Anterior segment imaging predicts incident gonioscopic angle closure

Mani Baskaran, Jayant V. Iyer, Arun K. Narayanaswamy, Yingke He, Lisandro M. Sakata, Renyi Wu, Dianna Liu, Monisha E. Nongpiur, David S. Friedman, Tin Aung

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Purpose To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Design Prospective, observational study. Participants Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. Methods All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Main Outcome Measures Gonioscopic angle closure in 2 or 3 quadrants after 4 years. Results There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Conclusions Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline.

Original languageEnglish (US)
Pages (from-to)2380-2384
Number of pages5
JournalOphthalmology
Volume122
Issue number12
DOIs
StatePublished - Dec 2015

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Anterior segment imaging predicts incident gonioscopic angle closure'. Together they form a unique fingerprint.

Cite this