Comparison of 180° and 360° acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and mathematical observer results

Research output: Contribution to journalArticle

Abstract

Background: The optimal projection data acquisition strategy for myocardial perfusion (MP) single photon emission computed tomography (SPECT) remains controversial. Methods: We compared MP SPECT using 180° and 360° projection data obtained with the same acquisition time, reconstructed either with filtered back projection (FBP) or the iterative ordered-subsets expectation maximization (OS-EM) algorithm with various combinations of attenuation, detector response, and scatter compensation using mathematical observers and a myocardial defect detection task. We used Monte Carlo-simulated projection data from a population of 3-dimensional nurbs-based cardiac-torso (NCAT) phantoms with ranges of variability in patient anatomy, organ uptake, defect location, defect size, and noise level based on clinical data. Projection data from 180° and 360° acquisitions were generated by assuming the same acquisition time. After iterative or FBP reconstruction, standard postprocessing methods were applied. For each acquisition and reconstruction method, we optimized the number of iterations and cut-off frequency of the Butterworth filter using the Channelized Hotelling Observer methodology. The optimum set of parameters was that which gave the maximum area under the curve. Results: For both acquisition protocols, OS-EM with compensations provided better performance than FBP or OS-EM without compensation. For FBP, the optimized 180° acquisition provided a statistically significant increase in AUC as compared with optimized 360° acquisition. For OS-EM, the AUCs for 180° were slightly larger than for 360° acquisitions when comparing images reconstructed with the same compensations. However, the differences were smaller and not statistically significant. Conclusion: With optimized reconstruction and filtering parameters, 180° acquisition provided a statistically significant improvement over 360° acquisition for FBP reconstruction. However, for OS-EM the differences were small and not statistically significant.

Original languageEnglish (US)
Pages (from-to)345-353
Number of pages9
JournalJournal of Nuclear Cardiology
Volume13
Issue number3
DOIs
StatePublished - Jun 1 2006

Keywords

  • Myocardial perfusion imaging protocol
  • SPECT acquisition
  • observer study
  • receiver operating characteristic

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint Dive into the research topics of 'Comparison of 180° and 360° acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and mathematical observer results'. Together they form a unique fingerprint.

  • Cite this