Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration

Sibyll Goetze, Tracy L. Brown, William C. Lavely, Zhe Zhang, Frank M. Bengel

Research output: Contribution to journalArticle

Abstract

The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/ CT and the performance of a software-based approach for reregistration. Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/ CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 ± 3.8 mm (1.25 ± 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration. Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.

Original languageEnglish (US)
Pages (from-to)1090-1095
Number of pages6
JournalJournal of Nuclear Medicine
Volume48
Issue number7
DOIs
StatePublished - Jul 2007

Fingerprint

Perfusion
Software
Multivariate Analysis
Multimodal Imaging
Myocardial Perfusion Imaging
Single-Photon Emission-Computed Tomography
Individuality
Body Weight
Single Photon Emission Computed Tomography Computed Tomography

Keywords

  • Attenuation correction
  • Hybrid imaging
  • Myocardial perfusion imaging
  • SPECT/CT

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Attenuation correction in myocardial perfusion SPECT/CT : Effects of misregistration and value of reregistration. / Goetze, Sibyll; Brown, Tracy L.; Lavely, William C.; Zhang, Zhe; Bengel, Frank M.

In: Journal of Nuclear Medicine, Vol. 48, No. 7, 07.2007, p. 1090-1095.

Research output: Contribution to journalArticle

Goetze, Sibyll ; Brown, Tracy L. ; Lavely, William C. ; Zhang, Zhe ; Bengel, Frank M. / Attenuation correction in myocardial perfusion SPECT/CT : Effects of misregistration and value of reregistration. In: Journal of Nuclear Medicine. 2007 ; Vol. 48, No. 7. pp. 1090-1095.
@article{740f5e15c3d54e678c194c9e0f2f3e90,
title = "Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration",
abstract = "The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/ CT and the performance of a software-based approach for reregistration. Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/ CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 ± 3.8 mm (1.25 ± 0.55 pixel). Misregistration of one or more pixels was observed in 64{\%} of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration. Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.",
keywords = "Attenuation correction, Hybrid imaging, Myocardial perfusion imaging, SPECT/CT",
author = "Sibyll Goetze and Brown, {Tracy L.} and Lavely, {William C.} and Zhe Zhang and Bengel, {Frank M.}",
year = "2007",
month = "7",
doi = "10.2967/jnumed.107.040535",
language = "English (US)",
volume = "48",
pages = "1090--1095",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "7",

}

TY - JOUR

T1 - Attenuation correction in myocardial perfusion SPECT/CT

T2 - Effects of misregistration and value of reregistration

AU - Goetze, Sibyll

AU - Brown, Tracy L.

AU - Lavely, William C.

AU - Zhang, Zhe

AU - Bengel, Frank M.

PY - 2007/7

Y1 - 2007/7

N2 - The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/ CT and the performance of a software-based approach for reregistration. Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/ CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 ± 3.8 mm (1.25 ± 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration. Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.

AB - The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/ CT and the performance of a software-based approach for reregistration. Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/ CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 ± 3.8 mm (1.25 ± 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration. Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.

KW - Attenuation correction

KW - Hybrid imaging

KW - Myocardial perfusion imaging

KW - SPECT/CT

UR - http://www.scopus.com/inward/record.url?scp=34447313914&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34447313914&partnerID=8YFLogxK

U2 - 10.2967/jnumed.107.040535

DO - 10.2967/jnumed.107.040535

M3 - Article

C2 - 17574985

AN - SCOPUS:34447313914

VL - 48

SP - 1090

EP - 1095

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 7

ER -