A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall

Maithili Sharan, Aleksander S Popel

Research output: Contribution to journalArticle

Abstract

A two-phase model for the flow of blood in narrow tubes is described. The model consists of a central core of suspended erythrocytes and a cell-free layer surrounding the core. It is assumed that the viscosity in the cell-free layer differs from that of plasma as a result of additional dissipation of energy near the wall caused by the red blood cell motion near the cell-free layer. A consistent system of nonlinear equations is solved numerically to estimate: (i) the effective dimensionless viscosity in the cell-free layer (β), (ii) thickness of the cell-free layer (1 - λ) and (iii) core hematocrit (Hc). We have taken the variation of apparent viscosity (μapp) and tube hematocrit with the tube diameter (D) and the discharge hematocrit (HD) from in vitro experimental studies [16]. The thickness of the cell-free layer computed from the model is found to be in agreement with the observations [3,21]. Sensitivity analysis has been carried out to study the behavior of the parameters 1 - λ, β, Hc, B (bluntness of the velocity profile) and μapp with the variation of D and HD.

Original languageEnglish (US)
Pages (from-to)415-428
Number of pages14
JournalBiorheology
Volume38
Issue number5-6
StatePublished - 2001

Fingerprint

Viscosity
Hematocrit
Erythrocytes

Keywords

  • Bluntness
  • Energy dissipation
  • Mathematical model
  • Relative viscosity
  • Two-phase blood flow

ASJC Scopus subject areas

  • Medicine(all)

Cite this

A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall. / Sharan, Maithili; Popel, Aleksander S.

In: Biorheology, Vol. 38, No. 5-6, 2001, p. 415-428.

Research output: Contribution to journalArticle

@article{f3b749c38b174bd0a2584eff03c907d3,
title = "A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall",
abstract = "A two-phase model for the flow of blood in narrow tubes is described. The model consists of a central core of suspended erythrocytes and a cell-free layer surrounding the core. It is assumed that the viscosity in the cell-free layer differs from that of plasma as a result of additional dissipation of energy near the wall caused by the red blood cell motion near the cell-free layer. A consistent system of nonlinear equations is solved numerically to estimate: (i) the effective dimensionless viscosity in the cell-free layer (β), (ii) thickness of the cell-free layer (1 - λ) and (iii) core hematocrit (Hc). We have taken the variation of apparent viscosity (μapp) and tube hematocrit with the tube diameter (D) and the discharge hematocrit (HD) from in vitro experimental studies [16]. The thickness of the cell-free layer computed from the model is found to be in agreement with the observations [3,21]. Sensitivity analysis has been carried out to study the behavior of the parameters 1 - λ, β, Hc, B (bluntness of the velocity profile) and μapp with the variation of D and HD.",
keywords = "Bluntness, Energy dissipation, Mathematical model, Relative viscosity, Two-phase blood flow",
author = "Maithili Sharan and Popel, {Aleksander S}",
year = "2001",
language = "English (US)",
volume = "38",
pages = "415--428",
journal = "Biorheology",
issn = "0006-355X",
publisher = "IOS Press",
number = "5-6",

}

TY - JOUR

T1 - A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall

AU - Sharan, Maithili

AU - Popel, Aleksander S

PY - 2001

Y1 - 2001

N2 - A two-phase model for the flow of blood in narrow tubes is described. The model consists of a central core of suspended erythrocytes and a cell-free layer surrounding the core. It is assumed that the viscosity in the cell-free layer differs from that of plasma as a result of additional dissipation of energy near the wall caused by the red blood cell motion near the cell-free layer. A consistent system of nonlinear equations is solved numerically to estimate: (i) the effective dimensionless viscosity in the cell-free layer (β), (ii) thickness of the cell-free layer (1 - λ) and (iii) core hematocrit (Hc). We have taken the variation of apparent viscosity (μapp) and tube hematocrit with the tube diameter (D) and the discharge hematocrit (HD) from in vitro experimental studies [16]. The thickness of the cell-free layer computed from the model is found to be in agreement with the observations [3,21]. Sensitivity analysis has been carried out to study the behavior of the parameters 1 - λ, β, Hc, B (bluntness of the velocity profile) and μapp with the variation of D and HD.

AB - A two-phase model for the flow of blood in narrow tubes is described. The model consists of a central core of suspended erythrocytes and a cell-free layer surrounding the core. It is assumed that the viscosity in the cell-free layer differs from that of plasma as a result of additional dissipation of energy near the wall caused by the red blood cell motion near the cell-free layer. A consistent system of nonlinear equations is solved numerically to estimate: (i) the effective dimensionless viscosity in the cell-free layer (β), (ii) thickness of the cell-free layer (1 - λ) and (iii) core hematocrit (Hc). We have taken the variation of apparent viscosity (μapp) and tube hematocrit with the tube diameter (D) and the discharge hematocrit (HD) from in vitro experimental studies [16]. The thickness of the cell-free layer computed from the model is found to be in agreement with the observations [3,21]. Sensitivity analysis has been carried out to study the behavior of the parameters 1 - λ, β, Hc, B (bluntness of the velocity profile) and μapp with the variation of D and HD.

KW - Bluntness

KW - Energy dissipation

KW - Mathematical model

KW - Relative viscosity

KW - Two-phase blood flow

UR - http://www.scopus.com/inward/record.url?scp=0035738371&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035738371&partnerID=8YFLogxK

M3 - Article

VL - 38

SP - 415

EP - 428

JO - Biorheology

JF - Biorheology

SN - 0006-355X

IS - 5-6

ER -