TY - JOUR
T1 - A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized 3He MRI
AU - Hamedani, Hooman
AU - Kadlecek, Stephen J.
AU - Ishii, Masaru
AU - Emami, Kiarash
AU - Kuzma, Nicholas N.
AU - Xin, Yi
AU - Rossman, Milton
AU - Rizi, Rahim R.
PY - 2013/12
Y1 - 2013/12
N2 - Purpose A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pAO 2) measurements using 3He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated p AO2 was compared with that of the standard pulmonary function tests. Methods Pulmonary function test and pAO2 imaging were performed on 4 nonsmokers (1 M, 3 F, 56 ± 1.7 years) and 4 smokers (3 M, 1 F, 52 ± 7.5 years) during three visits over the course of 2 weeks. Two measurements were performed per visit. Variability of p AO2 was assessed using a mixed-effect model, with an intraclass correlation coefficient calculated for each group. The coefficient of variation of pAO2 over the 3-day period was also compared with the coefficient of variation of pulmonary function test results. Results Short-term regional variability based on intraclass correlation coefficient was 0.71 for nonsmokers, and 0.63 for smokers, with long-term variability significantly lower at 0.59 and 0.47, respectively. While the coefficient of variation of the average pAO2 was similar to the repeatability of the diffusing capacity of CO, it was significantly higher than that of Forced Vital Capacity (P = 0.02). Conclusion Short-term and long-term pAO2 variability differences were used as an indication of true physiological changes in order to measure technical reproducibility. Smokers show higher physiologic variability and less technical reproducibility. The suggested pAO2-imaging technique showed a reasonable regional repeatability in nonsmokers as well as the ability to detect differences between the two groups with similar reproducibility and superior discriminatory ability when compared with pulmonary function tests. Magn Reson Med 70:1557-1566, 2013. © 2013 Wiley Periodicals, Inc.
AB - Purpose A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pAO 2) measurements using 3He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated p AO2 was compared with that of the standard pulmonary function tests. Methods Pulmonary function test and pAO2 imaging were performed on 4 nonsmokers (1 M, 3 F, 56 ± 1.7 years) and 4 smokers (3 M, 1 F, 52 ± 7.5 years) during three visits over the course of 2 weeks. Two measurements were performed per visit. Variability of p AO2 was assessed using a mixed-effect model, with an intraclass correlation coefficient calculated for each group. The coefficient of variation of pAO2 over the 3-day period was also compared with the coefficient of variation of pulmonary function test results. Results Short-term regional variability based on intraclass correlation coefficient was 0.71 for nonsmokers, and 0.63 for smokers, with long-term variability significantly lower at 0.59 and 0.47, respectively. While the coefficient of variation of the average pAO2 was similar to the repeatability of the diffusing capacity of CO, it was significantly higher than that of Forced Vital Capacity (P = 0.02). Conclusion Short-term and long-term pAO2 variability differences were used as an indication of true physiological changes in order to measure technical reproducibility. Smokers show higher physiologic variability and less technical reproducibility. The suggested pAO2-imaging technique showed a reasonable regional repeatability in nonsmokers as well as the ability to detect differences between the two groups with similar reproducibility and superior discriminatory ability when compared with pulmonary function tests. Magn Reson Med 70:1557-1566, 2013. © 2013 Wiley Periodicals, Inc.
KW - 3He MRI
KW - alveolar oxygen tension
KW - reproducibility
UR - http://www.scopus.com/inward/record.url?scp=84888010386&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84888010386&partnerID=8YFLogxK
U2 - 10.1002/mrm.24604
DO - 10.1002/mrm.24604
M3 - Article
C2 - 23382040
AN - SCOPUS:84888010386
SN - 0740-3194
VL - 70
SP - 1557
EP - 1566
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 6
ER -