Assessment of bias in experimentally measured diffusion tensor imaging parameters using SIMEX

Carolyn B. Lauzon, Ciprian Crainiceanu, Brian C. Caffo, Bennett A. Landman

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

Diffusion tensor imaging enables in vivo investigation of tissue cytoarchitecture through parameter contrasts sensitive to water diffusion barriers at the micrometer level. Parameters are derived through an estimation process that is susceptible to noise and artifacts. Estimated parameters (e.g., fractional anisotropy) exhibit both variability and bias relative to the true parameter value estimated from a hypothetical noise-free acquisition. Herein, we present the use of the simulation and extrapolation (SIMEX) approach for post hoc assessment of bias in a massively univariate imaging setting and evaluate the potential of a SIMEX-based bias correction. Using simulated data with known truth models, spatially varying fractional anisotropy bias error maps are evaluated on two independent and highly differentiated case studies. The stability of SIMEX and its distributional properties are further evaluated on 42 empirical diffusion tensor imaging datasets. Using gradient subsampling, an empirical experiment with a known true outcome is designed and SIMEX performance is compared to the original estimator. With this approach, we find SIMEX bias estimates to be highly accurate offering significant reductions in parameter bias for individual datasets and greater accuracy in averaged population-based estimates.

Original languageEnglish (US)
Pages (from-to)891-902
Number of pages12
JournalMagnetic resonance in medicine
Volume69
Issue number3
DOIs
StatePublished - Mar 1 2013

Keywords

  • bias
  • diffusion tensor imaging
  • fractional anisotropy
  • parameter estimation
  • simulation and extrapolation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Assessment of bias in experimentally measured diffusion tensor imaging parameters using SIMEX'. Together they form a unique fingerprint.

Cite this