Biomechanical advantage of the index-level pedicle screw in unstable thoracolumbar junction fractures: Presented at the 2010 Joint Spine Section Meeting - Laboratory investigation

Ali A. Baaj, Phillip M. Reyes, Ali S. Yaqoobi, Juan S. Uribe, Fernando L. Vale, Nicholas Theodore, Volker K.H. Sonntag, Neil R. Crawford

Research output: Contribution to journalArticlepeer-review

47 Scopus citations

Abstract

Object. Unstable fractures at the thoracolumbar junction often require extended, posterior, segmental pedicular fixation. Some surgeons have reported good clinical outcomes with short-segment constructs if additional pedicle screws are inserted at the fractured level. The goal of this study was to quantify the biomechanical advantage of the index-level screw in a fracture model. Methods. Six human cadaveric T10-L4 specimens were tested. A 3-column injury at L-1 was simulated, and 4 posterior constructs were tested as follows: one-above-one-below (short construct) with/without index-level screws, and two-above-two-below (long construct) with/without index-level screws. Pure moments were applied quasistatically while 3D motion was measured optoelectronically. The range of motion (ROM) and lax zone across T12-L2 were measured during flexion, extension, left and right lateral bending, and left and right axial rotation. Results. All constructs significantly reduced the ROM and lax zone in the fractured specimens. With or without index-level screws, the long-segment constructs provided better immobilization than the short-segment constructs during all loading modes. Adding an index-level screw to the short-segment construct significantly improved stability during flexion and lateral bending; there was no significant improvement in stability when an index-level screw was added to the long-segment construct. Overall, bilateral index-level screws decreased the ROM of the 1-level construct by 25% but decreased the ROM of the 2-level construct by only 3%. Conclusions. In a fracture model, adding index-level pedicle screws to short-segment constructs improves stability, although stability remains less than that provided by long-segment constructs with or without index-level pedicle screws. Therefore, highly unstable fractures likely require extended, long-segment constructs for optimum stability.

Original languageEnglish (US)
Pages (from-to)192-197
Number of pages6
JournalJournal of Neurosurgery: Spine
Volume14
Issue number2
DOIs
StatePublished - Feb 2011
Externally publishedYes

Keywords

  • Biomechanical study
  • Pedicle screw
  • Spine fracture
  • Thoracolumbar junction

ASJC Scopus subject areas

  • Surgery
  • Neurology
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Biomechanical advantage of the index-level pedicle screw in unstable thoracolumbar junction fractures: Presented at the 2010 Joint Spine Section Meeting - Laboratory investigation'. Together they form a unique fingerprint.

Cite this