Abstract

Since the publication of previous meta-analyses of cyclosporine (CsA) and prednisone withdrawal in renal transplant recipients, several additional randomized controlled trials with longer follow-up have been reported. Currently, in nine prednisone withdrawal trials (n = 1461), the proportion of patients with acute rejection was increased by 0.14 (95% confidence interval = 0.10 to 0.17, P < 0.001). In nine prednisone withdrawal trials (n = 1899), the relative risk (RR; RR = 1.0 indicates no risk) of graft failure after withdrawal was also increased (RR = 1.40; range, 1.09 to 1.70, P = 0.012). There was no evidence of between-study heterogeneity for either acute rejection or graft failure in the prednisone withdrawal trials by a X2 test (P > 0.05). In 10 CsA withdrawal trials (n = 1049), the proportion of patients with acute rejection was increased by 0.11 (0.07 to 0.15, P < 0.001). In 12 trials (n = 1151), the RR of graft failure after CsA withdrawal was 1.06 (95% confidence interval, 0.82 to 1.29, P = 0.646), but a X2 test indicated that there was study heterogeneity. However, there was no evidence of heterogeneity in the six studies (n = 632) with at least 4.0 yr (5.8 ± 1.7) of follow-up (RR = 0.92; range, 0.64 to 1.20, P = 0.569) or in the seven trials (n = 962) published in peer-reviewed journals (RR = 0.95; range, 0.70 to 1.20, P = 0.682). Finally, in three trials (n = 259) that compared CsA and prednisone withdrawal, there was a nonsignificant trend for less graft failure with CsA withdrawal (RR = 0.63; range, 0.08 to 1.16, P = 0.190). Thus, unlike prednisone withdrawal, CsA withdrawal in select patients seems to impart little risk of long-term graft failure.

Original languageEnglish (US)
Pages (from-to)1910-1917
Number of pages8
JournalJournal of the American Society of Nephrology
Volume11
Issue number10
StatePublished - 2000
Externally publishedYes

Fingerprint

Prednisone
Kidney Transplantation
Immunosuppression
Meta-Analysis
Transplants
Confidence Intervals
Cyclosporine
Publications
Randomized Controlled Trials
Kidney

ASJC Scopus subject areas

  • Nephrology

Cite this

A meta-analysis of immunosuppression withdrawal trials in renal transplantation. / Kasiske, Bertram L.; Chakkera, Harini A.; Louis, Thomas; Ma, Jennie Z.

In: Journal of the American Society of Nephrology, Vol. 11, No. 10, 2000, p. 1910-1917.

Research output: Contribution to journalArticle

Kasiske, Bertram L. ; Chakkera, Harini A. ; Louis, Thomas ; Ma, Jennie Z. / A meta-analysis of immunosuppression withdrawal trials in renal transplantation. In: Journal of the American Society of Nephrology. 2000 ; Vol. 11, No. 10. pp. 1910-1917.
@article{6b78b561bf974b579a6e6f8324703ddd,
title = "A meta-analysis of immunosuppression withdrawal trials in renal transplantation",
abstract = "Since the publication of previous meta-analyses of cyclosporine (CsA) and prednisone withdrawal in renal transplant recipients, several additional randomized controlled trials with longer follow-up have been reported. Currently, in nine prednisone withdrawal trials (n = 1461), the proportion of patients with acute rejection was increased by 0.14 (95{\%} confidence interval = 0.10 to 0.17, P < 0.001). In nine prednisone withdrawal trials (n = 1899), the relative risk (RR; RR = 1.0 indicates no risk) of graft failure after withdrawal was also increased (RR = 1.40; range, 1.09 to 1.70, P = 0.012). There was no evidence of between-study heterogeneity for either acute rejection or graft failure in the prednisone withdrawal trials by a X2 test (P > 0.05). In 10 CsA withdrawal trials (n = 1049), the proportion of patients with acute rejection was increased by 0.11 (0.07 to 0.15, P < 0.001). In 12 trials (n = 1151), the RR of graft failure after CsA withdrawal was 1.06 (95{\%} confidence interval, 0.82 to 1.29, P = 0.646), but a X2 test indicated that there was study heterogeneity. However, there was no evidence of heterogeneity in the six studies (n = 632) with at least 4.0 yr (5.8 ± 1.7) of follow-up (RR = 0.92; range, 0.64 to 1.20, P = 0.569) or in the seven trials (n = 962) published in peer-reviewed journals (RR = 0.95; range, 0.70 to 1.20, P = 0.682). Finally, in three trials (n = 259) that compared CsA and prednisone withdrawal, there was a nonsignificant trend for less graft failure with CsA withdrawal (RR = 0.63; range, 0.08 to 1.16, P = 0.190). Thus, unlike prednisone withdrawal, CsA withdrawal in select patients seems to impart little risk of long-term graft failure.",
author = "Kasiske, {Bertram L.} and Chakkera, {Harini A.} and Thomas Louis and Ma, {Jennie Z.}",
year = "2000",
language = "English (US)",
volume = "11",
pages = "1910--1917",
journal = "Journal of the American Society of Nephrology : JASN",
issn = "1046-6673",
publisher = "American Society of Nephrology",
number = "10",

}

TY - JOUR

T1 - A meta-analysis of immunosuppression withdrawal trials in renal transplantation

AU - Kasiske, Bertram L.

