TY - JOUR
T1 - Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination
AU - Dubin, Jonathan
AU - Wallerson, Donald C.
AU - Cody, Robert J.
AU - Devereux, Richard B.
PY - 1990/7
Y1 - 1990/7
N2 - Numerous Doppler echocardiographic methods to measure stroke volume have been proposed in experimental or clinical studies, but their relative accuracy in patients compared with an invasive reference standard remains uncertain. Accordingly, we compared Doppler with thermodilution stroke volume measurement in 18 hospitalized patients, 16 with an acute manifestation of coronary artery disease and two with chronic cardiomyopathies. Doppler time-velocity integrals were measured by darkest line (modal velocity) and the leading edge (maximal velocity) techniques at the aortic annular plane, the mitral orifice, and the mitral annular plane. Two-dimensional echocardiography was used to measure cross-sectional areas (M-mode-corrected at the mitral orifice). The combination of aortic annular cross-sectional area and the leading edge technique of measuring the time-velocity integral of blood flow at this site provided the most accurate measure of stroke volume (r = 0.87, p < 0.0001, standard error of estimate = 11 cm3; mean difference from thermodilution = 2.8 ml ± 8.9 ml, p = NS). It also resulted in the most accurate measurement of cardiac output (r = 0.88, p < 0.0003; mean difference from thermodilution = 0.11 L/min ± 0.69 L/min, p = NS). Other methods yielded values that correlated less closely and deviated systematically from thermodilution measurements. We therefore conclude that of the six common methods evaluated, the aortic annular leading edge method measures stroke volume with the best accuracy and is most suitable for clinical application.
AB - Numerous Doppler echocardiographic methods to measure stroke volume have been proposed in experimental or clinical studies, but their relative accuracy in patients compared with an invasive reference standard remains uncertain. Accordingly, we compared Doppler with thermodilution stroke volume measurement in 18 hospitalized patients, 16 with an acute manifestation of coronary artery disease and two with chronic cardiomyopathies. Doppler time-velocity integrals were measured by darkest line (modal velocity) and the leading edge (maximal velocity) techniques at the aortic annular plane, the mitral orifice, and the mitral annular plane. Two-dimensional echocardiography was used to measure cross-sectional areas (M-mode-corrected at the mitral orifice). The combination of aortic annular cross-sectional area and the leading edge technique of measuring the time-velocity integral of blood flow at this site provided the most accurate measure of stroke volume (r = 0.87, p < 0.0001, standard error of estimate = 11 cm3; mean difference from thermodilution = 2.8 ml ± 8.9 ml, p = NS). It also resulted in the most accurate measurement of cardiac output (r = 0.88, p < 0.0003; mean difference from thermodilution = 0.11 L/min ± 0.69 L/min, p = NS). Other methods yielded values that correlated less closely and deviated systematically from thermodilution measurements. We therefore conclude that of the six common methods evaluated, the aortic annular leading edge method measures stroke volume with the best accuracy and is most suitable for clinical application.
UR - http://www.scopus.com/inward/record.url?scp=0025291657&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025291657&partnerID=8YFLogxK
U2 - 10.1016/0002-8703(90)90168-W
DO - 10.1016/0002-8703(90)90168-W
M3 - Article
C2 - 2360495
AN - SCOPUS:0025291657
SN - 0002-8703
VL - 120
SP - 116
EP - 123
JO - American heart journal
JF - American heart journal
IS - 1