A comparison of methods of repairing the symphysis pubis in bladder exstrophy by tensile testing

J. S. Sussman, Paul David Sponseller, John Phillip Gearhart, A. D C Valdevit, J. Kier-York, E. Y S Chao

Research output: Contribution to journalArticle

Abstract

Objective. To compare the efficacy of several fixation techniques in the reconstruction of diastasis of the symphysis pubis in bladder exstrophy. Materials and methods. The symphyses of 32 pelves removed from piglets about 1 month old were disrupted and repaired using one of eight methods. After repair, each pelvis was tested biomechanically for load-to-failure, stiffness and energy-to-failure. The various repair techniques were compared with one another and to a group of six pelves tested intact. Results. Four of the methods tested, including a no. 2 nylon suture placed through bone in a horizontal mattress arrangement, several loops of no. 2 nylon suture tied around the pubes, Mersilene tape tied around the pubes, and Mitek G-II suture anchors placed into the superior pubic rami, showed the highest stiffness and load-to-failure. All methods were very weak compared with the intact symphysis; the best load-to-failure (no. 2 nylon horizontal mattress suture) was less than half of that for intact bone, and the best stiffness (mersilene tape) was less than one-third that for the intact symphysis. Conclusion. The repairs varied greatly in the variables tested and those which are most promising merit further investigation to assess methods of improving their performance.

Original languageEnglish (US)
Pages (from-to)979-984
Number of pages6
JournalBritish Journal of Urology
Volume79
Issue number6
StatePublished - 1997
Externally publishedYes

Fingerprint

Pubic Bone
Bladder Exstrophy
Nylons
Pelvis
Sutures
Pubic Symphysis Diastasis
Suture Anchors
Bone and Bones

Keywords

  • Bladder exstrophy
  • Bone
  • Osteotomy
  • Pelvis
  • Repair
  • Suture

ASJC Scopus subject areas

  • Urology

Cite this

A comparison of methods of repairing the symphysis pubis in bladder exstrophy by tensile testing. / Sussman, J. S.; Sponseller, Paul David; Gearhart, John Phillip; Valdevit, A. D C; Kier-York, J.; Chao, E. Y S.

In: British Journal of Urology, Vol. 79, No. 6, 1997, p. 979-984.

Research output: Contribution to journalArticle

@article{3d0d06807bed4d699843710d9a4b6e76,
title = "A comparison of methods of repairing the symphysis pubis in bladder exstrophy by tensile testing",
abstract = "Objective. To compare the efficacy of several fixation techniques in the reconstruction of diastasis of the symphysis pubis in bladder exstrophy. Materials and methods. The symphyses of 32 pelves removed from piglets about 1 month old were disrupted and repaired using one of eight methods. After repair, each pelvis was tested biomechanically for load-to-failure, stiffness and energy-to-failure. The various repair techniques were compared with one another and to a group of six pelves tested intact. Results. Four of the methods tested, including a no. 2 nylon suture placed through bone in a horizontal mattress arrangement, several loops of no. 2 nylon suture tied around the pubes, Mersilene tape tied around the pubes, and Mitek G-II suture anchors placed into the superior pubic rami, showed the highest stiffness and load-to-failure. All methods were very weak compared with the intact symphysis; the best load-to-failure (no. 2 nylon horizontal mattress suture) was less than half of that for intact bone, and the best stiffness (mersilene tape) was less than one-third that for the intact symphysis. Conclusion. The repairs varied greatly in the variables tested and those which are most promising merit further investigation to assess methods of improving their performance.",
keywords = "Bladder exstrophy, Bone, Osteotomy, Pelvis, Repair, Suture",
author = "Sussman, {J. S.} and Sponseller, {Paul David} and Gearhart, {John Phillip} and Valdevit, {A. D C} and J. Kier-York and Chao, {E. Y S}",
year = "1997",
language = "English (US)",
volume = "79",
pages = "979--984",
journal = "BJU International",
issn = "1464-4096",
publisher = "Wiley-Blackwell",
number = "6",

}

TY - JOUR

T1 - A comparison of methods of repairing the symphysis pubis in bladder exstrophy by tensile testing

AU - Sussman, J. S.

AU - Sponseller, Paul David

AU - Gearhart, John Phillip

AU - Valdevit, A. D C

AU - Kier-York, J.

AU - Chao, E. Y S

PY - 1997

Y1 - 1997

N2 - Objective. To compare the efficacy of several fixation techniques in the reconstruction of diastasis of the symphysis pubis in bladder exstrophy. Materials and methods. The symphyses of 32 pelves removed from piglets about 1 month old were disrupted and repaired using one of eight methods. After repair, each pelvis was tested biomechanically for load-to-failure, stiffness and energy-to-failure. The various repair techniques were compared with one another and to a group of six pelves tested intact. Results. Four of the methods tested, including a no. 2 nylon suture placed through bone in a horizontal mattress arrangement, several loops of no. 2 nylon suture tied around the pubes, Mersilene tape tied around the pubes, and Mitek G-II suture anchors placed into the superior pubic rami, showed the highest stiffness and load-to-failure. All methods were very weak compared with the intact symphysis; the best load-to-failure (no. 2 nylon horizontal mattress suture) was less than half of that for intact bone, and the best stiffness (mersilene tape) was less than one-third that for the intact symphysis. Conclusion. The repairs varied greatly in the variables tested and those which are most promising merit further investigation to assess methods of improving their performance.

AB - Objective. To compare the efficacy of several fixation techniques in the reconstruction of diastasis of the symphysis pubis in bladder exstrophy. Materials and methods. The symphyses of 32 pelves removed from piglets about 1 month old were disrupted and repaired using one of eight methods. After repair, each pelvis was tested biomechanically for load-to-failure, stiffness and energy-to-failure. The various repair techniques were compared with one another and to a group of six pelves tested intact. Results. Four of the methods tested, including a no. 2 nylon suture placed through bone in a horizontal mattress arrangement, several loops of no. 2 nylon suture tied around the pubes, Mersilene tape tied around the pubes, and Mitek G-II suture anchors placed into the superior pubic rami, showed the highest stiffness and load-to-failure. All methods were very weak compared with the intact symphysis; the best load-to-failure (no. 2 nylon horizontal mattress suture) was less than half of that for intact bone, and the best stiffness (mersilene tape) was less than one-third that for the intact symphysis. Conclusion. The repairs varied greatly in the variables tested and those which are most promising merit further investigation to assess methods of improving their performance.

KW - Bladder exstrophy

KW - Bone

KW - Osteotomy

KW - Pelvis

KW - Repair

KW - Suture

UR - http://www.scopus.com/inward/record.url?scp=0031396831&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031396831&partnerID=8YFLogxK

M3 - Article

C2 - 9202570

AN - SCOPUS:0031396831

VL - 79

SP - 979

EP - 984

JO - BJU International

JF - BJU International

SN - 1464-4096

IS - 6

ER -