A pulsed time-of-flight mass spectrometer for liquid secondary ion mass spectrometry.

J. K. Olthoff, I. A. Lys, Robert J. Cotter

Research output: Contribution to journalArticle

Abstract

The design and performance of a new time-of-flight mass spectrometer is reported. The instrument combines the advantages of a pulsed drawout TOF analyzer with a liquid secondary ion source. Differences from commercially available pulsed TOF analyzers (Wiley/McLaren type) are discussed with regard to operation with ion desorption from a liquid matrix.

Original languageEnglish (US)
Pages (from-to)171-175
Number of pages5
JournalRapid communications in mass spectrometry : RCM
Volume2
Issue number9
StatePublished - Sep 1988

Fingerprint

Mass spectrometers
Secondary ion mass spectrometry
Liquids
Ion sources
Desorption
Ions

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

A pulsed time-of-flight mass spectrometer for liquid secondary ion mass spectrometry. / Olthoff, J. K.; Lys, I. A.; Cotter, Robert J.

In: Rapid communications in mass spectrometry : RCM, Vol. 2, No. 9, 09.1988, p. 171-175.

Research output: Contribution to journalArticle

@article{317f31aa99164041a1de976ca96d3958,
title = "A pulsed time-of-flight mass spectrometer for liquid secondary ion mass spectrometry.",
abstract = "The design and performance of a new time-of-flight mass spectrometer is reported. The instrument combines the advantages of a pulsed drawout TOF analyzer with a liquid secondary ion source. Differences from commercially available pulsed TOF analyzers (Wiley/McLaren type) are discussed with regard to operation with ion desorption from a liquid matrix.",
author = "Olthoff, {J. K.} and Lys, {I. A.} and Cotter, {Robert J.}",
year = "1988",
month = "9",
language = "English (US)",
volume = "2",
pages = "171--175",
journal = "Rapid Communications in Mass Spectrometry",
issn = "0951-4198",
publisher = "John Wiley and Sons Ltd",
number = "9",

}

TY - JOUR

T1 - A pulsed time-of-flight mass spectrometer for liquid secondary ion mass spectrometry.

AU - Olthoff, J. K.

AU - Lys, I. A.

AU - Cotter, Robert J.

PY - 1988/9

Y1 - 1988/9

N2 - The design and performance of a new time-of-flight mass spectrometer is reported. The instrument combines the advantages of a pulsed drawout TOF analyzer with a liquid secondary ion source. Differences from commercially available pulsed TOF analyzers (Wiley/McLaren type) are discussed with regard to operation with ion desorption from a liquid matrix.

AB - The design and performance of a new time-of-flight mass spectrometer is reported. The instrument combines the advantages of a pulsed drawout TOF analyzer with a liquid secondary ion source. Differences from commercially available pulsed TOF analyzers (Wiley/McLaren type) are discussed with regard to operation with ion desorption from a liquid matrix.

UR - http://www.scopus.com/inward/record.url?scp=0024067778&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024067778&partnerID=8YFLogxK

M3 - Article

C2 - 2577850

AN - SCOPUS:0024067778

VL - 2

SP - 171

EP - 175

JO - Rapid Communications in Mass Spectrometry

JF - Rapid Communications in Mass Spectrometry

SN - 0951-4198

IS - 9

ER -