Construction of 3D MR image-based computer models of pathologic hearts, augmented with histology and optical fluorescence imaging to characterize action potential propagation

Mihaela Pop, Maxime Sermesant, Garry Liu, Jatin Relan, Tommaso Mansi, Alan Soong, Jean Marc Peyrat, Michael V. Truong, Paul Fefer, Elliot R. McVeigh, Herve Delingette, Alexander J. Dick, Nicholas Ayache, Graham A. Wright

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Cardiac computer models can help us understand and predict the propagation of excitation waves (i.e., action potential, AP) in healthy and pathologic hearts. Our broad aim is to develop accurate 3D MR image-based computer models of electrophysiology in large hearts (translatable to clinical applications) and to validate them experimentally. The specific goals of this paper were to match models with maps of the propagation of optical AP on the epicardial surface using large porcine hearts with scars, estimating several parameters relevant to macroscopic reaction-diffusion electrophysiological models. We used voltage-sensitive dyes to image AP in large porcine hearts with scars (three specimens had chronic myocardial infarct, and three had radiofrequency RF acute scars). We first analyzed the main AP waves' characteristics: duration (APD) and propagation under controlled pacing locations and frequencies as recorded from 2D optical images. We further built 3D MR image-based computer models that have information derived from the optical measures, as well as morphologic MRI data (i.e., myocardial anatomy, fiber directions and scar definition). The scar morphology from MR images was validated against corresponding whole-mount histology. We also compared the measured 3D isochronal maps of depolarization to simulated isochrones (the latter replicating precisely the experimental conditions), performing model customization and 3D volumetric adjustments of the local conductivity. Our results demonstrated that mean APD in the border zone (BZ) of the infarct scars was reduced by ~13% (compared to ~318. ms measured in normal zone, NZ), but APD did not change significantly in the thin BZ of the ablation scars. A generic value for velocity ratio (1:2.7) in healthy myocardial tissue was derived from measured values of transverse and longitudinal conduction velocities relative to fibers direction (22. cm/s and 60. cm/s, respectively). The model customization and 3D volumetric adjustment reduced the differences between measurements and simulations; for example, from one pacing location, the adjustment reduced the absolute error in local depolarization times by a factor of 5 (i.e., from 58. ms to 11. ms) in the infarcted heart, and by a factor of 6 (i.e., from 60. ms to 9. ms) in the heart with the RF scar. Moreover, the sensitivity of adjusted conductivity maps to different pacing locations was tested, and the errors in activation times were found to be of approximately 10-12. ms independent of pacing location used to adjust model parameters, suggesting that any location can be used for model predictions.

Original languageEnglish (US)
Pages (from-to)505-523
Number of pages19
JournalMedical Image Analysis
Volume16
Issue number2
DOIs
StatePublished - Feb 2012

Keywords

  • Cardiac computer models
  • Electrophysiology
  • MRI
  • Optical imaging

ASJC Scopus subject areas

  • Computer Graphics and Computer-Aided Design
  • Computer Vision and Pattern Recognition
  • Radiology Nuclear Medicine and imaging
  • Health Informatics
  • Radiological and Ultrasound Technology

Fingerprint

Dive into the research topics of 'Construction of 3D MR image-based computer models of pathologic hearts, augmented with histology and optical fluorescence imaging to characterize action potential propagation'. Together they form a unique fingerprint.

Cite this