TY - JOUR
T1 - Analysis of the Transition to Percutaneous Placement of Greenfield Filters
AU - Hye, Robert J.
AU - Mitchell, Alfred T.
AU - Dory, Christopher E.
AU - Freischlag, Julie A.
AU - Roberts, Anne C.
PY - 1990/12
Y1 - 1990/12
N2 - • To establish whether a transition from surgical to percutaneous placement of Greenfield filters was justified, a review of the safety, efficacy, and cost-effectiveness of the two approaches was conducted. Between 1984 and 1989,168 filters were placed in 169 patients, 48 surgically and 120 percutaneously. Placement was successful in 45 (94%) of the 48 surgical patients and 120 (99%) of the 121 percutaneous patients. Filter misplacement occurred in three (6%) surgical patients and no percutaneous patients. Clinically evident femoral vein thrombosis occurred in only four (5%) of the percutaneous patients, while inferior vena cava thrombosis occurred in three (3%) of the percutaneous patients. One pulmonary embolus occurred after percutaneous filter placement and resulted in death. The cost of percutaneous placement was 58% that of surgical placement. A retrospective review of the experience in our patient population indicates that safety, cost, and ease of insertion make the percutaneous approach the procedure of choice for Greenfield filter placement.
AB - • To establish whether a transition from surgical to percutaneous placement of Greenfield filters was justified, a review of the safety, efficacy, and cost-effectiveness of the two approaches was conducted. Between 1984 and 1989,168 filters were placed in 169 patients, 48 surgically and 120 percutaneously. Placement was successful in 45 (94%) of the 48 surgical patients and 120 (99%) of the 121 percutaneous patients. Filter misplacement occurred in three (6%) surgical patients and no percutaneous patients. Clinically evident femoral vein thrombosis occurred in only four (5%) of the percutaneous patients, while inferior vena cava thrombosis occurred in three (3%) of the percutaneous patients. One pulmonary embolus occurred after percutaneous filter placement and resulted in death. The cost of percutaneous placement was 58% that of surgical placement. A retrospective review of the experience in our patient population indicates that safety, cost, and ease of insertion make the percutaneous approach the procedure of choice for Greenfield filter placement.
UR - http://www.scopus.com/inward/record.url?scp=0025248366&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025248366&partnerID=8YFLogxK
U2 - 10.1001/archsurg.1990.01410240028005
DO - 10.1001/archsurg.1990.01410240028005
M3 - Article
C2 - 2123085
AN - SCOPUS:0025248366
SN - 2168-6254
VL - 125
SP - 1550
EP - 1553
JO - JAMA Surgery
JF - JAMA Surgery
IS - 12
ER -