AU - Chakkera, Harini A.

AU - Louis, Thomas

AU - Ma, Jennie Z.

PY - 2000

Y1 - 2000

N2 - Since the publication of previous meta-analyses of cyclosporine (CsA) and prednisone withdrawal in renal transplant recipients, several additional randomized controlled trials with longer follow-up have been reported. Currently, in nine prednisone withdrawal trials (n = 1461), the proportion of patients with acute rejection was increased by 0.14 (95% confidence interval = 0.10 to 0.17, P < 0.001). In nine prednisone withdrawal trials (n = 1899), the relative risk (RR; RR = 1.0 indicates no risk) of graft failure after withdrawal was also increased (RR = 1.40; range, 1.09 to 1.70, P = 0.012). There was no evidence of between-study heterogeneity for either acute rejection or graft failure in the prednisone withdrawal trials by a X2 test (P > 0.05). In 10 CsA withdrawal trials (n = 1049), the proportion of patients with acute rejection was increased by 0.11 (0.07 to 0.15, P < 0.001). In 12 trials (n = 1151), the RR of graft failure after CsA withdrawal was 1.06 (95% confidence interval, 0.82 to 1.29, P = 0.646), but a X2 test indicated that there was study heterogeneity. However, there was no evidence of heterogeneity in the six studies (n = 632) with at least 4.0 yr (5.8 ± 1.7) of follow-up (RR = 0.92; range, 0.64 to 1.20, P = 0.569) or in the seven trials (n = 962) published in peer-reviewed journals (RR = 0.95; range, 0.70 to 1.20, P = 0.682). Finally, in three trials (n = 259) that compared CsA and prednisone withdrawal, there was a nonsignificant trend for less graft failure with CsA withdrawal (RR = 0.63; range, 0.08 to 1.16, P = 0.190). Thus, unlike prednisone withdrawal, CsA withdrawal in select patients seems to impart little risk of long-term graft failure.

AB - Since the publication of previous meta-analyses of cyclosporine (CsA) and prednisone withdrawal in renal transplant recipients, several additional randomized controlled trials with longer follow-up have been reported. Currently, in nine prednisone withdrawal trials (n = 1461), the proportion of patients with acute rejection was increased by 0.14 (95% confidence interval = 0.10 to 0.17, P < 0.001). In nine prednisone withdrawal trials (n = 1899), the relative risk (RR; RR = 1.0 indicates no risk) of graft failure after withdrawal was also increased (RR = 1.40; range, 1.09 to 1.70, P = 0.012). There was no evidence of between-study heterogeneity for either acute rejection or graft failure in the prednisone withdrawal trials by a X2 test (P > 0.05). In 10 CsA withdrawal trials (n = 1049), the proportion of patients with acute rejection was increased by 0.11 (0.07 to 0.15, P < 0.001). In 12 trials (n = 1151), the RR of graft failure after CsA withdrawal was 1.06 (95% confidence interval, 0.82 to 1.29, P = 0.646), but a X2 test indicated that there was study heterogeneity. However, there was no evidence of heterogeneity in the six studies (n = 632) with at least 4.0 yr (5.8 ± 1.7) of follow-up (RR = 0.92; range, 0.64 to 1.20, P = 0.569) or in the seven trials (n = 962) published in peer-reviewed journals (RR = 0.95; range, 0.70 to 1.20, P = 0.682). Finally, in three trials (n = 259) that compared CsA and prednisone withdrawal, there was a nonsignificant trend for less graft failure with CsA withdrawal (RR = 0.63; range, 0.08 to 1.16, P = 0.190). Thus, unlike prednisone withdrawal, CsA withdrawal in select patients seems to impart little risk of long-term graft failure.

UR - http://www.scopus.com/inward/record.url?scp=0033774719&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033774719&partnerID=8YFLogxK

M3 - Article

C2 - 11004223

AN - SCOPUS:0033774719

VL - 11

SP - 1910

EP - 1917

JO - Journal of the American Society of Nephrology : JASN

JF - Journal of the American Society of Nephrology : JASN

SN - 1046-6673

IS - 10

ER -