T1 - Confirmatory analysis of buprenorphine, norbuprenorphine, and glucuronide metabolites in plasma by LCMSMS. Application to umbilical cord plasma from buprenorphine-maintained pregnant women
AU - Concheiro, Marta
AU - Jones, Hendreé
AU - Johnson, Rolley E.
AU - Shakleya, Diaa M.
AU - Huestis, Marilyn A.
PY - 2009/1/1
Y1 - 2009/1/1
N2 - An LCMSMS method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-glucuronide (BUP-Gluc), and norbuprenorphine-glucuronide (NBUP-Gluc) in 0.5 mL plasma, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. Transitions monitored were 468.3 > 396.2 and 468.3 > 414.3 for BUP, 414.3 > 340.1 and 414.3 > 326.0 for NBUP, 644.3 > 468.1 and 644.3 > 396.3 for BUP-Gluc, and 590.3 > 414.3 and 590.3 > 396.2 for NBUP-Gluc. Linearity was 0.1-50 ng/mL for BUP and BUP-Gluc, and 0.5-50 ng/mL for NBUP and NBUP-Gluc. Intra-day, inter-day, and total assay imprecision (%RSD) were <16.8%, and analytical recoveries were 88.6-108.7%. Extraction efficiencies ranged from 71.1 to 87.1%, and process efficiencies 48.7 to 127.7%. All compounds showed ion enhancement, except BUP-Gluc that demonstrated ion suppression: variation between 10 different blank plasma specimens was <9.1%. In six umbilical cord plasma specimens from opioid-dependent pregnant women receiving 14-24 mg/day BUP, NBUP-Gluc was the predominant metabolite (29.8 ± 7.6 ng/mL), with BUP-Gluc (4.6 ± 4.8 ng/mL), NBUP (1.5 ± 0.8 ng/mL) and BUP (0.4 ± 0.2 ng/mL). Although BUP biomarkers can be quantified in umbilical cord plasma in low ng/mL concentrations, the significance of these data as predictors of neonatal outcomes is currently unknown.
AB - An LCMSMS method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-glucuronide (BUP-Gluc), and norbuprenorphine-glucuronide (NBUP-Gluc) in 0.5 mL plasma, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. Transitions monitored were 468.3 > 396.2 and 468.3 > 414.3 for BUP, 414.3 > 340.1 and 414.3 > 326.0 for NBUP, 644.3 > 468.1 and 644.3 > 396.3 for BUP-Gluc, and 590.3 > 414.3 and 590.3 > 396.2 for NBUP-Gluc. Linearity was 0.1-50 ng/mL for BUP and BUP-Gluc, and 0.5-50 ng/mL for NBUP and NBUP-Gluc. Intra-day, inter-day, and total assay imprecision (%RSD) were <16.8%, and analytical recoveries were 88.6-108.7%. Extraction efficiencies ranged from 71.1 to 87.1%, and process efficiencies 48.7 to 127.7%. All compounds showed ion enhancement, except BUP-Gluc that demonstrated ion suppression: variation between 10 different blank plasma specimens was <9.1%. In six umbilical cord plasma specimens from opioid-dependent pregnant women receiving 14-24 mg/day BUP, NBUP-Gluc was the predominant metabolite (29.8 ± 7.6 ng/mL), with BUP-Gluc (4.6 ± 4.8 ng/mL), NBUP (1.5 ± 0.8 ng/mL) and BUP (0.4 ± 0.2 ng/mL). Although BUP biomarkers can be quantified in umbilical cord plasma in low ng/mL concentrations, the significance of these data as predictors of neonatal outcomes is currently unknown.
KW - Buprenorphine
KW - LCMSMS
KW - Plasma
KW - Umbilical cord plasma
UR - http://www.scopus.com/inward/record.url?scp=71449117665&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=71449117665&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2009.11.005
DO - 10.1016/j.jchromb.2009.11.005
M3 - Article
C2 - 19945361
AN - SCOPUS:71449117665
SN - 1570-0232
VL - 878
SP - 13
EP - 20
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 1
ER -