Combined T2-preparation and two-dimensional pencil-beam inner volume selection

Andrew J. Coristine, Ruud B. Van Heeswijk, Matthias Stuber

Research output: Contribution to journalArticle

Abstract

Purpose To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2-preparation module ("2D-T2-Prep"). Methods An adiabatic T2-Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2-prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2-prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. Results In vivo, full field-of-view 2D-T2-Prep significantly improved vessel sharpness as compared to conventional T2-Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. Conclusion When compared with conventional T2-Prep, the 2D-T2-Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition. Magn Reson Med 74:529-536, 2015.

Original languageEnglish (US)
Pages (from-to)529-536
Number of pages8
JournalMagnetic Resonance in Medicine
Volume74
Issue number2
DOIs
StatePublished - Aug 1 2015
Externally publishedYes

Fingerprint

Noise
Magnetic Resonance Angiography
Coronary Angiography
Artifacts
Pulse

Keywords

  • 2D
  • adiabatic
  • coronary
  • inner volume
  • T<inf>2</inf>-prep

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Combined T2-preparation and two-dimensional pencil-beam inner volume selection. / Coristine, Andrew J.; Van Heeswijk, Ruud B.; Stuber, Matthias.

In: Magnetic Resonance in Medicine, Vol. 74, No. 2, 01.08.2015, p. 529-536.

Research output: Contribution to journalArticle

Coristine, Andrew J. ; Van Heeswijk, Ruud B. ; Stuber, Matthias. / Combined T2-preparation and two-dimensional pencil-beam inner volume selection. In: Magnetic Resonance in Medicine. 2015 ; Vol. 74, No. 2. pp. 529-536.
@article{6d20383d17cc40e2b98e857cdf273c12,
title = "Combined T2-preparation and two-dimensional pencil-beam inner volume selection",
abstract = "Purpose To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2-preparation module ({"}2D-T2-Prep{"}). Methods An adiabatic T2-Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2-prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2-prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. Results In vivo, full field-of-view 2D-T2-Prep significantly improved vessel sharpness as compared to conventional T2-Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60{\%}. Conclusion When compared with conventional T2-Prep, the 2D-T2-Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition. Magn Reson Med 74:529-536, 2015.",
keywords = "2D, adiabatic, coronary, inner volume, T<inf>2</inf>-prep",
author = "Coristine, {Andrew J.} and {Van Heeswijk}, {Ruud B.} and Matthias Stuber",
year = "2015",
month = "8",
day = "1",
doi = "10.1002/mrm.25442",
language = "English (US)",
volume = "74",
pages = "529--536",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Combined T2-preparation and two-dimensional pencil-beam inner volume selection

AU - Coristine, Andrew J.

AU - Van Heeswijk, Ruud B.

AU - Stuber, Matthias

PY - 2015/8/1

Y1 - 2015/8/1

N2 - Purpose To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2-preparation module ("2D-T2-Prep"). Methods An adiabatic T2-Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2-prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2-prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. Results In vivo, full field-of-view 2D-T2-Prep significantly improved vessel sharpness as compared to conventional T2-Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. Conclusion When compared with conventional T2-Prep, the 2D-T2-Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition. Magn Reson Med 74:529-536, 2015.

AB - Purpose To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2-preparation module ("2D-T2-Prep"). Methods An adiabatic T2-Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2-prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2-prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. Results In vivo, full field-of-view 2D-T2-Prep significantly improved vessel sharpness as compared to conventional T2-Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. Conclusion When compared with conventional T2-Prep, the 2D-T2-Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition. Magn Reson Med 74:529-536, 2015.

KW - 2D

KW - adiabatic

KW - coronary

KW - inner volume

KW - T<inf>2</inf>-prep

UR - http://www.scopus.com/inward/record.url?scp=84937720053&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937720053&partnerID=8YFLogxK

U2 - 10.1002/mrm.25442

DO - 10.1002/mrm.25442

M3 - Article

C2 - 25163988

AN - SCOPUS:84937720053

VL - 74

SP - 529

EP - 536

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -