Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose

Ruediger E. Schernthaner, Reham R. Haroun, Sonny Nguyen, Rafael Duran, Jae Ho Sohn, Sonia Sahu, Julius Chapiro, Yan Zhao, Alessandro Radaelli, Imramsjah M. van der Bom, Maria Mauti, Kelvin Hong, Jean François H. Geschwind, Ming De Lin

Research output: Contribution to journalArticle

Abstract

Purpose: To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). Materials and Methods: In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. Results: There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). Conclusions: The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

Original languageEnglish (US)
Pages (from-to)1-7
Number of pages7
JournalCardioVascular and Interventional Radiology
DOIs
StateAccepted/In press - Oct 31 2017

Fingerprint

Digital Subtraction Angiography
Fluoroscopy
Uterine Artery Embolization
X-Rays
Radiation
Nonparametric Statistics
Air
Research Ethics Committees
Leiomyoma
Body Mass Index

Keywords

  • Image quality enhancement
  • Interventional radiology
  • Radiation dosage

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Cite this

Characteristics of a New X-Ray Imaging System for Interventional Procedures : Improved Image Quality and Reduced Radiation Dose. / Schernthaner, Ruediger E.; Haroun, Reham R.; Nguyen, Sonny; Duran, Rafael; Sohn, Jae Ho; Sahu, Sonia; Chapiro, Julius; Zhao, Yan; Radaelli, Alessandro; van der Bom, Imramsjah M.; Mauti, Maria; Hong, Kelvin; Geschwind, Jean François H.; Lin, Ming De.

In: CardioVascular and Interventional Radiology, 31.10.2017, p. 1-7.

Research output: Contribution to journalArticle

Schernthaner, RE, Haroun, RR, Nguyen, S, Duran, R, Sohn, JH, Sahu, S, Chapiro, J, Zhao, Y, Radaelli, A, van der Bom, IM, Mauti, M, Hong, K, Geschwind, JFH & Lin, MD 2017, 'Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose', CardioVascular and Interventional Radiology, pp. 1-7. https://doi.org/10.1007/s00270-017-1821-z
Schernthaner, Ruediger E. ; Haroun, Reham R. ; Nguyen, Sonny ; Duran, Rafael ; Sohn, Jae Ho ; Sahu, Sonia ; Chapiro, Julius ; Zhao, Yan ; Radaelli, Alessandro ; van der Bom, Imramsjah M. ; Mauti, Maria ; Hong, Kelvin ; Geschwind, Jean François H. ; Lin, Ming De. / Characteristics of a New X-Ray Imaging System for Interventional Procedures : Improved Image Quality and Reduced Radiation Dose. In: CardioVascular and Interventional Radiology. 2017 ; pp. 1-7.
@article{09d3cbdc0fff4caeafc7af1cf59fbbb2,
title = "Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose",
abstract = "Purpose: To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). Materials and Methods: In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. Results: There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72{\%}, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59{\%} (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78{\%} (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). Conclusions: The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.",
keywords = "Image quality enhancement, Interventional radiology, Radiation dosage",
author = "Schernthaner, {Ruediger E.} and Haroun, {Reham R.} and Sonny Nguyen and Rafael Duran and Sohn, {Jae Ho} and Sonia Sahu and Julius Chapiro and Yan Zhao and Alessandro Radaelli and {van der Bom}, {Imramsjah M.} and Maria Mauti and Kelvin Hong and Geschwind, {Jean Fran{\cc}ois H.} and Lin, {Ming De}",
year = "2017",
month = "10",
day = "31",
doi = "10.1007/s00270-017-1821-z",
language = "English (US)",
pages = "1--7",
journal = "CardioVascular and Interventional Radiology",
issn = "7415-5101",
publisher = "Springer Verlag",

}

TY - JOUR

T1 - Characteristics of a New X-Ray Imaging System for Interventional Procedures

T2 - Improved Image Quality and Reduced Radiation Dose

AU - Schernthaner, Ruediger E.

AU - Haroun, Reham R.

AU - Nguyen, Sonny

AU - Duran, Rafael

AU - Sohn, Jae Ho

AU - Sahu, Sonia

AU - Chapiro, Julius

AU - Zhao, Yan

AU - Radaelli, Alessandro

AU - van der Bom, Imramsjah M.

AU - Mauti, Maria

AU - Hong, Kelvin

AU - Geschwind, Jean François H.

AU - Lin, Ming De

PY - 2017/10/31

Y1 - 2017/10/31

N2 - Purpose: To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). Materials and Methods: In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. Results: There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). Conclusions: The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

AB - Purpose: To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). Materials and Methods: In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. Results: There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm2 vs. 1.62 Gy and 526.8 Gy*cm2, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm2, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm2, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). Conclusions: The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

KW - Image quality enhancement

KW - Interventional radiology

KW - Radiation dosage

UR - http://www.scopus.com/inward/record.url?scp=85032691971&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85032691971&partnerID=8YFLogxK

U2 - 10.1007/s00270-017-1821-z

DO - 10.1007/s00270-017-1821-z

M3 - Article

C2 - 29090348

AN - SCOPUS:85032691971

SP - 1

EP - 7

JO - CardioVascular and Interventional Radiology

JF - CardioVascular and Interventional Radiology

SN - 7415-5101

ER -