Abstract
A study of the Kleihauer-Betke acid-elution technique for quantitating fetomaternal hemorrhage was performed to assess intra- and inter-technologist accuracy and precision as well as to delineate the statistically valid domain of the test as usually performed. The results were then compared to a parallel study quantitating fetomaternal hemorrhage by flow cytometry. Additionally, a statistical model for estimating efficacy of treatment with Rh immune globulin in the prevention of pregnancy-associated Rh(D) isoimmunization was developed. The results indicate that the acid-elution technique can be performed in a reproducible manner with acceptable accuracy and precision with whole blood fetomaternal hemorrhages 25 ml and higher if a background correction for false positive identification of fetal cells is included. Flow cytometric determination reveals significantly increased accuracy in comparison to the corresponding Kleihauer-Betke results.
Original language | English (US) |
---|---|
Pages (from-to) | 197-206 |
Number of pages | 10 |
Journal | Annals of Clinical and Laboratory Science |
Volume | 17 |
Issue number | 3 |
State | Published - 1987 |
Externally published | Yes |
ASJC Scopus subject areas
- Microbiology
- Immunology and Allergy
- Pathology and Forensic Medicine
- Immunology
- Molecular Biology
- Hematology
- Clinical Biochemistry
- Medical Laboratory Technology