Cardiovascular magnetic resonance (CMR) imaging has evolved rapidly and is now accepted as a powerful diagnostic tool with significant clinical and research applications. Clinical 3 Tesla (3 T) scanners are increasingly available and offer improved diagnostic capabilities compared to 1.5 T scanners for perfusion, viability, and coronary imaging. Although technical challenges remain for cardiac imaging at higher field strengths such as balanced steady state free precession (bSSFP) cine imaging, the majority of cardiac applications are feasible at 3 T with comparable or superior image quality to that of 1.5 T. This review will focus on the benefits and limitations of 3 T CMR for common clinical applications and examine areas in development for potential clinical use.

Original languageEnglish (US)
Pages (from-to)237-242
Number of pages6
JournalCurrent Cardiology Reviews
Volume5
Issue number3
DOIs
StatePublished - Aug 2009

Fingerprint

Magnetic Resonance Spectroscopy
Perfusion
Magnetic Resonance Imaging
Research

Keywords

  • 3 Tesla
  • Cardiac magnetic resonance

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Clinical applications for cardiovascular magnetic resonance imaging at 3 Tesla. / Hays, Allison; Schar, Michael; Kelle, Sebastian.

In: Current Cardiology Reviews, Vol. 5, No. 3, 08.2009, p. 237-242.

Research output: Contribution to journalArticle

@article{1cc83a0b96c44fd6b929a7829d2f81a7,
title = "Clinical applications for cardiovascular magnetic resonance imaging at 3 Tesla",
abstract = "Cardiovascular magnetic resonance (CMR) imaging has evolved rapidly and is now accepted as a powerful diagnostic tool with significant clinical and research applications. Clinical 3 Tesla (3 T) scanners are increasingly available and offer improved diagnostic capabilities compared to 1.5 T scanners for perfusion, viability, and coronary imaging. Although technical challenges remain for cardiac imaging at higher field strengths such as balanced steady state free precession (bSSFP) cine imaging, the majority of cardiac applications are feasible at 3 T with comparable or superior image quality to that of 1.5 T. This review will focus on the benefits and limitations of 3 T CMR for common clinical applications and examine areas in development for potential clinical use.",
keywords = "3 Tesla, Cardiac magnetic resonance",
author = "Allison Hays and Michael Schar and Sebastian Kelle",
year = "2009",
month = "8",
doi = "10.2174/157340309788970351",
language = "English (US)",
volume = "5",
pages = "237--242",
journal = "Current Cardiology Reviews",
issn = "1573-403X",
publisher = "Bentham Science Publishers B.V.",
number = "3",

}

TY - JOUR

T1 - Clinical applications for cardiovascular magnetic resonance imaging at 3 Tesla

AU - Hays, Allison

AU - Schar, Michael

AU - Kelle, Sebastian

PY - 2009/8

Y1 - 2009/8

N2 - Cardiovascular magnetic resonance (CMR) imaging has evolved rapidly and is now accepted as a powerful diagnostic tool with significant clinical and research applications. Clinical 3 Tesla (3 T) scanners are increasingly available and offer improved diagnostic capabilities compared to 1.5 T scanners for perfusion, viability, and coronary imaging. Although technical challenges remain for cardiac imaging at higher field strengths such as balanced steady state free precession (bSSFP) cine imaging, the majority of cardiac applications are feasible at 3 T with comparable or superior image quality to that of 1.5 T. This review will focus on the benefits and limitations of 3 T CMR for common clinical applications and examine areas in development for potential clinical use.

AB - Cardiovascular magnetic resonance (CMR) imaging has evolved rapidly and is now accepted as a powerful diagnostic tool with significant clinical and research applications. Clinical 3 Tesla (3 T) scanners are increasingly available and offer improved diagnostic capabilities compared to 1.5 T scanners for perfusion, viability, and coronary imaging. Although technical challenges remain for cardiac imaging at higher field strengths such as balanced steady state free precession (bSSFP) cine imaging, the majority of cardiac applications are feasible at 3 T with comparable or superior image quality to that of 1.5 T. This review will focus on the benefits and limitations of 3 T CMR for common clinical applications and examine areas in development for potential clinical use.

KW - 3 Tesla

KW - Cardiac magnetic resonance

UR - http://www.scopus.com/inward/record.url?scp=70449717526&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449717526&partnerID=8YFLogxK

U2 - 10.2174/157340309788970351

DO - 10.2174/157340309788970351

M3 - Article

C2 - 20676283

AN - SCOPUS:70449717526

VL - 5

SP - 237

EP - 242

JO - Current Cardiology Reviews

JF - Current Cardiology Reviews

SN - 1573-403X

IS - 3

ER -