Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi

Translated title of the contribution: Comparison of three different mycobacterial DNA isolation methods

Alpaslan Alp, Şehnaz Alp, Zeynep Saribaş, Gülşen Hasçelik

Research output: Contribution to journalArticle

Abstract

Rapid diagnosis of mycobacterial infections is of crucial importance. For this reason molecular methods have become valuable diagnostic tools. DNA isolation step prior to polymerase chain reaction (PCR) is one of the most important steps that affect the sensitivity of the diagnostic tests. In this study, three isolation methods which could affect the sensitivity of the PCR methods used for the diagnosis of mycobacterial infections were compared. For this reason the sensitivities of boiling method, MagNA Pure LC automated isolation system (Roche Applied Science, Germany) and Magtration 12GC (Precision System Science, Germany) automated isolation system were compared by using four different mycobacterial strains (Mycobacterium tuberculosis H37Ra standard strain, M.tuberculosis clinical isolate, M.phlei and M.smegmatis). DNAs were isolated from serial dilutions of these mycobacterial strains by using three isolation methods, and 441 base pair region of hsp65 gene was amplified by PCR. After the obtained products were run on agarose gel, it was observed that the lowest dilution rates at which bands could be seen were 10-5 dilutions of H37Ra DNA isolated by MagNA Pure and Magtration systems. Isolation of H37Ra DNA by boiling method yielded a band in 10-2 dilution sample. Isolation of DNA from Mycobacterium tuberculosis clinical isolate by MagNA Pure system, Magtration system and boiling method provided amplification in 10-4, 10-3 and 10-1 dilution samples, respectively. The lowest dilution samples which yielded visible bands on agarose gel were 10-5, 10-4 and 10-2 dilution samples for M.smegmatis strain and 10-4, 10-3 and 10-2 dilution samples for M.phlei strain. The results of this study revealed that MagNA Pure system could detect smaller amounts of DNA in the sample while boiling method was not a reliable method to detect small amounts of DNA in clinical samples. Therefore it was concluded that the use of automated isolation systems could be a reliable alternative for routine PCR applications by providing both high sensitivity and standardization.

Original languageTurkish
Pages (from-to)395-402
Number of pages8
JournalMikrobiyoloji Bulteni
Volume41
Issue number3
StatePublished - Apr 2007
Externally publishedYes

Fingerprint

DNA
Smegma
Polymerase Chain Reaction
Mycobacterium tuberculosis
Sepharose
Germany
Gels
Infection
Routine Diagnostic Tests
Base Pairing
Tuberculosis
Genes

Keywords

  • DNA isolation methods
  • MagNA Pure LC
  • Magtration 12GC
  • Mycobacteria

ASJC Scopus subject areas

  • Infectious Diseases
  • Microbiology (medical)
  • Immunology and Microbiology(all)

Cite this

Alp, A., Alp, Ş., Saribaş, Z., & Hasçelik, G. (2007). Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi. Mikrobiyoloji Bulteni, 41(3), 395-402.

Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi. / Alp, Alpaslan; Alp, Şehnaz; Saribaş, Zeynep; Hasçelik, Gülşen.

In: Mikrobiyoloji Bulteni, Vol. 41, No. 3, 04.2007, p. 395-402.

Research output: Contribution to journalArticle

Alp, A, Alp, Ş, Saribaş, Z & Hasçelik, G 2007, 'Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi', Mikrobiyoloji Bulteni, vol. 41, no. 3, pp. 395-402.
Alp, Alpaslan ; Alp, Şehnaz ; Saribaş, Zeynep ; Hasçelik, Gülşen. / Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi. In: Mikrobiyoloji Bulteni. 2007 ; Vol. 41, No. 3. pp. 395-402.
@article{7fbaa978b3e64444b1b558514fdfee0b,
title = "Mi̇kobakteri̇yel DNA i̇zolasyonunda {\"u}{\cc} farkli y{\"o}ntemi̇ni̇n karşilaştirilmasi",
abstract = "Rapid diagnosis of mycobacterial infections is of crucial importance. For this reason molecular methods have become valuable diagnostic tools. DNA isolation step prior to polymerase chain reaction (PCR) is one of the most important steps that affect the sensitivity of the diagnostic tests. In this study, three isolation methods which could affect the sensitivity of the PCR methods used for the diagnosis of mycobacterial infections were compared. For this reason the sensitivities of boiling method, MagNA Pure LC automated isolation system (Roche Applied Science, Germany) and Magtration 12GC (Precision System Science, Germany) automated isolation system were compared by using four different mycobacterial strains (Mycobacterium tuberculosis H37Ra standard strain, M.tuberculosis clinical isolate, M.phlei and M.smegmatis). DNAs were isolated from serial dilutions of these mycobacterial strains by using three isolation methods, and 441 base pair region of hsp65 gene was amplified by PCR. After the obtained products were run on agarose gel, it was observed that the lowest dilution rates at which bands could be seen were 10-5 dilutions of H37Ra DNA isolated by MagNA Pure and Magtration systems. Isolation of H37Ra DNA by boiling method yielded a band in 10-2 dilution sample. Isolation of DNA from Mycobacterium tuberculosis clinical isolate by MagNA Pure system, Magtration system and boiling method provided amplification in 10-4, 10-3 and 10-1 dilution samples, respectively. The lowest dilution samples which yielded visible bands on agarose gel were 10-5, 10-4 and 10-2 dilution samples for M.smegmatis strain and 10-4, 10-3 and 10-2 dilution samples for M.phlei strain. The results of this study revealed that MagNA Pure system could detect smaller amounts of DNA in the sample while boiling method was not a reliable method to detect small amounts of DNA in clinical samples. Therefore it was concluded that the use of automated isolation systems could be a reliable alternative for routine PCR applications by providing both high sensitivity and standardization.",
keywords = "DNA isolation methods, MagNA Pure LC, Magtration 12GC, Mycobacteria",
author = "Alpaslan Alp and Şehnaz Alp and Zeynep Saribaş and G{\"u}lşen Has{\cc}elik",
year = "2007",
month = "4",
language = "Turkish",
volume = "41",
pages = "395--402",
journal = "Mikrobiyoloji Bulteni",
issn = "0374-9096",
publisher = "Ankara Microbiology Society",
number = "3",

