Compensators for IMRT - An investigation in quality assurance

A. Bakai, Wolfram Laub, F. Nüsslin

Research output: Contribution to journalArticle

Abstract

Intensity modulated radiotherapy (IMRT) allows dose distributions which adequately consider organs at risk (OAR) and dose homogeneity to the target volume. This is practically reached by conforming the beam profiles to the shape of the planning target volume (PTV), by shaping the fluence with multileaf collimators (MLC) or compensators. Though compensator production is time consuming and seems less convenient than the use of MLC, compensators offer much easier quality assurance. In this study the effects of certain simplifications of compensator production were studied. Compensators were produced and ionization chamber measurements in a water phantom and film measurements in a solid phantom were performed to verify the compensators. The results of the measurements were compared to the fluence distributions given by the planning system. The measurements were meant to show how realistic the investigated simplifications were, and to reveal a suitable and reliable testing method for compensators. Monte-Carlo calculations employing the EGS 4 Code were further performed to support the measurements.

Original languageEnglish (US)
Pages (from-to)15-22
Number of pages8
JournalZeitschrift fur Medizinische Physik
Volume11
Issue number1
StatePublished - Jan 1 2001
Externally publishedYes

Fingerprint

Organs at Risk
Intensity-Modulated Radiotherapy
Water

Keywords

  • Compensators
  • IMRT
  • Quality assurance

ASJC Scopus subject areas

  • Biophysics
  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

Compensators for IMRT - An investigation in quality assurance. / Bakai, A.; Laub, Wolfram; Nüsslin, F.

In: Zeitschrift fur Medizinische Physik, Vol. 11, No. 1, 01.01.2001, p. 15-22.

Research output: Contribution to journalArticle

@article{293e3ac773a94a0f89beaf450cc6dae7,
title = "Compensators for IMRT - An investigation in quality assurance",
abstract = "Intensity modulated radiotherapy (IMRT) allows dose distributions which adequately consider organs at risk (OAR) and dose homogeneity to the target volume. This is practically reached by conforming the beam profiles to the shape of the planning target volume (PTV), by shaping the fluence with multileaf collimators (MLC) or compensators. Though compensator production is time consuming and seems less convenient than the use of MLC, compensators offer much easier quality assurance. In this study the effects of certain simplifications of compensator production were studied. Compensators were produced and ionization chamber measurements in a water phantom and film measurements in a solid phantom were performed to verify the compensators. The results of the measurements were compared to the fluence distributions given by the planning system. The measurements were meant to show how realistic the investigated simplifications were, and to reveal a suitable and reliable testing method for compensators. Monte-Carlo calculations employing the EGS 4 Code were further performed to support the measurements.",
keywords = "Compensators, IMRT, Quality assurance",
author = "A. Bakai and Wolfram Laub and F. N{\"u}sslin",
year = "2001",
month = "1",
day = "1",
language = "English (US)",
volume = "11",
pages = "15--22",
journal = "Zeitschrift fur Medizinische Physik",
issn = "0939-3889",
publisher = "Urban und Fischer Verlag Jena",
number = "1",

}

TY - JOUR

T1 - Compensators for IMRT - An investigation in quality assurance

AU - Bakai, A.

AU - Laub, Wolfram

AU - Nüsslin, F.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - Intensity modulated radiotherapy (IMRT) allows dose distributions which adequately consider organs at risk (OAR) and dose homogeneity to the target volume. This is practically reached by conforming the beam profiles to the shape of the planning target volume (PTV), by shaping the fluence with multileaf collimators (MLC) or compensators. Though compensator production is time consuming and seems less convenient than the use of MLC, compensators offer much easier quality assurance. In this study the effects of certain simplifications of compensator production were studied. Compensators were produced and ionization chamber measurements in a water phantom and film measurements in a solid phantom were performed to verify the compensators. The results of the measurements were compared to the fluence distributions given by the planning system. The measurements were meant to show how realistic the investigated simplifications were, and to reveal a suitable and reliable testing method for compensators. Monte-Carlo calculations employing the EGS 4 Code were further performed to support the measurements.

AB - Intensity modulated radiotherapy (IMRT) allows dose distributions which adequately consider organs at risk (OAR) and dose homogeneity to the target volume. This is practically reached by conforming the beam profiles to the shape of the planning target volume (PTV), by shaping the fluence with multileaf collimators (MLC) or compensators. Though compensator production is time consuming and seems less convenient than the use of MLC, compensators offer much easier quality assurance. In this study the effects of certain simplifications of compensator production were studied. Compensators were produced and ionization chamber measurements in a water phantom and film measurements in a solid phantom were performed to verify the compensators. The results of the measurements were compared to the fluence distributions given by the planning system. The measurements were meant to show how realistic the investigated simplifications were, and to reveal a suitable and reliable testing method for compensators. Monte-Carlo calculations employing the EGS 4 Code were further performed to support the measurements.

KW - Compensators

KW - IMRT

KW - Quality assurance

UR - http://www.scopus.com/inward/record.url?scp=0035067023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035067023&partnerID=8YFLogxK

M3 - Article

C2 - 11487855

AN - SCOPUS:0035067023

VL - 11

SP - 15

EP - 22

JO - Zeitschrift fur Medizinische Physik

JF - Zeitschrift fur Medizinische Physik

SN - 0939-3889

IS - 1

ER -