N2 - Recent improvements in intravascular magnetic resonance imaging techniques mandate an accurate method of monitoring the introduction of MR catheter probes into the vessel of interest. For this purpose, a novel imaging protocol and a display method have been designed. First, a roadmap 3D image data set with standard pulse sequences is obtained using an external imaging coil. Subsequently, using very narrow rectangular-FOV fast-spoiled gradient recalled (SPGR), a movie of the percutaneous placement procedure of an MR catheter probe is acquired at a rate of 7.3 frames/second. In this protocol, the probe is used to transmit RF pulses and receive MR signal. A computer program was written for image unwrapping and for displaying the unwrapped movie frames on the roadmap image. In an alternative protocol, the movie frames in two projection angles were acquired in an interleaved fashion. Frames were unwrapped and combined with a 3D roadmap and displayed on a Silicon Graphics workstation equipped with stereovision goggles. Using these methods, percutaneous catheter placement in a phantom and a dog was examined. In conclusion, a new visualization technique for MR catheter placement is proposed. Combining this technique with high resolution intravascular MRI techniques may result in a very useful diagnostic tool for the evaluation of atherosclerosis and other vessel diseases.
AB - Recent improvements in intravascular magnetic resonance imaging techniques mandate an accurate method of monitoring the introduction of MR catheter probes into the vessel of interest. For this purpose, a novel imaging protocol and a display method have been designed. First, a roadmap 3D image data set with standard pulse sequences is obtained using an external imaging coil. Subsequently, using very narrow rectangular-FOV fast-spoiled gradient recalled (SPGR), a movie of the percutaneous placement procedure of an MR catheter probe is acquired at a rate of 7.3 frames/second. In this protocol, the probe is used to transmit RF pulses and receive MR signal. A computer program was written for image unwrapping and for displaying the unwrapped movie frames on the roadmap image. In an alternative protocol, the movie frames in two projection angles were acquired in an interleaved fashion. Frames were unwrapped and combined with a 3D roadmap and displayed on a Silicon Graphics workstation equipped with stereovision goggles. Using these methods, percutaneous catheter placement in a phantom and a dog was examined. In conclusion, a new visualization technique for MR catheter placement is proposed. Combining this technique with high resolution intravascular MRI techniques may result in a very useful diagnostic tool for the evaluation of atherosclerosis and other vessel diseases.
KW - Catheter tracking
KW - Interventional MRI
KW - Intravascular MRI
KW - MR fluoroscopy
UR - http://www.scopus.com/inward/record.url?scp=0031785266&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031785266&partnerID=8YFLogxK
U2 - 10.1002/mrm.1910400612
DO - 10.1002/mrm.1910400612
M3 - Article
C2 - 9840831
AN - SCOPUS:0031785266
VL - 40
SP - 865
EP - 872
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
SN - 0740-3194
IS - 6
ER -