2,986 unique notifications associated with 2,145 events, 317 requiring CPR. PICU and PEDS-ED accounted for 65% of CPR events, whereas floor care areas were responsible for only 3% of events. 100% of PEDS-OR and >70% of PICU CPR events would not have been included in QI efforts. Performance data from both defibrillator and bedside monitor increased annually. (2013: 1%; 2014: 18%; 2015: 27%). Discussion. After deployment of this system, detection has increased ∼9-fold and performance data collection increased annually. Had the system not been deployed, 100% of PEDS-OR and 50-70% of PICU, NICU, and PEDS-ED events would have been missed. Conclusion. By leveraging hospital information technology and medical device data, identification of pediatric cardiac arrest with an associated increased capture in the proportion of objective performance data is possible.

UR - http://www.scopus.com/inward/record.url?scp=85047569757&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85047569757&partnerID=8YFLogxK

U2 - 10.1155/2018/9187962

DO - 10.1155/2018/9187962

M3 - Article

C2 - 29854451

AN - SCOPUS:85047569757

VL - 2018

JO - Critical Care Research and Practice

JF - Critical Care Research and Practice

SN - 2090-1305

M1 - 9187962

ER -