}

TY - JOUR

T1 - Mi̇kobakteri̇yel DNA i̇zolasyonunda üç farkli yöntemi̇ni̇n karşilaştirilmasi

AU - Alp, Alpaslan

AU - Alp, Şehnaz

AU - Saribaş, Zeynep

AU - Hasçelik, Gülşen

PY - 2007/4

Y1 - 2007/4

N2 - Rapid diagnosis of mycobacterial infections is of crucial importance. For this reason molecular methods have become valuable diagnostic tools. DNA isolation step prior to polymerase chain reaction (PCR) is one of the most important steps that affect the sensitivity of the diagnostic tests. In this study, three isolation methods which could affect the sensitivity of the PCR methods used for the diagnosis of mycobacterial infections were compared. For this reason the sensitivities of boiling method, MagNA Pure LC automated isolation system (Roche Applied Science, Germany) and Magtration 12GC (Precision System Science, Germany) automated isolation system were compared by using four different mycobacterial strains (Mycobacterium tuberculosis H37Ra standard strain, M.tuberculosis clinical isolate, M.phlei and M.smegmatis). DNAs were isolated from serial dilutions of these mycobacterial strains by using three isolation methods, and 441 base pair region of hsp65 gene was amplified by PCR. After the obtained products were run on agarose gel, it was observed that the lowest dilution rates at which bands could be seen were 10-5 dilutions of H37Ra DNA isolated by MagNA Pure and Magtration systems. Isolation of H37Ra DNA by boiling method yielded a band in 10-2 dilution sample. Isolation of DNA from Mycobacterium tuberculosis clinical isolate by MagNA Pure system, Magtration system and boiling method provided amplification in 10-4, 10-3 and 10-1 dilution samples, respectively. The lowest dilution samples which yielded visible bands on agarose gel were 10-5, 10-4 and 10-2 dilution samples for M.smegmatis strain and 10-4, 10-3 and 10-2 dilution samples for M.phlei strain. The results of this study revealed that MagNA Pure system could detect smaller amounts of DNA in the sample while boiling method was not a reliable method to detect small amounts of DNA in clinical samples. Therefore it was concluded that the use of automated isolation systems could be a reliable alternative for routine PCR applications by providing both high sensitivity and standardization.

AB - Rapid diagnosis of mycobacterial infections is of crucial importance. For this reason molecular methods have become valuable diagnostic tools. DNA isolation step prior to polymerase chain reaction (PCR) is one of the most important steps that affect the sensitivity of the diagnostic tests. In this study, three isolation methods which could affect the sensitivity of the PCR methods used for the diagnosis of mycobacterial infections were compared. For this reason the sensitivities of boiling method, MagNA Pure LC automated isolation system (Roche Applied Science, Germany) and Magtration 12GC (Precision System Science, Germany) automated isolation system were compared by using four different mycobacterial strains (Mycobacterium tuberculosis H37Ra standard strain, M.tuberculosis clinical isolate, M.phlei and M.smegmatis). DNAs were isolated from serial dilutions of these mycobacterial strains by using three isolation methods, and 441 base pair region of hsp65 gene was amplified by PCR. After the obtained products were run on agarose gel, it was observed that the lowest dilution rates at which bands could be seen were 10-5 dilutions of H37Ra DNA isolated by MagNA Pure and Magtration systems. Isolation of H37Ra DNA by boiling method yielded a band in 10-2 dilution sample. Isolation of DNA from Mycobacterium tuberculosis clinical isolate by MagNA Pure system, Magtration system and boiling method provided amplification in 10-4, 10-3 and 10-1 dilution samples, respectively. The lowest dilution samples which yielded visible bands on agarose gel were 10-5, 10-4 and 10-2 dilution samples for M.smegmatis strain and 10-4, 10-3 and 10-2 dilution samples for M.phlei strain. The results of this study revealed that MagNA Pure system could detect smaller amounts of DNA in the sample while boiling method was not a reliable method to detect small amounts of DNA in clinical samples. Therefore it was concluded that the use of automated isolation systems could be a reliable alternative for routine PCR applications by providing both high sensitivity and standardization.

KW - DNA isolation methods

KW - MagNA Pure LC

KW - Magtration 12GC

KW - Mycobacteria

UR - http://www.scopus.com/inward/record.url?scp=42149176704&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=42149176704&partnerID=8YFLogxK

M3 - Article

VL - 41

SP - 395

EP - 402

JO - Mikrobiyoloji Bulteni

JF - Mikrobiyoloji Bulteni

SN - 0374-9096

IS - 3

ER -