Abdominal MR imaging

Comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging

Russell N. Low, Isaac R. Francis, Joel S. Sigeti, Thomas K F Foo

Research output: Contribution to journalArticle

Abstract

T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium-enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast-to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90% with fast SE and was 85% and 80% for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.

Original languageEnglish (US)
Pages (from-to)803-811
Number of pages9
JournalRadiology
Volume186
Issue number3
StatePublished - Mar 1993
Externally publishedYes

Fingerprint

Gadolinium
Liver
Artifacts
Contrast Media
Noise
Magnetic Resonance Imaging

Keywords

  • Abdomen, MR, 70.121411, 70.121412, 70.121416
  • Liver neoplasms, 761.30
  • Liver neoplasms, MR, 761.30
  • Magnetic resonance (MR), contrast enhancement
  • Magnetic resonance (MR), pulse sequences
  • Magnetic resonance (MR), rapid imaging

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Abdominal MR imaging : Comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging. / Low, Russell N.; Francis, Isaac R.; Sigeti, Joel S.; Foo, Thomas K F.

In: Radiology, Vol. 186, No. 3, 03.1993, p. 803-811.

Research output: Contribution to journalArticle

Low, Russell N. ; Francis, Isaac R. ; Sigeti, Joel S. ; Foo, Thomas K F. / Abdominal MR imaging : Comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging. In: Radiology. 1993 ; Vol. 186, No. 3. pp. 803-811.
@article{db13683566144363b54e0937cb309bd0,
title = "Abdominal MR imaging: Comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging",
abstract = "T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium-enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast-to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90{\%} with fast SE and was 85{\%} and 80{\%} for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.",
keywords = "Abdomen, MR, 70.121411, 70.121412, 70.121416, Liver neoplasms, 761.30, Liver neoplasms, MR, 761.30, Magnetic resonance (MR), contrast enhancement, Magnetic resonance (MR), pulse sequences, Magnetic resonance (MR), rapid imaging",
author = "Low, {Russell N.} and Francis, {Isaac R.} and Sigeti, {Joel S.} and Foo, {Thomas K F}",
year = "1993",
month = "3",
language = "English (US)",
volume = "186",
pages = "803--811",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "3",

}

TY - JOUR

T1 - Abdominal MR imaging

T2 - Comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging

AU - Low, Russell N.

AU - Francis, Isaac R.

AU - Sigeti, Joel S.

AU - Foo, Thomas K F

PY - 1993/3

Y1 - 1993/3

N2 - T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium-enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast-to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90% with fast SE and was 85% and 80% for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.

AB - T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium-enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast-to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90% with fast SE and was 85% and 80% for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.

KW - Abdomen, MR, 70.121411, 70.121412, 70.121416

KW - Liver neoplasms, 761.30

KW - Liver neoplasms, MR, 761.30

KW - Magnetic resonance (MR), contrast enhancement

KW - Magnetic resonance (MR), pulse sequences

KW - Magnetic resonance (MR), rapid imaging

UR - http://www.scopus.com/inward/record.url?scp=0027452674&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027452674&partnerID=8YFLogxK

M3 - Article

VL - 186

SP - 803

EP - 811

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 3

ER -